Applied Optics

Optical weak measurement for the precise thickness determination of an ultra-thin film

Jing-Ru Zhao, Zhenjie Wu, Guiqiang Wang, Chunnan Wang, Bo-Fu Deng, Shuqing Sun

Published Nov 3, 2022• 4 citations
Publisher

Abstract

A total internal reflection system based on the weak value amplification principle is set up for the precise measurement of the thickness of an ultra-thin film. In this system, the film thickness is derived from the change of the double-peak pointer caused by the effective refractive index of the film, which is correlated to its thickness. The sensitivity and resolution of this system reached 2727.21 nm/RIU and 7.2 × 10 − 6 R I U , respectively, determined by using a sodium chloride solution with a refractive index of 1.331911. The growth process of TA/Fe(III) assembled films with thicknesses in the few nanometers range is monitored using the as-set-up system, and the experimental results are consistent with a theoretical calculation based on the Maxwell Garnett effective medium. Additionally, we theoretically calculated the detection limit for the thickness measurement of the film as 22 pm. We clearly provide a potential method for the precise measurement of the thickness of an ultra-thin film.

DOI
10.1364/ao.465029

Related papers

Ultra-sensitive measurement of third-order optical nonlinearity via weak value amplification

Hongjing Li, Yanjia Li, Jingzheng Huang +2 more

An ultrasensitive third-order optical nonlinearity measurement was theoretically proposed and experimentally demonstrated based on an extended Sagnac interferometer using weak value amplification. The predictable nonlinear refractive index coefficient (n2) of a nonlinear optical sample (nematic liquid crystals) accorded with the experimental result, which confirmed the rationality and feasibility of the proposed method. The sensitivity of the proposed method was associated with the resolution of the spectrometer and the postselection angle. By choosing a currently available spectrometer, the minimum Kerr phase of about 7.5 × 10−7 rad could be measured. Moreover, low cost and convenient operation of this method might have potential application in third-order optical nonlinearity measurements.

Applied Physics Letters•Apr 22, 2019•12 citations

Subwavelength thickness characterization of curved dielectric films exploiting spatially structured entangled photons

Enes Ataç, Mehmet Salih Dinleyici

Precise determination of thin dielectric film optical properties is a critical issue for fiber optic sensor technologies. However, conventional methods for the optical characterization of these films not only are generally complex and tedious processes on curved surfaces but also require well-calibrated and overly sophisticated devices. We, on the other hand, propose a novel and practical quantum-based phase diffraction scheme to characterize the thickness of ultra-thin transparent dielectric films coated on an optical fiber beyond the classical diffraction limits in this paper. The approach is implemented by evaluating the effect of thickness variations on the highly visible two-photon diffraction pattern’s zero crossings and amplitudes. The mathematical model and numerical simulations contribute to a better understanding of how the spatially structured entangled photons improve thickness precision with the help of intensity correlations and a confocal aperture. To prove the impact of the proposed system, it is compared with the classical phase diffraction method in the literature via simulations. According to the results, the thickness of the transparent dielectric films can be accurately estimated below one-twentieth of the wavelength of interest.

Journal of the Optical Society of America B•Jun 20, 2023•8 citations

Precision metrology with weak measurements using spin splitting of light

Xiaodong Qiu, Linguo Xie, Jinglei Du +3 more

Since its first introduction over twenty years ago, weak measurements have gradually became an useful metrology tool in the laboratory. Due to its desirable amplification effect, a small physical variable can be detected with weak measurements. Spin splitting of light, which stems from the interaction between the spin and orbital angular momentum in optical reflection or refraction at the interface of mediums, is always a weak effect. However, the spin splitting of light can be detected easily with weak measurements. Remarkably, the spin splitting of light is sensitive to the physical parameter variations of system. Using the spin splitting as a probe, the physical parameter can be accurately estimated with weak measurements. Here, we review some of our works on precision metrology with weak measurements using the spin splitting of light as a probe, such as estimation of the magneto-optical constant of a magnetic film, determination of the focused beam waist, and measurement of the polarization state of light.

IEEE International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO)•Jul 1, 2016•1 citation

Quasiparticle generation efficiency in superconducting thin films

Tejas Guruswamy, D. J. Goldie, S. Withington

Thin-film superconductors with thickness ∼30–500 nm are used as non-equilibrium quantum detectors for photons, phonons or more exotic particles. One of the most basic questions in determining their limiting sensitivity is the efficiency with which the quanta of interest couple to the detected quasiparticles. As low temperature superconducting resonators, thin films are attractive candidates for producing quantum-sensitive arrayable sensors and the readout uses an additional microwave probe. We have calculated the quasiparticle generation efficiency η s for low energy photons in a representative, clean thin-film superconductor (Al) operating well below its superconducting transition temperature as a function of film thickness, within the framework of the coupled kinetic equations described by Chang and Scalapino (1978 J. Low Temp. Phys. 31 1–32). We have also included the effect of a lower frequency probe. We show that phonon loss from the thin film reduces η s by as much as 40% compared to earlier models that considered relatively thick films or infinite volumes. We also show that the presence of the probe and signal enhances the generation efficiency slightly. We conclude that the ultimate limiting noise equivalent power of this class of detector is determined by the thin-film geometry.

arXiv:1401.1937•Superconductor Science and Technology•Mar 11, 2014•63 citations

Linear pulse propagation in an absorbing medium: Effect of film thickness

J. A. Gaspar, P. Halevi

We compute the peak velocity of a broad Gaussian pulse propagating in an absorbing thin film modeled with a one-oscillator dielectric function. The exact numerical calculation is done for a GaP:N film in the frequency region of the bound A exciton. For absorption lengths greater than the film thickness, the pulse velocity essentially coincides with the group velocity, and with the experimental results of S. Chu and S. Wong [Phys. Rev. Lett. 48, 738 (1982)]. However, outside the region of strong absorption the pulse velocity depends sensitively upon the thickness of the slab. Our results give a better account of the Chu and Wong experiment than the calculation based on the group velocity. For film thickness with smaller than one absorption length the pulse velocity disagrees with the group velocity even in the strong absorption region, as a consequence of Fabry-P\'erot reflections of the pulse inside the film.

Physical review. B, Condensed matter•Apr 15, 1994•5 citations

Sub-nanometer optical path difference measurement using biased weak measurement with real weak values

Huang Jing-Hui, Jingzheng Huang, Hongliang Cui +5 more

We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.

•Mar 26, 2026•0 citations
A total internal reflection system based on the weak value amplification principle is set up for the precise measurement of the thickness of an ultra-thin film. In this system, the film thickness is derived from the change of the double-peak pointer caused by the effective refractive index of the film, which is correlated to its thickness. The sensitivity and resolution of this system reached 2727.21 nm/RIU and 7.2 × 10 − 6 R I U , respectively, determined by using a sodium chloride solution with a refractive index of 1.331911. The growth process of TA/Fe(III) assembled films with thicknesses in the few nanometers range is monitored using the as-set-up system, and the experimental results are consistent with a theoretical calculation based on the Maxwell Garnett effective medium. Additionally, we theoretically calculated the detection limit for the thickness measurement of the film as 22 pm. We clearly provide a potential method for the precise measurement of the thickness of an ultra-thin film.
An ultrasensitive third-order optical nonlinearity measurement was theoretically proposed and experimentally demonstrated based on an extended Sagnac interferometer using weak value amplification. The predictable nonlinear refractive index coefficient (n2) of a nonlinear optical sample (nematic liquid crystals) accorded with the experimental result, which confirmed the rationality and feasibility of the proposed method. The sensitivity of the proposed method was associated with the resolution of the spectrometer and the postselection angle. By choosing a currently available spectrometer, the minimum Kerr phase of about 7.5 × 10−7 rad could be measured. Moreover, low cost and convenient operation of this method might have potential application in third-order optical nonlinearity measurements.
Precise determination of thin dielectric film optical properties is a critical issue for fiber optic sensor technologies. However, conventional methods for the optical characterization of these films not only are generally complex and tedious processes on curved surfaces but also require well-calibrated and overly sophisticated devices. We, on the other hand, propose a novel and practical quantum-based phase diffraction scheme to characterize the thickness of ultra-thin transparent dielectric films coated on an optical fiber beyond the classical diffraction limits in this paper. The approach is implemented by evaluating the effect of thickness variations on the highly visible two-photon diffraction pattern’s zero crossings and amplitudes. The mathematical model and numerical simulations contribute to a better understanding of how the spatially structured entangled photons improve thickness precision with the help of intensity correlations and a confocal aperture. To prove the impact of the proposed system, it is compared with the classical phase diffraction method in the literature via simulations. According to the results, the thickness of the transparent dielectric films can be accurately estimated below one-twentieth of the wavelength of interest.
Since its first introduction over twenty years ago, weak measurements have gradually became an useful metrology tool in the laboratory. Due to its desirable amplification effect, a small physical variable can be detected with weak measurements. Spin splitting of light, which stems from the interaction between the spin and orbital angular momentum in optical reflection or refraction at the interface of mediums, is always a weak effect. However, the spin splitting of light can be detected easily with weak measurements. Remarkably, the spin splitting of light is sensitive to the physical parameter variations of system. Using the spin splitting as a probe, the physical parameter can be accurately estimated with weak measurements. Here, we review some of our works on precision metrology with weak measurements using the spin splitting of light as a probe, such as estimation of the magneto-optical constant of a magnetic film, determination of the focused beam waist, and measurement of the polarization state of light.
Thin-film superconductors with thickness ∼30–500 nm are used as non-equilibrium quantum detectors for photons, phonons or more exotic particles. One of the most basic questions in determining their limiting sensitivity is the efficiency with which the quanta of interest couple to the detected quasiparticles. As low temperature superconducting resonators, thin films are attractive candidates for producing quantum-sensitive arrayable sensors and the readout uses an additional microwave probe. We have calculated the quasiparticle generation efficiency η s for low energy photons in a representative, clean thin-film superconductor (Al) operating well below its superconducting transition temperature as a function of film thickness, within the framework of the coupled kinetic equations described by Chang and Scalapino (1978 J. Low Temp. Phys. 31 1–32). We have also included the effect of a lower frequency probe. We show that phonon loss from the thin film reduces η s by as much as 40% compared to earlier models that considered relatively thick films or infinite volumes. We also show that the presence of the probe and signal enhances the generation efficiency slightly. We conclude that the ultimate limiting noise equivalent power of this class of detector is determined by the thin-film geometry.
We compute the peak velocity of a broad Gaussian pulse propagating in an absorbing thin film modeled with a one-oscillator dielectric function. The exact numerical calculation is done for a GaP:N film in the frequency region of the bound A exciton. For absorption lengths greater than the film thickness, the pulse velocity essentially coincides with the group velocity, and with the experimental results of S. Chu and S. Wong [Phys. Rev. Lett. 48, 738 (1982)]. However, outside the region of strong absorption the pulse velocity depends sensitively upon the thickness of the slab. Our results give a better account of the Chu and Wong experiment than the calculation based on the group velocity. For film thickness with smaller than one absorption length the pulse velocity disagrees with the group velocity even in the strong absorption region, as a consequence of Fabry-P\'erot reflections of the pulse inside the film.
We experimentally demonstrate an ultra-sensitive technique for measuring sub-nanometer optical path differences (OPDs) using the biased weak measurement (BWM) protocol. By employing real weak values with a classical coherent light source and introducing a bias phase procedure, this method directly amplifies small OPDs in interferometry, achieving significantly enhanced amplification compared to conventional measurement (CM) and standard weak measurement (SWM). In a proof-of-principle experiment of sub-nanometer OPD measurement, BWM achieves nearly 4× signal improvement within the linear response range relative to SWM, and an 85× improvement over CM. The signal-to-noise ratio of BWM and SWM exhibits an order-of-magnitude enhancement on average compared to CM. Furthermore, we experimentally determine a minimum OPD resolution of 3.1×10-4nm, corresponding to a time delay of 1 ×10-3attoseconds and a phase shift of 3.0× 10-6rad. These results highlight the potential of weak measurement protocols for high-precision longitudinal phase estimation using narrow-band sources and common optical components.