Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nonlinear Guided Waves and Their Applications

Squeezed States, Parametric Interactions and Fundamental Noise Sources in Optical Fibers

Robert M. Shelby, M. D. Levenson

Published Jan 1, 1989• 0 citations
Publisher

Abstract

Well-stabilized lasers emit radiation that is a close approximation to a coherent state: a classical mean field which varies sinusoidally in time at optical frequency ω0, superposed with broad-band noise fields due to the field's quantum uncertainty in its ground state (i.e. vacuum fluctuations). When detected by a standard photodetector, the interference between these vacuum fields and the coherent mean field causes the noise floor commonly referred to as the "shot-noise limit." The vacuum noise also causes fluctuations in the phase of the beam that are independent and uncorrelated with the amplitude fluctuations, and to which photodetectors are insensitive. The amplitude and phase fluctuations of the field can be represented by quadrature amplitudes X ^ A ( δ ) and X ^ ϕ ( δ ) which are the Fourier components of amplitude and phase modulation or fluctuation at a particular modulation frequency δ. These quadrature amplitudes are non-commuting quantum observables which obey the uncertainty principle.

DOI
10.1364/nlgwp.1989.sa1

Related papers

Quantum Optics And Nonlinear Interactions In Optical Fibers

Robert M. Shelby, M. D. Levenson

A stabilized laser emits a light beam in a coherent state: a light field with properties very similar to a classical field, but with quantum zero-point fluctuations (vacuum noise) of the field superposed. The nonlinear refractive index of optical fibers can be used to alter the quantum statistics of the light to produce a beam with non-classical properties: a squeezed state. Upon detection, squeezed states exhibit a noise level which is phase-dependent and which can be well below the coherent state level ("shot-noise limit"). The nonlinear refractive index also provides a means for experimental demonstration of the related concept of "quantum non-demolition detection": The measurement of a quantum observable without adding uncertainty to that variable.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 1, 1987•0 citations

Nonclassical Excitation in Spectroscopy with Squeezed Light

Z. Ficek, P. D. Drummond

The amplitude and phase of all light fields are subject to fluctuations. Much of this irregularity arises from random and uncontrolled changes that occur in any light source and lead to random changes in the light wave's frequency and amplitude. Most of these factors can in principle be eliminated by a careful design of the light source. Even if all of these defects in the source are removed, however, light fields are still subject to fluctuations arising from the laws of quantum mechanics. Even in a highly stabilized laser, the resulting coherent electromagnetic field has an uncertainty in the phase and magnitude of its amplitude. All conventional sources of light fields have at least this noise level, which, in a fully quantum description, arises from vacuum fluctuations. At one time it was believed that this vacuum or coherent-state noise could not be eliminated.

Physics Today•Sep 1, 1997•17 citations

“SQUEEZING” OF CLASSICAL AMPLITUDE AND PHASE FLUCTUATIONS BY NON-DEGENERATE FOUR WAVE MIXING IN AN OPTICAL FIBER

M. D. Levenson, Robert M. Shelby, Stephen H. Perlmutter

Parametric interactions such as four wave mixing have been predicted to produce states of the radiation field where the quantum fluctuations in one phase quadrature are less than those of a coherent state.1 These “squeezed states” have proved remarkably difficult to generate and detect, not least because of the presence of additional classical noise in many laser sources and parametric devices. We have now demonstrated the reduction of classical fluctuations by means of four wave mixing in an optical fiber under conditions very similar to those needed to demonstrate squeezed state generation. This success reinforces the plausibility of related quantum noise experiments, and has implications for fiber optic communications.

Conference on Lasers and Electro-Optics•Jan 1, 1985•0 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations

Intensity noise correlation in a triply resonant optical parametric oscillator

Joseph Teja

Shot NoiseSince the observation of quantum noise is made in the context of photodetector measureinents, it is appropriate to begin by briefly reviewing the concept of noise in general, and the origin of shot noise in photodetection.Noise represents random electromagnetic fields occupying the same spectral region as that occupied by some "signal".With regard to the measurement of optical power, noise causes fluctuations in the measurement, thus placing a lower limit on the smallest amount of power that can be measured.In most situations, the sources of noise are due to the concerted action of a large number of independent agents.In this case the central limit theorem of statistics [35] tells us that the noise is described by a Gaussian distribution with zero mean and a mean square variance r 2 .Time averaged noise power is proportional to this mean square value, or the statistical variance of random fluctuations.For a given observable quantity A, we will use the notation (A) -14 - Chapter 1Photodetectors produce an electric current proportional to the incident radiation, or photon flux, via generation of carriers in a semiconductor.These detectors are characterized by a quantum efficiency which expresses the ratio of the rate of -15 -Chapter 1 spectral density function of a train of randomly occurring electron emission events and the Fourier transform of a single current pulse between the two electrodes of the photodetector [41], and is typically given in terms of the mean square current -16 -Chapter 1 'For two quantum operators, A and B, with a commutator [A, B] = iC, the uncertainty principle states that AA 2 AB 2 > _I(CoI2.From [26].-18 -Chapter 1Even in complete darkness (c) there must be some quantum uncertainty, and so the field strengths are not exactly zero; they too fluctuate within an envelope of uncertainty.From [33].

•Jan 1, 1997•0 citations

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier +2 more

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

Topical Meeting on Quantum-Limited Imaging and Image Processing•Jan 1, 1989•0 citations
Well-stabilized lasers emit radiation that is a close approximation to a coherent state: a classical mean field which varies sinusoidally in time at optical frequency ω0, superposed with broad-band noise fields due to the field's quantum uncertainty in its ground state (i.e. vacuum fluctuations). When detected by a standard photodetector, the interference between these vacuum fields and the coherent mean field causes the noise floor commonly referred to as the "shot-noise limit." The vacuum noise also causes fluctuations in the phase of the beam that are independent and uncorrelated with the amplitude fluctuations, and to which photodetectors are insensitive. The amplitude and phase fluctuations of the field can be represented by quadrature amplitudes X ^ A ( δ ) and X ^ ϕ ( δ ) which are the Fourier components of amplitude and phase modulation or fluctuation at a particular modulation frequency δ. These quadrature amplitudes are non-commuting quantum observables which obey the uncertainty principle.
A stabilized laser emits a light beam in a coherent state: a light field with properties very similar to a classical field, but with quantum zero-point fluctuations (vacuum noise) of the field superposed. The nonlinear refractive index of optical fibers can be used to alter the quantum statistics of the light to produce a beam with non-classical properties: a squeezed state. Upon detection, squeezed states exhibit a noise level which is phase-dependent and which can be well below the coherent state level ("shot-noise limit"). The nonlinear refractive index also provides a means for experimental demonstration of the related concept of "quantum non-demolition detection": The measurement of a quantum observable without adding uncertainty to that variable.
The amplitude and phase of all light fields are subject to fluctuations. Much of this irregularity arises from random and uncontrolled changes that occur in any light source and lead to random changes in the light wave's frequency and amplitude. Most of these factors can in principle be eliminated by a careful design of the light source. Even if all of these defects in the source are removed, however, light fields are still subject to fluctuations arising from the laws of quantum mechanics. Even in a highly stabilized laser, the resulting coherent electromagnetic field has an uncertainty in the phase and magnitude of its amplitude. All conventional sources of light fields have at least this noise level, which, in a fully quantum description, arises from vacuum fluctuations. At one time it was believed that this vacuum or coherent-state noise could not be eliminated.
Parametric interactions such as four wave mixing have been predicted to produce states of the radiation field where the quantum fluctuations in one phase quadrature are less than those of a coherent state.1 These “squeezed states” have proved remarkably difficult to generate and detect, not least because of the presence of additional classical noise in many laser sources and parametric devices. We have now demonstrated the reduction of classical fluctuations by means of four wave mixing in an optical fiber under conditions very similar to those needed to demonstrate squeezed state generation. This success reinforces the plausibility of related quantum noise experiments, and has implications for fiber optic communications.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.
Shot NoiseSince the observation of quantum noise is made in the context of photodetector measureinents, it is appropriate to begin by briefly reviewing the concept of noise in general, and the origin of shot noise in photodetection.Noise represents random electromagnetic fields occupying the same spectral region as that occupied by some "signal".With regard to the measurement of optical power, noise causes fluctuations in the measurement, thus placing a lower limit on the smallest amount of power that can be measured.In most situations, the sources of noise are due to the concerted action of a large number of independent agents.In this case the central limit theorem of statistics [35] tells us that the noise is described by a Gaussian distribution with zero mean and a mean square variance r 2 .Time averaged noise power is proportional to this mean square value, or the statistical variance of random fluctuations.For a given observable quantity A, we will use the notation (A) -14 - Chapter 1Photodetectors produce an electric current proportional to the incident radiation, or photon flux, via generation of carriers in a semiconductor.These detectors are characterized by a quantum efficiency which expresses the ratio of the rate of -15 -Chapter 1 spectral density function of a train of randomly occurring electron emission events and the Fourier transform of a single current pulse between the two electrodes of the photodetector [41], and is typically given in terms of the mean square current -16 -Chapter 1 'For two quantum operators, A and B, with a commutator [A, B] = iC, the uncertainty principle states that AA 2 AB 2 > _I(CoI2.From [26].-18 -Chapter 1Even in complete darkness (c) there must be some quantum uncertainty, and so the field strengths are not exactly zero; they too fluctuate within an envelope of uncertainty.From [33].
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).