Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Physics

Satellite-borne atomic clock based on diffuse laser-cooled atoms

Yan-Ling Meng, Xiaojun Jiang, Jing Wu, Meifeng Ye, Hua-Dong Cheng, Lin Li, Liang Liu

Published Sep 16, 2022• 4 citations
Publisher

Abstract

The technique of laser cooling of atoms gives an opportunity to improve the performance of atomic clocks by using laser-cooled atoms. The most successful cold atom clock, called the atomic fountain, is now widely used as the primary frequency standard in many labs. The cold atom clock for satellite applications, however, has not been reported so far due to special requirements of space applications. Here, we report the development of an engineering model of a satellite-borne cold atom clock, which satisfied all requirements of in-orbit operation. The core of the clock’s principle is the laser cooling of atoms by diffuse laser lights inside the microwave cavity. The structure of the physics package is presented, and its main parameters are also given. The principle and design of the optical bench are described. The initial test results are presented, and the possible improvements are also discussed.

DOI
10.3389/fphy.2022.985586

Related papers

Compact, Continuous-Beam, Cold-Atom Clock for Satellite Applications

H. Wang, Walter F. Buell

Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. The requirements for an atomic clock vary significantly depending on the application, and for many space systems, compactness and robust design are at a premium, and stability dominates over absolute accuracy. We report on progress with our design for a compact laser-cooled Cs- beam atomic clock suitable for satellite applications such as GPS. The basic design features a continuous, cold atomic beam extracted from a magneto-optic trap (MOT). This cold atomic beam is then to be used in a laser-pumped Ramsey clock, with the clock signal derived from either a microwave C-field or, alternatively, by Raman resonance between the Ramsey fields. In order to reduce light shifts from the MOT light and improve signal-to-noise, the atomic beam will be optically deflected and transversely cooled upon extraction from the MOT. We estimate that the shot-noise-limited stability achievable with this physics package can be 2 to 3 orders of magnitude better than current Cs-beam clocks used in satellite applications. We present our experimental progress towards a working frequency standard, including characterization of our six-beam magneto-optic cold atom trap and production and characterization of a cold atomic beam.

•Jun 30, 2002•1 citation

Cold atom microwave clock based on intracavity cooling in China space station

Siminda Deng, Wei Ren, Jingfeng Xiang +9 more

Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.

npj Microgravity•Jun 6, 2024•12 citations

In-orbit operation of an atomic clock based on laser-cooled 87Rb atoms

Liang Liu, Desheng Lü, Weibiao Chen +23 more

Abstract Atomic clocks based on laser-cooled atoms are widely used as primary frequency standards. Deploying such cold atom clocks (CACs) in space is foreseen to have many applications. Here we present tests of a CAC operating in space. In orbital microgravity, the atoms are cooled, trapped, launched, and finally detected after being interrogated by a microwave field using the Ramsey method. Perturbing influences from the orbital environment on the atoms such as varying magnetic fields and the passage of the spacecraft through Earth’s radiation belt are also controlled and mitigated. With appropriate parameters settings, closed-loop locking of the CAC is realized in orbit and an estimated short-term frequency stability close to 3.0 × 10 −13 τ −1/2 has been attained. The demonstration of the long-term operation of cold atom clock in orbit opens possibility on the applications of space-based cold atom sensors.

arXiv:1709.03256•Nature Communications•Jul 11, 2018•193 citations

Scheme for a compact cold-atom clock based on diffuse laser cooling in a cylindrical cavity

Peng Liu, Yan-Ling Meng, Jinyin Wan +5 more

We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of $24.5$ Hz with a contrast of $95.6%$ when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.

arXiv:1509.07650•Physical Review A•Dec 3, 2015•42 citations

Miniaturized Optical System for a Caesium Satellite-Borne Cold Atom Clock

Yating Wang, Meifeng Ye, Xiaojun Jiang +10 more

We present a highly stable and miniaturised optical system designed for a caesium satellite-borne cold atom clock (CSCAC). The optical system was integrated on a$224\,{\mathop{\rm mm}\nolimits} \times 195\,{\mathop{\rm mm}\nolimits} \times 112\,{\mathop{\rm mm}\nolimits} $aluminium-based silicon carbide bench and emitted laser beams with four different frequencies on three fiber ports to capture, cool, prepare, and detect atoms. The optical system, utilizing a compact three-layer optical-mechanical and thermal management design, passed environmental simulation tests and adapted to a special satellite-borne environment. The optical system stability meets the laser requirements of the clock.

IEEE photonics journal•Nov 8, 2022•3 citations

High-stability compact atomic clock based on isotropic laser cooling

François-Xavier Esnault, David Holleville, Nicolas Rossetto +2 more

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

Physical Review A•Sep 29, 2010•84 citations
The technique of laser cooling of atoms gives an opportunity to improve the performance of atomic clocks by using laser-cooled atoms. The most successful cold atom clock, called the atomic fountain, is now widely used as the primary frequency standard in many labs. The cold atom clock for satellite applications, however, has not been reported so far due to special requirements of space applications. Here, we report the development of an engineering model of a satellite-borne cold atom clock, which satisfied all requirements of in-orbit operation. The core of the clock’s principle is the laser cooling of atoms by diffuse laser lights inside the microwave cavity. The structure of the physics package is presented, and its main parameters are also given. The principle and design of the optical bench are described. The initial test results are presented, and the possible improvements are also discussed.
Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. The requirements for an atomic clock vary significantly depending on the application, and for many space systems, compactness and robust design are at a premium, and stability dominates over absolute accuracy. We report on progress with our design for a compact laser-cooled Cs- beam atomic clock suitable for satellite applications such as GPS. The basic design features a continuous, cold atomic beam extracted from a magneto-optic trap (MOT). This cold atomic beam is then to be used in a laser-pumped Ramsey clock, with the clock signal derived from either a microwave C-field or, alternatively, by Raman resonance between the Ramsey fields. In order to reduce light shifts from the MOT light and improve signal-to-noise, the atomic beam will be optically deflected and transversely cooled upon extraction from the MOT. We estimate that the shot-noise-limited stability achievable with this physics package can be 2 to 3 orders of magnitude better than current Cs-beam clocks used in satellite applications. We present our experimental progress towards a working frequency standard, including characterization of our six-beam magneto-optic cold atom trap and production and characterization of a cold atomic beam.
Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
Abstract Atomic clocks based on laser-cooled atoms are widely used as primary frequency standards. Deploying such cold atom clocks (CACs) in space is foreseen to have many applications. Here we present tests of a CAC operating in space. In orbital microgravity, the atoms are cooled, trapped, launched, and finally detected after being interrogated by a microwave field using the Ramsey method. Perturbing influences from the orbital environment on the atoms such as varying magnetic fields and the passage of the spacecraft through Earth’s radiation belt are also controlled and mitigated. With appropriate parameters settings, closed-loop locking of the CAC is realized in orbit and an estimated short-term frequency stability close to 3.0 × 10 −13 τ −1/2 has been attained. The demonstration of the long-term operation of cold atom clock in orbit opens possibility on the applications of space-based cold atom sensors.
We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of 24.524.524.5 Hz with a contrast of 95.695.6%95.6 when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.
We present a highly stable and miniaturised optical system designed for a caesium satellite-borne cold atom clock (CSCAC). The optical system was integrated on a$224\,{\mathop{\rm mm}\nolimits} \times 195\,{\mathop{\rm mm}\nolimits} \times 112\,{\mathop{\rm mm}\nolimits} $aluminium-based silicon carbide bench and emitted laser beams with four different frequencies on three fiber ports to capture, cool, prepare, and detect atoms. The optical system, utilizing a compact three-layer optical-mechanical and thermal management design, passed environmental simulation tests and adapted to a special satellite-borne environment. The optical system stability meets the laser requirements of the clock.
We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.