Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical Lattice Clocks: paving the road towards ultimate stabilities

Rodolphe Le Targat, Jean-Luc Robyr, Chunyan Shi, Sławomir Bilicki, Jérôme Lodewyck

Published Apr 13, 2015• 0 citations
OpenAlex

Related papers

Optical lattice clocks near the QPN limit: a tenfold improvement in optical clock stability

Travis Nicholson

Bulletin of the American Physical Society•Jun 7, 2013•0 citations

An optical lattice clock with accuracy and stability at the 10−18 level

Benjamin Bloom, Travis Nicholson, Jason Williams +6 more

arXiv:1309.1137•Nature•Jan 22, 2014•1,108 citations

Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems

Qi Gao, Min Zhou, Chengyin Han +12 more

Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.

Scientific Reports•May 16, 2018•44 citations

Optical Lattice Clocks and Applications

S. Bize

•Dec 4, 2013•0 citations

Ever-evolving optical lattice clocks

Noriaki Horiuchi

Nature Photonics•Dec 20, 2021•1 citation

Prospects for frequency stabilization using collective effects of strontium atoms in an optical cavity

Bjarke T. R. Christensen, Martin R. Henriksen, Philip G. Westergaard +2 more

The stability of current state-of-the-art optical atomic clocks [1]-[5] is mostly limited by the frequency noise of the interrogation oscillator through the Dick effect. To achieve the heralded ultimate stability, future optical frequency standards will need to produce light sources with frequency stability at the 10−17fractional level or below at one second of integration time. Recently, a new frontier in cavity stabilized laser sources has pushed the fractional instability to the lower 10−16level at one second of integration time [6]-[8]. However, this instability is limited by thermal noise in the reference cavity elements and may be difficult to reduce further. These state-of-the-art reference cavities are technically challenging to construct and their stability is still at least an order of magnitude too large for lattice clocks to achieve their ultimate performance.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations
Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
The stability of current state-of-the-art optical atomic clocks [1]-[5] is mostly limited by the frequency noise of the interrogation oscillator through the Dick effect. To achieve the heralded ultimate stability, future optical frequency standards will need to produce light sources with frequency stability at the 10−17fractional level or below at one second of integration time. Recently, a new frontier in cavity stabilized laser sources has pushed the fractional instability to the lower 10−16level at one second of integration time [6]-[8]. However, this instability is limited by thermal noise in the reference cavity elements and may be difficult to reduce further. These state-of-the-art reference cavities are technically challenging to construct and their stability is still at least an order of magnitude too large for lattice clocks to achieve their ultimate performance.