Intensity noise correlation in a triply resonant optical parametric oscillator

Joseph Teja

Published Jan 1, 1997• 0 citations
OpenAlex

Abstract

Shot NoiseSince the observation of quantum noise is made in the context of photodetector measureinents, it is appropriate to begin by briefly reviewing the concept of noise in general, and the origin of shot noise in photodetection.Noise represents random electromagnetic fields occupying the same spectral region as that occupied by some "signal".With regard to the measurement of optical power, noise causes fluctuations in the measurement, thus placing a lower limit on the smallest amount of power that can be measured.In most situations, the sources of noise are due to the concerted action of a large number of independent agents.In this case the central limit theorem of statistics [35] tells us that the noise is described by a Gaussian distribution with zero mean and a mean square variance r 2 .Time averaged noise power is proportional to this mean square value, or the statistical variance of random fluctuations.For a given observable quantity A, we will use the notation (A) -14 - Chapter 1Photodetectors produce an electric current proportional to the incident radiation, or photon flux, via generation of carriers in a semiconductor.These detectors are characterized by a quantum efficiency which expresses the ratio of the rate of -15 -Chapter 1 spectral density function of a train of randomly occurring electron emission events and the Fourier transform of a single current pulse between the two electrodes of the photodetector [41], and is typically given in terms of the mean square current -16 -Chapter 1 'For two quantum operators, A and B, with a commutator [A, B] = iC, the uncertainty principle states that AA 2 AB 2 > _I(CoI2.From [26].-18 -Chapter 1Even in complete darkness (c) there must be some quantum uncertainty, and so the field strengths are not exactly zero; they too fluctuate within an envelope of uncertainty.From [33].

Related papers

Quantum noise in photonics

CHARLES H. HENRY, Rudolf F. Kazarinov

The basic equations governing noise phenomena are derived from first principles and applied to examples in optical communications. Quantum noise arises from two sources, the momentum fluctuations of electrons at optical frequencies and the uncertainty-related fluctuations of the electromagnetic field. Shot noise results from the beating of the noise sources with the signal field. In high-gain amplifiers, the spontaneous-emission noise dominates shot noise and results in a noise figure of at least 3 dB. It is shown explicitly how, at high power, both the laser field and the laser noise source become classical. The increase in noise in lasers with open cavities is not due to enhanced spontaneous emission as once thought, but to single-pass amplification. The noise fields and spontaneous currents have Gaussian distributions, while nonlasing modes have exponential photon-number distributions. Low-frequency intensity fluctuations arise from the electric current driving the laser and can be sub-Poissonian, in contrast to shot noise, which has a Poissonian distribution. The calculational tools are a wave equation for the field operator and a rate equation for the carrier-number operator, each containing spontaneous current noise sources. The correlation functions of these sources are determined by the fluctuation-dissipation theorem. [S0034-6861(96)00503-X]

Reviews of Modern Physics•Jul 1, 1996•218 citations

Quantum noise figure of fiber OPAs

M.E. Marhic

Introduction In previous chapters we studied wave propagation in fiber OPAs from a classical standpoint, i.e. starting from Maxwell's equations. That approach provides only a partial view of the rich nature of the electromagnetic field, namely its wave nature. However, a complete description of the electromagnetic field requires quantum mechanics. This quantum description of the electromagnetic field (called quantum electrodynamics, or QED) predicts fluctuations in measurable quantities due to the Heisenberg uncertainty principle and sets ultimate limits on the performance of devices such as optical amplifiers. A remarkable result of this theory is that the statistics and thus the noise performance of a system are affected by the quantum statistics of the source and by the physical measurement that is made. Thus a different analysis is needed depending on whether homodyne, heterodyne, or direct detection (where the field simply impinges on a photodiode) is used. Direct detection reveals the particle nature of the electromagnetic field. More specifically, energy arrives in discrete units, called photons, each of which may create an electron–hole pair in a semiconductor photodetector. In particular, the number of photons in an optical pulse can be thought of as a random variable having a mean and a variance. By deriving the mean and variance of the photocurrent that would be present if one performed direct detection of ideal laser light at the input of an optical amplifier and then a similar measurement at its exit, one can quantify the degradation of the signal-to-noise ratio (SNR) caused by the amplifier.

Cambridge University Press eBooks•Nov 15, 2007•0 citations

Squeezed States, Parametric Interactions and Fundamental Noise Sources in Optical Fibers

Robert M. Shelby, M. D. Levenson

Well-stabilized lasers emit radiation that is a close approximation to a coherent state: a classical mean field which varies sinusoidally in time at optical frequency ω0, superposed with broad-band noise fields due to the field's quantum uncertainty in its ground state (i.e. vacuum fluctuations). When detected by a standard photodetector, the interference between these vacuum fields and the coherent mean field causes the noise floor commonly referred to as the "shot-noise limit." The vacuum noise also causes fluctuations in the phase of the beam that are independent and uncorrelated with the amplitude fluctuations, and to which photodetectors are insensitive. The amplitude and phase fluctuations of the field can be represented by quadrature amplitudes X ^ A ( δ ) and X ^ ϕ ( δ ) which are the Fourier components of amplitude and phase modulation or fluctuation at a particular modulation frequency δ. These quadrature amplitudes are non-commuting quantum observables which obey the uncertainty principle.

Nonlinear Guided Waves and Their Applications•Jan 1, 1989•0 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier +2 more

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

Topical Meeting on Quantum-Limited Imaging and Image Processing•Jan 1, 1989•0 citations

Quantum Gaussian noise

Jeffrey H. Shapiro

In semiclassical theory, light is a classical electromagnetic wave and the fundamental source of photodetection noise is the shot effect arising from the discreteness of the electron charge. In quantum theory, light is a quantum-mechanical entity and the fundamental source of photodetection noise comes from measuring the photon-flux operator. The Glauber coherent states are Gaussian quantum states which represent classical electromagnetic radiation. Quantum photodetection of these states yields statistics that are indistinguishable from the corresponding Poisson point-process results of semiclassical photodetection. Optical parametric interactions, however, can be used to produce other Gaussian quantum states, states whose photodetection behavior cannot be characterized semiclassically. A unified analytical framework is presented for Gaussian-state photodetection that includes the full panoply of nonclassical effects that have been produced via parametric interactions.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 16, 2003•19 citations
Shot NoiseSince the observation of quantum noise is made in the context of photodetector measureinents, it is appropriate to begin by briefly reviewing the concept of noise in general, and the origin of shot noise in photodetection.Noise represents random electromagnetic fields occupying the same spectral region as that occupied by some "signal".With regard to the measurement of optical power, noise causes fluctuations in the measurement, thus placing a lower limit on the smallest amount of power that can be measured.In most situations, the sources of noise are due to the concerted action of a large number of independent agents.In this case the central limit theorem of statistics [35] tells us that the noise is described by a Gaussian distribution with zero mean and a mean square variance r 2 .Time averaged noise power is proportional to this mean square value, or the statistical variance of random fluctuations.For a given observable quantity A, we will use the notation (A) -14 - Chapter 1Photodetectors produce an electric current proportional to the incident radiation, or photon flux, via generation of carriers in a semiconductor.These detectors are characterized by a quantum efficiency which expresses the ratio of the rate of -15 -Chapter 1 spectral density function of a train of randomly occurring electron emission events and the Fourier transform of a single current pulse between the two electrodes of the photodetector [41], and is typically given in terms of the mean square current -16 -Chapter 1 'For two quantum operators, A and B, with a commutator [A, B] = iC, the uncertainty principle states that AA 2 AB 2 > _I(CoI2.From [26].-18 -Chapter 1Even in complete darkness (c) there must be some quantum uncertainty, and so the field strengths are not exactly zero; they too fluctuate within an envelope of uncertainty.From [33].
The basic equations governing noise phenomena are derived from first principles and applied to examples in optical communications. Quantum noise arises from two sources, the momentum fluctuations of electrons at optical frequencies and the uncertainty-related fluctuations of the electromagnetic field. Shot noise results from the beating of the noise sources with the signal field. In high-gain amplifiers, the spontaneous-emission noise dominates shot noise and results in a noise figure of at least 3 dB. It is shown explicitly how, at high power, both the laser field and the laser noise source become classical. The increase in noise in lasers with open cavities is not due to enhanced spontaneous emission as once thought, but to single-pass amplification. The noise fields and spontaneous currents have Gaussian distributions, while nonlasing modes have exponential photon-number distributions. Low-frequency intensity fluctuations arise from the electric current driving the laser and can be sub-Poissonian, in contrast to shot noise, which has a Poissonian distribution. The calculational tools are a wave equation for the field operator and a rate equation for the carrier-number operator, each containing spontaneous current noise sources. The correlation functions of these sources are determined by the fluctuation-dissipation theorem. [S0034-6861(96)00503-X]
Introduction In previous chapters we studied wave propagation in fiber OPAs from a classical standpoint, i.e. starting from Maxwell's equations. That approach provides only a partial view of the rich nature of the electromagnetic field, namely its wave nature. However, a complete description of the electromagnetic field requires quantum mechanics. This quantum description of the electromagnetic field (called quantum electrodynamics, or QED) predicts fluctuations in measurable quantities due to the Heisenberg uncertainty principle and sets ultimate limits on the performance of devices such as optical amplifiers. A remarkable result of this theory is that the statistics and thus the noise performance of a system are affected by the quantum statistics of the source and by the physical measurement that is made. Thus a different analysis is needed depending on whether homodyne, heterodyne, or direct detection (where the field simply impinges on a photodiode) is used. Direct detection reveals the particle nature of the electromagnetic field. More specifically, energy arrives in discrete units, called photons, each of which may create an electron–hole pair in a semiconductor photodetector. In particular, the number of photons in an optical pulse can be thought of as a random variable having a mean and a variance. By deriving the mean and variance of the photocurrent that would be present if one performed direct detection of ideal laser light at the input of an optical amplifier and then a similar measurement at its exit, one can quantify the degradation of the signal-to-noise ratio (SNR) caused by the amplifier.
Well-stabilized lasers emit radiation that is a close approximation to a coherent state: a classical mean field which varies sinusoidally in time at optical frequency ω0, superposed with broad-band noise fields due to the field's quantum uncertainty in its ground state (i.e. vacuum fluctuations). When detected by a standard photodetector, the interference between these vacuum fields and the coherent mean field causes the noise floor commonly referred to as the "shot-noise limit." The vacuum noise also causes fluctuations in the phase of the beam that are independent and uncorrelated with the amplitude fluctuations, and to which photodetectors are insensitive. The amplitude and phase fluctuations of the field can be represented by quadrature amplitudes X ^ A ( δ ) and X ^ ϕ ( δ ) which are the Fourier components of amplitude and phase modulation or fluctuation at a particular modulation frequency δ. These quadrature amplitudes are non-commuting quantum observables which obey the uncertainty principle.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).
In semiclassical theory, light is a classical electromagnetic wave and the fundamental source of photodetection noise is the shot effect arising from the discreteness of the electron charge. In quantum theory, light is a quantum-mechanical entity and the fundamental source of photodetection noise comes from measuring the photon-flux operator. The Glauber coherent states are Gaussian quantum states which represent classical electromagnetic radiation. Quantum photodetection of these states yields statistics that are indistinguishable from the corresponding Poisson point-process results of semiclassical photodetection. Optical parametric interactions, however, can be used to produce other Gaussian quantum states, states whose photodetection behavior cannot be characterized semiclassically. A unified analytical framework is presented for Gaussian-state photodetection that includes the full panoply of nonclassical effects that have been produced via parametric interactions.