Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Scientific Reports

Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems

Qi Gao, Min Zhou, Chengyin Han, Shangyan Li, Shuang Zhang, Yuan Yao, Bo Li, Hao Qiao, Di Ai, Ge Lou, Mengya Zhang, Yanyi Jiang, Zhiyi Bi, Long-Sheng Ma, Xinye Xu

Published May 16, 2018• 44 citations
Publisher

Abstract

Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.

DOI
10.1038/s41598-018-26365-w

Related papers

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•206 citations

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•0 citations

Study of optical clocks based on ultracold 171Yb atoms*

Di Ai, Hao Qiao, Shuang Zhang +8 more

The optical atomic clocks have the potential to transform global timekeeping, relying on the state-of-the-art accuracy and stability, and greatly improve the measurement precision for a wide range of scientific and technological applications. Herein we report on the development of the optical clock based on 171Yb atoms confined in an optical lattice. A minimum width of 1.92-Hz Rabi spectra has been obtained with a new 578-nm clock interrogation laser. The in-loop fractional instability of the 171Yb clock reaches 9.1 × 10−18 after an averaging over a time of 2.0 × 104 s. By synchronous comparison between two clocks, we demonstrate that our 171Yb optical lattice clock achieves a fractional instability of 4.60 × 10 − 16 / τ .

Chinese Physics B•Jun 29, 2020•16 citations

Absolute frequency measurement of 171Yb in a one-dimensional optical lattice

Takuya Kohno, Masami Yasuda, Kazumoto Hosaka +4 more

We demonstrate the spectroscopy of171Yb atoms confined in a one-dimensional (1D) optical lattice and the absolute frequency measurement of the clock transition. The absolute frequency of the1S0(F = 1/2) -3P0(F = 1/2) clock transition in171Yb is determined to be 518 295 836 590 864(28) Hz with respect to the SI second.

Conference on Precision Electromagnetic Measurements•Jun 1, 2010•0 citations

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•28 citations

Development of an Yb optical lattice clock using a fermionic isotope

Masami Yasuda, Takuya Kohno, Kazumoto Hosaka +5 more

We have developed a one-dimensional optical lattice clock with ultracold 171Yb atoms. The absolute frequency of the 1S0(F = 1/2) - 3P0(F = 1/2) clock transition in 171Yb is determined to be 518 295 836 590 864(28) Hz with respect to the SI second. Details of the experimental setups and atom trapping results are also described.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 20, 2009•1 citation
Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
The optical atomic clocks have the potential to transform global timekeeping, relying on the state-of-the-art accuracy and stability, and greatly improve the measurement precision for a wide range of scientific and technological applications. Herein we report on the development of the optical clock based on 171Yb atoms confined in an optical lattice. A minimum width of 1.92-Hz Rabi spectra has been obtained with a new 578-nm clock interrogation laser. The in-loop fractional instability of the 171Yb clock reaches 9.1 × 10−18 after an averaging over a time of 2.0 × 104 s. By synchronous comparison between two clocks, we demonstrate that our 171Yb optical lattice clock achieves a fractional instability of 4.60 × 10 − 16 / τ .
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.