A force sensor for local measurements based on trapped atom interferometry

Xavier Alauze, Alexis Bonnin, Franck Pereira dos Santos

Published Jan 7, 2018• 0 citations
OpenAlex

Related papers

Local force measurements with a trapped atom interferometer

Franck Pereira dos Santos, Yann Balland, Luc Absil

•Oct 15, 2025•0 citations

Quectonewton Local Force Sensor

Yann Balland, Luc Absil, Franck Pereira dos Santos

We report on the realization of a quantum sensor based on trapped atom interferometry in an optical lattice for the measurement of atom-surface interactions, with sub-micrometer-level control of the mean atom-surface separation distance. The force sensor reaches a short-term sensitivity of 3.4×10^{-28} N at 1 s and a long-term stability of 4 qN (4×10^{-30} N). We perform force measurements in the 0-300 μm range, and despite significant stray forces caused by adsorbed atoms on the surface, we obtain evidence of the Casimir-Polder force.

arXiv:2310.14717•Physical Review Letters•Sep 13, 2024•18 citations

Measuring short range stray electric fields with a force quantum sensor

Yann Balland, Franck Pereira dos Santos

We use a quantum sensor based on trapped atom interferometry, and designed for probing short range atom-surface interactions, to characterize parasitic electric fields produced by adsorbed atoms or surface charges on a dielectric mirror. Applying controlled external fields with in-situ electrodes allows measuring electric field gradients with a relative uncertainty of order of 1% via variations of the force induced onto the atoms. More, our sensor can also be configured as a trapped microwave clock, allowing for direct measurements of the electric field amplitude via the Stark shift of the hyperfine transition frequency. Such measurements of the electric field amplitudes and gradients as a function of the atom-surface distance can be used to construct a model for the spatial distribution of the atoms adsorbed onto the surface of the mirror, and to accurately correct local force measurements, such as related to the Casimir–Polder interaction, from the detrimental impact of adsorbed atoms or stray charges.

Comptes Rendus Physique•Oct 2, 2025•0 citations

A trapped atom interferometer for short range forces measurement

Cyrille Solaro, Alexis Bonnin, Xavier Alauze +6 more

•Mar 30, 2014•0 citations

Short range force sensing with a trapped atom interferometer

Franck Pereira dos Santos, Yann Balland, Luc Absil

•Feb 13, 2023•0 citations

Trapped atom interferometry for the study of Casimir forces and Gravitation at short range

Franck Pereira dos Santos, Xavier Alauze, Cyrille Solaro +1 more

\n We report on the recent progress on an experiment which aims at measuring shortrange forces with a high sensitivity force sensor based on trapped atominterferometry. The spatial resolution of the sensor was improved to a fewmicrons by cooling the atomic sample down to ultracold temperatures byevaporative cooling in a crossed dipole trap. Having now in hand a much denseratomic sample, we have to face deleterious effects arising from atomicinteractions, which reduce the coherence time of the interferometer. We finallypropose how to mitigate these effects in order to preserve the excellentsensitivity of the sensor.\n

•Jan 1, 2017•1 citation
We report on the realization of a quantum sensor based on trapped atom interferometry in an optical lattice for the measurement of atom-surface interactions, with sub-micrometer-level control of the mean atom-surface separation distance. The force sensor reaches a short-term sensitivity of 3.4×10^{-28} N at 1 s and a long-term stability of 4 qN (4×10^{-30} N). We perform force measurements in the 0-300 μm range, and despite significant stray forces caused by adsorbed atoms on the surface, we obtain evidence of the Casimir-Polder force.
We use a quantum sensor based on trapped atom interferometry, and designed for probing short range atom-surface interactions, to characterize parasitic electric fields produced by adsorbed atoms or surface charges on a dielectric mirror. Applying controlled external fields with in-situ electrodes allows measuring electric field gradients with a relative uncertainty of order of 1% via variations of the force induced onto the atoms. More, our sensor can also be configured as a trapped microwave clock, allowing for direct measurements of the electric field amplitude via the Stark shift of the hyperfine transition frequency. Such measurements of the electric field amplitudes and gradients as a function of the atom-surface distance can be used to construct a model for the spatial distribution of the atoms adsorbed onto the surface of the mirror, and to accurately correct local force measurements, such as related to the Casimir–Polder interaction, from the detrimental impact of adsorbed atoms or stray charges.
\n We report on the recent progress on an experiment which aims at measuring shortrange forces with a high sensitivity force sensor based on trapped atominterferometry. The spatial resolution of the sensor was improved to a fewmicrons by cooling the atomic sample down to ultracold temperatures byevaporative cooling in a crossed dipole trap. Having now in hand a much denseratomic sample, we have to face deleterious effects arising from atomicinteractions, which reduce the coherence time of the interferometer. We finallypropose how to mitigate these effects in order to preserve the excellentsensitivity of the sensor.\n