arXiv:1509.07650 · Physical Review A

Scheme for a compact cold-atom clock based on diffuse laser cooling in a cylindrical cavity

Peng Liu, Yan-Ling Meng, Jinyin Wan, 王秀梅 Wang Xiumei, Yaning Wang, Ling Xiao, Hua-Dong Cheng, Liang Liu

Published Dec 3, 2015• 42 citations
arXivHTMLPDF

Abstract

We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of $24.5$ Hz with a contrast of $95.6%$ when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.

DOI
10.1103/physreva.92.062101

Related papers

High-stability compact atomic clock based on isotropic laser cooling

François-Xavier Esnault, David Holleville, Nicolas Rossetto +2 more

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

Physical Review A•Sep 29, 2010•84 citations

Physics package based on intracavity laser cooling 87Rb atoms for space cold atom microwave clock

Siminda 思敏达 Deng 邓, Wei 伟 Ren 任, Jingfeng Xiang +9 more

Abstract This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation, microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2 × 10−12 τ −1/2 with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future.

Chinese Physics B•May 15, 2024•5 citations

Integrating sphere cold atom clock with cylindrical microwave cavity

Xucheng Wang, Hua-Dong Cheng, Ben-Chang Zheng +4 more

The integrating sphere is used to generate the diffuse light for cooling atoms. The microwave field is produced in a cylindrical cavity on a TE011 mode. We have realized the microwave interrogation with the pulsed optically pumped (POP) scheme. The Ramsey fringe is demonstrated and some factors to affect the signal to noise ratio (SNR) and the contrast of the fringe are discussed. Optimization of the experimental parameters is still in progress.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•1 citation

A compact cold-atom clock based on a loop-gap cavity

Sangmin Lee, Gyeong Won Choi, Hyun-Gue Hong +4 more

We introduce a compact atomic clock based on laser-cooled atoms trapped inside a loop-gap microwave cavity. The cavity occupies a volume eight times smaller than conventional cylindrical cavities while maintaining a high quality factor in the presence of the ten apertures required for optical manipulation of cold atoms. The measured linewidth of the Ramsey spectrum, which is limited by the free fall distance of the atomic cloud in the cavity, was 19.6 Hz. The corresponding frequency instability was σy(τ) = 2.5 × 10−12 τ−1/2, which could be further improved by reducing the local oscillator noise. This work paves a way toward high-performance portable atomic clocks.

Applied Physics Letters•Aug 9, 2021•16 citations

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

A compact cold atom cavity clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

Abstract A sample of laser cooled atoms are created inside an additively manufactured loop-gap microwave cavity using a grating magneto-optic trap requiring only a single laser cooling beam. Using a Ramsey excitation scheme with free evolution times of up to 20 ms and based on the 87Rb ground-state clock transition, we demonstrate a short-term stability of 1.5×10−11 τ −1/2, averaging down to 2×10−12 after 100 s. The short-term stability limit is found to be dominated by the signal to noise ratio of the Ramsey fringes while for longer timescales the limitation is magnetic field noise due to the experiment being magnetically unshielded. Potential improvements to the setup and its operation point to a viable route forward for a miniaturised atomic microwave clock.

Journal of Physics Conference Series•Nov 1, 2024•0 citations
We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of 24.524.524.5 Hz with a contrast of 95.695.6%95.6 when the free evolution time is 20 ms. Recently, a frequency stability of 7.3\ifmmode×\else\texttimes\fi10\ensuremath−13\ensuremathτ\ensuremath−1/27.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}7.3\ifmmode×\else\texttimes\fi10\ensuremath−13\ensuremathτ\ensuremath−1/2 has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.
We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.
Abstract This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation, microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2 × 10−12 τ −1/2 with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future.
We introduce a compact atomic clock based on laser-cooled atoms trapped inside a loop-gap microwave cavity. The cavity occupies a volume eight times smaller than conventional cylindrical cavities while maintaining a high quality factor in the presence of the ten apertures required for optical manipulation of cold atoms. The measured linewidth of the Ramsey spectrum, which is limited by the free fall distance of the atomic cloud in the cavity, was 19.6 Hz. The corresponding frequency instability was σy(τ) = 2.5 × 10−12 τ−1/2, which could be further improved by reducing the local oscillator noise. This work paves a way toward high-performance portable atomic clocks.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
Abstract A sample of laser cooled atoms are created inside an additively manufactured loop-gap microwave cavity using a grating magneto-optic trap requiring only a single laser cooling beam. Using a Ramsey excitation scheme with free evolution times of up to 20 ms and based on the 87Rb ground-state clock transition, we demonstrate a short-term stability of 1.5×10−11 τ −1/2, averaging down to 2×10−12 after 100 s. The short-term stability limit is found to be dominated by the signal to noise ratio of the Ramsey fringes while for longer timescales the limitation is magnetic field noise due to the experiment being magnetically unshielded. Potential improvements to the setup and its operation point to a viable route forward for a miniaturised atomic microwave clock.