Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Ultra-sensitive measurement of third-order optical nonlinearity via weak value amplification

Hongjing Li, Yanjia Li, Jingzheng Huang, Miaomiao Liu, Guihua Zeng

Published Apr 22, 2019• 12 citations
Publisher

Abstract

An ultrasensitive third-order optical nonlinearity measurement was theoretically proposed and experimentally demonstrated based on an extended Sagnac interferometer using weak value amplification. The predictable nonlinear refractive index coefficient (n2) of a nonlinear optical sample (nematic liquid crystals) accorded with the experimental result, which confirmed the rationality and feasibility of the proposed method. The sensitivity of the proposed method was associated with the resolution of the spectrometer and the postselection angle. By choosing a currently available spectrometer, the minimum Kerr phase of about 7.5 × 10−7 rad could be measured. Moreover, low cost and convenient operation of this method might have potential application in third-order optical nonlinearity measurements.

DOI
10.1063/1.5089605

Related papers

Accurate and precise optical phase sensor based on a nonlinear quantum Sagnac interferometer

Romain Dalidet, Laurent Labonté, Grégory Sauder +2 more

Optical phase measurements play a key role in the detection of macroscopic parameters such as position, velocity, and displacement. They also permit to qualify the microscopic properties of photonic waveguides such as polarization mode dispersion, refractive index difference, and chromatic dispersion. In the quest for ever-better measurement performance and relevance, we report a quantum nonlinear interferometer based on a Sagnac configuration allowing precise, accurate, self-stabilized, and reproductible optical phase measurement. The potential of this system is demonstrated through the measurement of second-order dispersion, namely, chromatic dispersion of a commercial dispersion-shifted fiber at telecommunication wavelength. We demonstrate a precision of 0.007 % , surpassing state-of-the-art measurements by more than one order of magnitude. Additionally, the accuracy of the second-order dispersion value is determined through the measurement of the third-order dispersion, showing a quadratic error as low as 5%. Our system promises the development of photonic-based sensors enabling the measurements of optical-material properties in a user-friendly manner.

arXiv:2412.13744•Physical Review Research•Jul 14, 2025•3 citations

Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification

P. Ben Dixon, David J. Starling, Andrew N. Jordan +1 more

We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.

arXiv:0906.4828•Physical Review Letters•Apr 27, 2009•773 citations

High-precision temperature measurement based on weak measurement using nematic liquid crystals

Hongjing Li, Jingzheng Huang, Yu Yang +3 more

High-precision temperature measurements could guarantee temperature difference control accuracy in research and industrial production. To flexibly achieve high precision and large operating temperature range is a crucial problem for temperature measurements. Here, we demonstrate a method for a high-precision temperature measurement based on a weak measurement done using nematic liquid crystals (NLCs). By performing an analysis in the frequency domain, the temperature variation of NLCs is measured using a Sagnac interferometer with appropriate preselection and postselection. In order to obtain a large operating temperature range, there is a relatively large time delay that resulted from NLCs, and an operational principle is deduced explicitly by Jones matrices. In the proposed method, the precision of 3 × 10−6 °C could be achieved by a currently available spectrometer and the operating temperature range can be modulated by the thickness of NLCs. Moreover, the temperature sensitivity of 13.5 nm/°C could be realized for NLCs with 100 μm thickness, which exhibits at least three orders of magnitude larger than the value for other frequency domain analyses.

Applied Physics Letters•Jun 4, 2018•57 citations

Optical weak measurement for the precise thickness determination of an ultra-thin film

Jing-Ru Zhao, Zhenjie Wu, Guiqiang Wang +3 more

A total internal reflection system based on the weak value amplification principle is set up for the precise measurement of the thickness of an ultra-thin film. In this system, the film thickness is derived from the change of the double-peak pointer caused by the effective refractive index of the film, which is correlated to its thickness. The sensitivity and resolution of this system reached 2727.21 nm/RIU and 7.2 × 10 − 6 R I U , respectively, determined by using a sodium chloride solution with a refractive index of 1.331911. The growth process of TA/Fe(III) assembled films with thicknesses in the few nanometers range is monitored using the as-set-up system, and the experimental results are consistent with a theoretical calculation based on the Maxwell Garnett effective medium. Additionally, we theoretically calculated the detection limit for the thickness measurement of the film as 22 pm. We clearly provide a potential method for the precise measurement of the thickness of an ultra-thin film.

Applied Optics•Nov 3, 2022•4 citations

Phase-sensitive amplification of optical signal by an SOA in a nonlinear Sagnac interferometer

Yongzhang Leng, Christopher J. K. Richardson, J. Goldhar

Phase-sensitive amplification of picosecond optical pulses was demonstrated using an SOA as the nonlinear medium inside a Sagnac interferometer with a weak control signal. Numerical simulations using a semiconductor amplifier model are consistent with experiments.

Conference on Lasers and Electro-Optics•May 1, 2008•1 citation

Toward quantum-noise-limited interferometric measurements of optical nonlinearity in vacuum

Ali Aras, Adrien E. Kraych, Xavier Sarazin +3 more

Quantum Electrodynamics predicts that the vacuum must behave as a nonlinear optical medium: the vacuum optical index should increase when it is stressed by intense electromagnetic fields. The DeLLight (Deflection of Light by Light) project aims to measure it by using intense and ultra-short laser pulses. The experiment uses a Sagnac interferometer to amplify the tiny deflection signal of a low-intensity probe pulse crossing the vacuum refractive-index gradient produced by an external high-intensity pump pulse. The measurement of the amplified signal by a CCD camera requires a high spatial resolution, which is limited by the ultimate quantum noise of the CCD. However, interferometric phase noise induced by the mechanical vibrations of the interferometer is also amplified and degrades spatial resolution. To overcome this, we propose a new method named High-Frequency Phase Noise Suppression (HFPNS), based on the addition of a delayed replica (5 ns) of the probe pulse. The delayed pulse, which is not affected by the pump but is subject to the same vibration noise, enables offline subtraction of correlated phase noise. In this work, we present an experimental proof-of-concept on a prototype interferometer operating with a limited amplification factor ($\mathcal{A}\simeq25$), about 10 times smaller than the required value of the final experiment. We have succeeded in reducing phase noise by a factor of 40, resulting in a residual noise level 2.3 times higher than the expected quantum noise. The residual noise is linked to delay-line instabilities and incident beam pointing fluctuations present during these tests. This result validates HFPNS as a robust method for future quantum-noise-limited interferometric measurements of vacuum optical nonlinearity, though additional stabilization and higher interferometric amplification are still needed.

physics.opticsCross-listedarXiv:2602.10896•Physical Review A•Feb 12, 2026•0 citations
An ultrasensitive third-order optical nonlinearity measurement was theoretically proposed and experimentally demonstrated based on an extended Sagnac interferometer using weak value amplification. The predictable nonlinear refractive index coefficient (n2) of a nonlinear optical sample (nematic liquid crystals) accorded with the experimental result, which confirmed the rationality and feasibility of the proposed method. The sensitivity of the proposed method was associated with the resolution of the spectrometer and the postselection angle. By choosing a currently available spectrometer, the minimum Kerr phase of about 7.5 × 10−7 rad could be measured. Moreover, low cost and convenient operation of this method might have potential application in third-order optical nonlinearity measurements.
Optical phase measurements play a key role in the detection of macroscopic parameters such as position, velocity, and displacement. They also permit to qualify the microscopic properties of photonic waveguides such as polarization mode dispersion, refractive index difference, and chromatic dispersion. In the quest for ever-better measurement performance and relevance, we report a quantum nonlinear interferometer based on a Sagnac configuration allowing precise, accurate, self-stabilized, and reproductible optical phase measurement. The potential of this system is demonstrated through the measurement of second-order dispersion, namely, chromatic dispersion of a commercial dispersion-shifted fiber at telecommunication wavelength. We demonstrate a precision of 0.007 % , surpassing state-of-the-art measurements by more than one order of magnitude. Additionally, the accuracy of the second-order dispersion value is determined through the measurement of the third-order dispersion, showing a quadratic error as low as 5%. Our system promises the development of photonic-based sensors enabling the measurements of optical-material properties in a user-friendly manner.
We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.
High-precision temperature measurements could guarantee temperature difference control accuracy in research and industrial production. To flexibly achieve high precision and large operating temperature range is a crucial problem for temperature measurements. Here, we demonstrate a method for a high-precision temperature measurement based on a weak measurement done using nematic liquid crystals (NLCs). By performing an analysis in the frequency domain, the temperature variation of NLCs is measured using a Sagnac interferometer with appropriate preselection and postselection. In order to obtain a large operating temperature range, there is a relatively large time delay that resulted from NLCs, and an operational principle is deduced explicitly by Jones matrices. In the proposed method, the precision of 3 × 10−6 °C could be achieved by a currently available spectrometer and the operating temperature range can be modulated by the thickness of NLCs. Moreover, the temperature sensitivity of 13.5 nm/°C could be realized for NLCs with 100 μm thickness, which exhibits at least three orders of magnitude larger than the value for other frequency domain analyses.
A total internal reflection system based on the weak value amplification principle is set up for the precise measurement of the thickness of an ultra-thin film. In this system, the film thickness is derived from the change of the double-peak pointer caused by the effective refractive index of the film, which is correlated to its thickness. The sensitivity and resolution of this system reached 2727.21 nm/RIU and 7.2 × 10 − 6 R I U , respectively, determined by using a sodium chloride solution with a refractive index of 1.331911. The growth process of TA/Fe(III) assembled films with thicknesses in the few nanometers range is monitored using the as-set-up system, and the experimental results are consistent with a theoretical calculation based on the Maxwell Garnett effective medium. Additionally, we theoretically calculated the detection limit for the thickness measurement of the film as 22 pm. We clearly provide a potential method for the precise measurement of the thickness of an ultra-thin film.
Quantum Electrodynamics predicts that the vacuum must behave as a nonlinear optical medium: the vacuum optical index should increase when it is stressed by intense electromagnetic fields. The DeLLight (Deflection of Light by Light) project aims to measure it by using intense and ultra-short laser pulses. The experiment uses a Sagnac interferometer to amplify the tiny deflection signal of a low-intensity probe pulse crossing the vacuum refractive-index gradient produced by an external high-intensity pump pulse. The measurement of the amplified signal by a CCD camera requires a high spatial resolution, which is limited by the ultimate quantum noise of the CCD. However, interferometric phase noise induced by the mechanical vibrations of the interferometer is also amplified and degrades spatial resolution. To overcome this, we propose a new method named High-Frequency Phase Noise Suppression (HFPNS), based on the addition of a delayed replica (5 ns) of the probe pulse. The delayed pulse, which is not affected by the pump but is subject to the same vibration noise, enables offline subtraction of correlated phase noise. In this work, we present an experimental proof-of-concept on a prototype interferometer operating with a limited amplification factor (A≃25\mathcal{A}\simeq25A≃25), about 10 times smaller than the required value of the final experiment. We have succeeded in reducing phase noise by a factor of 40, resulting in a residual noise level 2.3 times higher than the expected quantum noise. The residual noise is linked to delay-line instabilities and incident beam pointing fluctuations present during these tests. This result validates HFPNS as a robust method for future quantum-noise-limited interferometric measurements of vacuum optical nonlinearity, though additional stabilization and higher interferometric amplification are still needed.