Trapped atom interferometry for the study of Casimir forces and Gravitation at short range

Franck Pereira dos Santos, Xavier Alauze, Cyrille Solaro, Alexis Bonnin

Published Jan 1, 2017• 1 citation
OpenAlex

Abstract

\n We report on the recent progress on an experiment which aims at measuring shortrange forces with a high sensitivity force sensor based on trapped atominterferometry. The spatial resolution of the sensor was improved to a fewmicrons by cooling the atomic sample down to ultracold temperatures byevaporative cooling in a crossed dipole trap. Having now in hand a much denseratomic sample, we have to face deleterious effects arising from atomicinteractions, which reduce the coherence time of the interferometer. We finallypropose how to mitigate these effects in order to preserve the excellentsensitivity of the sensor.\n

Related papers

A trapped ultracold atom force sensor with a μm-scale spatial resolution

Xavier Alauze, Alexis Bonnin, Cyrille Solaro +1 more

We report on the use of an ultracold ensemble of 87 Rb atoms trapped in a vertical lattice as a source for a quantum force sensor based on a Ramsey–Raman type interferometer. We reach spatial resolution in the low micrometer range in the vertical direction thanks to evaporative cooling down to ultracold temperatures in a crossed optical dipole trap. In this configuration, the coherence time of the atomic ensemble is degraded by inhomogeneous dephasing arising from atomic interactions. By weakening the confinement in the transverse direction only, we dilute the cloud and drastically reduce the strength of these interactions, without affecting the vertical resolution. This allows us to maintain an excellent relative sensitivity on the Bloch frequency, which is related to the local gravitational force, of 5 × 10 −6 at 1 s which integrates down to 8 × 10 −8 after one hour averaging time.

arXiv:1807.05860•New Journal of Physics•Jul 31, 2018•33 citations

Quectonewton Local Force Sensor

Yann Balland, Luc Absil, Franck Pereira dos Santos

We report on the realization of a quantum sensor based on trapped atom interferometry in an optical lattice for the measurement of atom-surface interactions, with sub-micrometer-level control of the mean atom-surface separation distance. The force sensor reaches a short-term sensitivity of 3.4×10^{-28} N at 1 s and a long-term stability of 4 qN (4×10^{-30} N). We perform force measurements in the 0-300 μm range, and despite significant stray forces caused by adsorbed atoms on the surface, we obtain evidence of the Casimir-Polder force.

arXiv:2310.14717•Physical Review Letters•Sep 13, 2024•18 citations

Probing gravity with trapped atoms: the optical lattice atom interferometer

Cristian Daniel Panda

Atom interferometers are quantum mechanical devices sensitive to gravitational and inertial forces, with applications in fundamental physics and inertial sensing in the field. Their performance is currently limited by the interrogation time available to freely falling atoms in Earth’s gravitational field, as well as noise due to mechanical and acoustic vibrations. Our experiment probes gravitational potentials by holding, rather than dropping, atoms. We realize an interrogation time of 20 seconds by suspending the spatially separated atomic wave packets in an optical lattice. This record coherence is enabled by the smooth lattice wave fronts, which are mode-filtered by an optical cavity. This trapped geometry suppresses phase variance due to vibrations by three to four orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. The later part of the talk describes recent progress in characterizing and reducing dephasing of the interferometer. An upgraded optical lattice interferometer experiment is currently being commissioned, with the goal of increased sensitivity to gravity.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Atom Interferometry with a Weakly Interacting Bose-Einstein Condensate

M. Fattori, Chiara D’Errico, G. Roati +5 more

We demonstrate the operation of an atom interferometer based on a weakly interacting Bose-Einstein condensate. We strongly reduce the interaction induced decoherence that usually limits interferometers based on trapped condensates by tuning the s-wave scattering length almost to zero via a magnetic Feshbach resonance. We employ a 39K condensate trapped in an optical lattice, where Bloch oscillations are forced by gravity. The fine-tuning of the scattering length down to 0.1 a_(0) and the micrometric sizes of the atomic sample make our system a very promising candidate for measuring forces with high spatial resolution. Our technique can be in principle extended to other measurement schemes opening new possibilities in the field of trapped atom interferometry.

arXiv:0710.5131•Physical Review Letters•Feb 28, 2008•199 citations

Atom Interferometry with Trapped Fermi Gases

G. Roati, Estefania de Mirandés, Francesca Ferlaino +3 more

We realize an interferometer with an atomic Fermi gas trapped in an optical lattice under the influence of gravity. The single-particle interference between the eigenstates of the lattice results in macroscopic Bloch oscillations of the sample. The absence of interactions between fermions allows a time-resolved study of many periods of the oscillations, leading to a sensitive determination of the acceleration of gravity. The experiment proves the superiority of noninteracting fermions with respect to bosons for precision interferometry and offers a way for the measurement of forces with microscopic spatial resolution.

arXiv:cond-mat/0402328•Physical Review Letters•Jun 8, 2004•210 citations

Quantum sensor for atom-surface interactions below 10μm

Fiodor Sorrentino, Andrea Alberti, G. Ferrari +4 more

We report the realization of a quantum device for force sensing at the micrometric scale. We trap an ultracold $^{88}\mathrm{Sr}$ atomic cloud with a one-dimensional (1D) optical lattice; then we place the atomic sample close to a test surface using the same optical lattice as an elevator. We demonstrate precise positioning of the sample at the micrometer scale. By observing the Bloch oscillations of atoms into the 1D optical standing wave, we are able to measure the total force on the atoms along the lattice axis, with a spatial resolution of few micrometers. We also demonstrate a technique for transverse displacement of the atoms, allowing us to perform measurements near either transparent or reflective test surfaces. In order to reduce the minimum distance from the surface, we compress the longitudinal size of the atomic sample by means of an optical tweezer. This system is suited for studies of atom-surface interaction at short distance, such as measurement of the Casimir force and the search for possible non-Newtonian gravity effects.

arXiv:0811.0878•Physical Review A•Jan 9, 2009•64 citations
\n We report on the recent progress on an experiment which aims at measuring shortrange forces with a high sensitivity force sensor based on trapped atominterferometry. The spatial resolution of the sensor was improved to a fewmicrons by cooling the atomic sample down to ultracold temperatures byevaporative cooling in a crossed dipole trap. Having now in hand a much denseratomic sample, we have to face deleterious effects arising from atomicinteractions, which reduce the coherence time of the interferometer. We finallypropose how to mitigate these effects in order to preserve the excellentsensitivity of the sensor.\n
We report on the use of an ultracold ensemble of 87 Rb atoms trapped in a vertical lattice as a source for a quantum force sensor based on a Ramsey–Raman type interferometer. We reach spatial resolution in the low micrometer range in the vertical direction thanks to evaporative cooling down to ultracold temperatures in a crossed optical dipole trap. In this configuration, the coherence time of the atomic ensemble is degraded by inhomogeneous dephasing arising from atomic interactions. By weakening the confinement in the transverse direction only, we dilute the cloud and drastically reduce the strength of these interactions, without affecting the vertical resolution. This allows us to maintain an excellent relative sensitivity on the Bloch frequency, which is related to the local gravitational force, of 5 × 10 −6 at 1 s which integrates down to 8 × 10 −8 after one hour averaging time.
We report on the realization of a quantum sensor based on trapped atom interferometry in an optical lattice for the measurement of atom-surface interactions, with sub-micrometer-level control of the mean atom-surface separation distance. The force sensor reaches a short-term sensitivity of 3.4×10^{-28} N at 1 s and a long-term stability of 4 qN (4×10^{-30} N). We perform force measurements in the 0-300 μm range, and despite significant stray forces caused by adsorbed atoms on the surface, we obtain evidence of the Casimir-Polder force.
Atom interferometers are quantum mechanical devices sensitive to gravitational and inertial forces, with applications in fundamental physics and inertial sensing in the field. Their performance is currently limited by the interrogation time available to freely falling atoms in Earth’s gravitational field, as well as noise due to mechanical and acoustic vibrations. Our experiment probes gravitational potentials by holding, rather than dropping, atoms. We realize an interrogation time of 20 seconds by suspending the spatially separated atomic wave packets in an optical lattice. This record coherence is enabled by the smooth lattice wave fronts, which are mode-filtered by an optical cavity. This trapped geometry suppresses phase variance due to vibrations by three to four orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. The later part of the talk describes recent progress in characterizing and reducing dephasing of the interferometer. An upgraded optical lattice interferometer experiment is currently being commissioned, with the goal of increased sensitivity to gravity.
We demonstrate the operation of an atom interferometer based on a weakly interacting Bose-Einstein condensate. We strongly reduce the interaction induced decoherence that usually limits interferometers based on trapped condensates by tuning the s-wave scattering length almost to zero via a magnetic Feshbach resonance. We employ a 39K condensate trapped in an optical lattice, where Bloch oscillations are forced by gravity. The fine-tuning of the scattering length down to 0.1 a_(0) and the micrometric sizes of the atomic sample make our system a very promising candidate for measuring forces with high spatial resolution. Our technique can be in principle extended to other measurement schemes opening new possibilities in the field of trapped atom interferometry.
We realize an interferometer with an atomic Fermi gas trapped in an optical lattice under the influence of gravity. The single-particle interference between the eigenstates of the lattice results in macroscopic Bloch oscillations of the sample. The absence of interactions between fermions allows a time-resolved study of many periods of the oscillations, leading to a sensitive determination of the acceleration of gravity. The experiment proves the superiority of noninteracting fermions with respect to bosons for precision interferometry and offers a way for the measurement of forces with microscopic spatial resolution.
We report the realization of a quantum device for force sensing at the micrometric scale. We trap an ultracold 88Sr^{88}\mathrm{Sr}88Sr atomic cloud with a one-dimensional (1D) optical lattice; then we place the atomic sample close to a test surface using the same optical lattice as an elevator. We demonstrate precise positioning of the sample at the micrometer scale. By observing the Bloch oscillations of atoms into the 1D optical standing wave, we are able to measure the total force on the atoms along the lattice axis, with a spatial resolution of few micrometers. We also demonstrate a technique for transverse displacement of the atoms, allowing us to perform measurements near either transparent or reflective test surfaces. In order to reduce the minimum distance from the surface, we compress the longitudinal size of the atomic sample by means of an optical tweezer. This system is suited for studies of atom-surface interaction at short distance, such as measurement of the Casimir force and the search for possible non-Newtonian gravity effects.