Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Hermitian operator of a Mach–Zehnder interferometer combined with parity detection and its applications

Shuai Wang, Jiandong Zhang

Published Sep 15, 2022• 5 citations
Publisher
DOI
10.1016/j.optcom.2022.128987

Related papers

Enhanced performance of an all-optical parity checker using a single Mach-Zehnder interferometer

Yow, Chai Chai, Williams +2 more

Conference on Lasers and Electro-Optics•Jan 1, 2003•0 citations

New Derivation and Applications of the Parity Operator in Quantum Optics

展德会 ZHAN De-hui, 范洪义 FAN Hong-yi

Acta Sinica Quantum Optica•Jan 1, 2018•0 citations

Parity detection and entanglement with a Mach-Zehnder interferometer

Géraldine Haack, Heidi Förster, Μ. Büttiker

A parity meter projects the state of two qubits onto two subspaces with different parities, the states in each parity class being indistinguishable. It has application in quantum information for its entanglement properties. In our work we consider the electronic Mach-Zehnder interferometer (MZI) coupled capacitively to two double quantum dots (DQDs), one on each arm of the MZI. These charge qubits couple linearly to the charge in the arms of the MZI. A key advantage of an MZI is that the qubits are well separated in distance so that mutual interaction between them is avoided. Assuming equal coupling between both DQDs and the arms and the same bias for each DQD, this setup usually detects three different currents, one for the odd states and two for each even state. Controlling the magnetic flux of the MZI, we can operate the MZI as a parity meter: only two currents are measured at the output, one for each parity class. In this configuration, the MZI acts as an ideal detector, its Heisenberg efficiency being maximal. Initially unentangled DQDs become entangled through the parity measurement process with probability one and for a class of initial states our parity meter deterministically generates Bell states.

arXiv:1005.3976•Physical Review B•Oct 1, 2010•36 citations

Quantum sub-phase sensitivity of a Mach–Zehnder interferometer with the superposition of Schrödinger’s cat-like state with vacuum state as an input under product detection scheme

Gaurav K. Shukla, Dhiraj Yadav, Priyanka Sharma +2 more

We study the phase sensitivity of a Mach–Zehnder interferometer (MZI) with product detection (PD) scheme by using the superposition of Schrödinger’s cat-like state with the vacuum state (SCVS) and the coherent state as the inputs. We compare the results derived from PD with the parity detection scheme’s results. We found that PD performs better than parity detection and approaches the single parameter quantum Cramér-Rao bound in some cases. Therefore, we expect that SCVS may play as an alternative quantum resource with PD for the improvement in the phase sensitivity of an MZI having potential application in quantum metrology and quantum sensing.

Physics Open•Dec 9, 2023•12 citations

Wave theory of the Mach-Zehnder interferometer

H. K. Zienkiewicz

•Jan 1, 1959•2 citations

Two-mode quantum interferometry with a single-mode Fock state and parity detection

Shuai Wang, Yao‐Ting Wang, Liang-Jun Zhai +1 more

We derive a general expression of the expectation value of the parity operator in a Mach–Zehnder interferometer with a Fock state in one input port and an arbitrary state in the other input. We obtain the quantum Crámer–Rao bound via the error propagation method from parity detection for the phase shift around zero. In addition, for an arbitrary state with the same mean photon number, our results show that the same phase resolution and the same phase uncertainty can be obtained for the phase shift around zero. That is to say, when a Mach–Zehnder interferometer is powered by a Fock state into one input port, all quantum states with same mean photon number at the other input may have the same performance in the phase estimation via parity detection. As some specific applications, we consider the arbitrary state being a Fock state, a coherent state, and a squeezed-vacuum state.

Journal of the Optical Society of America B•Apr 9, 2018•7 citations
A parity meter projects the state of two qubits onto two subspaces with different parities, the states in each parity class being indistinguishable. It has application in quantum information for its entanglement properties. In our work we consider the electronic Mach-Zehnder interferometer (MZI) coupled capacitively to two double quantum dots (DQDs), one on each arm of the MZI. These charge qubits couple linearly to the charge in the arms of the MZI. A key advantage of an MZI is that the qubits are well separated in distance so that mutual interaction between them is avoided. Assuming equal coupling between both DQDs and the arms and the same bias for each DQD, this setup usually detects three different currents, one for the odd states and two for each even state. Controlling the magnetic flux of the MZI, we can operate the MZI as a parity meter: only two currents are measured at the output, one for each parity class. In this configuration, the MZI acts as an ideal detector, its Heisenberg efficiency being maximal. Initially unentangled DQDs become entangled through the parity measurement process with probability one and for a class of initial states our parity meter deterministically generates Bell states.
We study the phase sensitivity of a Mach–Zehnder interferometer (MZI) with product detection (PD) scheme by using the superposition of Schrödinger’s cat-like state with the vacuum state (SCVS) and the coherent state as the inputs. We compare the results derived from PD with the parity detection scheme’s results. We found that PD performs better than parity detection and approaches the single parameter quantum Cramér-Rao bound in some cases. Therefore, we expect that SCVS may play as an alternative quantum resource with PD for the improvement in the phase sensitivity of an MZI having potential application in quantum metrology and quantum sensing.
We derive a general expression of the expectation value of the parity operator in a Mach–Zehnder interferometer with a Fock state in one input port and an arbitrary state in the other input. We obtain the quantum Crámer–Rao bound via the error propagation method from parity detection for the phase shift around zero. In addition, for an arbitrary state with the same mean photon number, our results show that the same phase resolution and the same phase uncertainty can be obtained for the phase shift around zero. That is to say, when a Mach–Zehnder interferometer is powered by a Fock state into one input port, all quantum states with same mean photon number at the other input may have the same performance in the phase estimation via parity detection. As some specific applications, we consider the arbitrary state being a Fock state, a coherent state, and a squeezed-vacuum state.