Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Two-mode quantum interferometry with a single-mode Fock state and parity detection

Shuai Wang, Yao‐Ting Wang, Liang-Jun Zhai, Lijian Zhang

Published Apr 9, 2018• 7 citations
Publisher

Abstract

We derive a general expression of the expectation value of the parity operator in a Mach–Zehnder interferometer with a Fock state in one input port and an arbitrary state in the other input. We obtain the quantum Crámer–Rao bound via the error propagation method from parity detection for the phase shift around zero. In addition, for an arbitrary state with the same mean photon number, our results show that the same phase resolution and the same phase uncertainty can be obtained for the phase shift around zero. That is to say, when a Mach–Zehnder interferometer is powered by a Fock state into one input port, all quantum states with same mean photon number at the other input may have the same performance in the phase estimation via parity detection. As some specific applications, we consider the arbitrary state being a Fock state, a coherent state, and a squeezed-vacuum state.

DOI
10.1364/josab.35.001046

Related papers

Optical enhanced interferometry with two-mode squeezed twin-Fock states and parity detection*

Li-Li Hou, Shuai Wang, Xuefen Xu

We theoretically investigate the quantum enhanced metrology using two-mode squeezed twin-Fock states and parity detection. Our results indicate that, for a given initial squeezing parameter, compared with the two-mode squeezed vacuum state, both phase sensitivity and resolution can be enhanced when the two-mode squeezed twin-Fock state is considered as an input state of a Mach–Zehnder interferometer. Within a constraint on the total photon number, although the two-mode squeezed vacuum state gives the better phase sensitivity when the phase shift φ to be estimated approaches to zero, the phase sensitivity offered by these non-Gaussian entangled Gaussian states is relatively stable with respect to the phase shift itself. When the phase shift slightly deviates from φ = 0, the phase sensitivity can be still enhanced by the two-mode squeezed twin-Fock state over a broad range of the total mean photon number where the phase uncertainty is still below the quantum standard noise limit. Finally, we numerically prove that the quantum Cramér–Rao bound can be approached with the parity detection.

Chinese Physics B•Jan 7, 2020•10 citations

Phase Detection at the Quantum Limit with Multiphoton Mach-Zehnder Interferometry

Luca Pezzè, Augusto Smerzi, G. Khoury +2 more

We study a Mach-Zehnder interferometer fed by a coherent state in one input port and vacuum in the other. We explore a Bayesian phase estimation strategy to demonstrate that it is possible to achieve the standard quantum limit independently from the true value of the phase shift and specific assumptions on the noise of the interferometer. We have been able to implement the protocol by using parallel operation of two photon-number-resolving detectors and multiphoton coincidence logic electronics at the output ports of a weakly illuminated Mach-Zehnder interferometer. This protocol is unbiased, saturates the Cramer-Rao phase uncertainty bound, and, therefore, is an optimal phase estimation strategy.

arXiv:quant-ph/0701158•Physical Review Letters•Nov 27, 2007•136 citations

Quantum optical interferometry via general photon-subtracted two-mode squeezed states*

Li-Li Hou, Jianzhong Xue, Yongxing Sui +1 more

We investigate the sensitivity of phase estimation in a Mach–Zehnder interferometer with photon-subtracted two-mode squeezed vacuum states. Our results show that, for given initial squeezing parameter, both symmetric and asymmetric photon subtractions can further improve the quantum Cramér–Rao bound (i.e., the ultimate phase sensitivity), especially for single-mode photon subtraction. On the other hand, the quantum Cramér–Rao bound can be reached by parity detection for symmetric photon-subtracted two-mode squeezed vacuum states at particular values of the phase shift, but it is not valid for asymmetric photon-subtracted two-mode squeezed vacuum states. In addition, compared with the two-mode squeezed vacuum state, the phase sensitivity via parity detection with asymmetric photon-subtracted two-mode squeezed vacuum states will be getting worse. Thus, parity detection may not always be the optimal detection scheme for nonclassical states of light when they are considered as the interferometer states.

Chinese Physics B•Aug 6, 2019•7 citations

Mach-Zehnder Interferometry at the Heisenberg Limit with Coherent and Squeezed-Vacuum Light

Luca Pezzè, Augusto Smerzi

We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where ${N}_{T}$ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter $r$ and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.

arXiv:0705.4631•Physical Review Letters•Feb 19, 2008•370 citations

Quantum optical interferometry via the photon-added two-mode squeezed vacuum states

Yi Ouyang, Shuai Wang, Lijian Zhang

We investigate the sensitivity and resolution of phase estimation in a Mach–Zehnder interferometer with photon-added two-mode squeezed vacuum states (PA-TMSVS) with a photon-number parity measurement scheme. Our results indicate that, when the phase to be estimated is small, the PA-TMSVS offers an improved phase resolution over both the two-mode squeezed vacuum and the photon-subtracted two-mode squeezed vacuum for a given initial squeezing level. In addition, we study the behavior of the quantum Fisher information of the PA-TMSVS, and show that the optimum phase uncertainty predicted by the corresponding Cramer–Rao bound can be achieved with a parity measurement.

Journal of the Optical Society of America B•Jun 3, 2016•72 citations

Quantum interferometry via a coherent state mixed with a squeezed number state

Li-Li Hou, Yongxing Sui, Shuai Wang +1 more

We theoretically investigate the phase sensitivity with parity measurement on a Mach–Zehnder interferometer with a coherent state combined with a squeezed number state. Within a constraint on the total mean photon number, we find, via parity measurement, that the mixing of a coherent state and squeezed number state can give better phase sensitivity than mixing a coherent state and squeezed vacuum state when the phase shift deviates from the optimal phase φ =0. In addition, we show that the classical Fisher information for parity measurement saturates the quantum Fisher information when the phase shift approaches to zero. Thus, the quantum Cramér–Rao bound can be reached via the parity measurement in the case of φ =0.

Chinese Physics B•Apr 1, 2019•10 citations
We derive a general expression of the expectation value of the parity operator in a Mach–Zehnder interferometer with a Fock state in one input port and an arbitrary state in the other input. We obtain the quantum Crámer–Rao bound via the error propagation method from parity detection for the phase shift around zero. In addition, for an arbitrary state with the same mean photon number, our results show that the same phase resolution and the same phase uncertainty can be obtained for the phase shift around zero. That is to say, when a Mach–Zehnder interferometer is powered by a Fock state into one input port, all quantum states with same mean photon number at the other input may have the same performance in the phase estimation via parity detection. As some specific applications, we consider the arbitrary state being a Fock state, a coherent state, and a squeezed-vacuum state.
We theoretically investigate the quantum enhanced metrology using two-mode squeezed twin-Fock states and parity detection. Our results indicate that, for a given initial squeezing parameter, compared with the two-mode squeezed vacuum state, both phase sensitivity and resolution can be enhanced when the two-mode squeezed twin-Fock state is considered as an input state of a Mach–Zehnder interferometer. Within a constraint on the total photon number, although the two-mode squeezed vacuum state gives the better phase sensitivity when the phase shift φ to be estimated approaches to zero, the phase sensitivity offered by these non-Gaussian entangled Gaussian states is relatively stable with respect to the phase shift itself. When the phase shift slightly deviates from φ = 0, the phase sensitivity can be still enhanced by the two-mode squeezed twin-Fock state over a broad range of the total mean photon number where the phase uncertainty is still below the quantum standard noise limit. Finally, we numerically prove that the quantum Cramér–Rao bound can be approached with the parity detection.
We study a Mach-Zehnder interferometer fed by a coherent state in one input port and vacuum in the other. We explore a Bayesian phase estimation strategy to demonstrate that it is possible to achieve the standard quantum limit independently from the true value of the phase shift and specific assumptions on the noise of the interferometer. We have been able to implement the protocol by using parallel operation of two photon-number-resolving detectors and multiphoton coincidence logic electronics at the output ports of a weakly illuminated Mach-Zehnder interferometer. This protocol is unbiased, saturates the Cramer-Rao phase uncertainty bound, and, therefore, is an optimal phase estimation strategy.
We investigate the sensitivity of phase estimation in a Mach–Zehnder interferometer with photon-subtracted two-mode squeezed vacuum states. Our results show that, for given initial squeezing parameter, both symmetric and asymmetric photon subtractions can further improve the quantum Cramér–Rao bound (i.e., the ultimate phase sensitivity), especially for single-mode photon subtraction. On the other hand, the quantum Cramér–Rao bound can be reached by parity detection for symmetric photon-subtracted two-mode squeezed vacuum states at particular values of the phase shift, but it is not valid for asymmetric photon-subtracted two-mode squeezed vacuum states. In addition, compared with the two-mode squeezed vacuum state, the phase sensitivity via parity detection with asymmetric photon-subtracted two-mode squeezed vacuum states will be getting worse. Thus, parity detection may not always be the optimal detection scheme for nonclassical states of light when they are considered as the interferometer states.
We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where NT{N}_{T}NT​ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter rrr and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.
We investigate the sensitivity and resolution of phase estimation in a Mach–Zehnder interferometer with photon-added two-mode squeezed vacuum states (PA-TMSVS) with a photon-number parity measurement scheme. Our results indicate that, when the phase to be estimated is small, the PA-TMSVS offers an improved phase resolution over both the two-mode squeezed vacuum and the photon-subtracted two-mode squeezed vacuum for a given initial squeezing level. In addition, we study the behavior of the quantum Fisher information of the PA-TMSVS, and show that the optimum phase uncertainty predicted by the corresponding Cramer–Rao bound can be achieved with a parity measurement.
We theoretically investigate the phase sensitivity with parity measurement on a Mach–Zehnder interferometer with a coherent state combined with a squeezed number state. Within a constraint on the total mean photon number, we find, via parity measurement, that the mixing of a coherent state and squeezed number state can give better phase sensitivity than mixing a coherent state and squeezed vacuum state when the phase shift deviates from the optimal phase φ =0. In addition, we show that the classical Fisher information for parity measurement saturates the quantum Fisher information when the phase shift approaches to zero. Thus, the quantum Cramér–Rao bound can be reached via the parity measurement in the case of φ =0.