We show that the electron-positron annihilation process resulting with the creation of two gamma photons cannot be fully determined without the conservation of the angular momentum which has two elements, namely, the conservation of the spin angular momentum and the conservation of the quantum flux which work as the conservation of the magnetic moments as well. The conservation of the quantum flux has never been considered so far for any collision process. We show that the missing conservation rule in the above process is the conservation of the total quantum flux which is the hidden variable of that process. By using the quantum entanglement together with the conservation of the quantum flux we show that the initial and the final states of this collision are fully determined. We also show that each of the gamma photons created in the end carries a quantum flux of ±Φ=±hc/e with itself along the propagation direction. Here the (+) and (−) signs correspond to the right hand and left circular helicity, respectively.
When a positron/electron pair annihilate via the two-photon pathway, the emitted photons are momentum correlated. This correlation ensures that they move along a straight line path in opposite directions. An experiment performed in 2004 by Dr. V.D. Irby measured the time interval between \ndetection of the photons. He observed a decay in the number of counts with increasing detection time interval, which he described using a Lorentzian, the line width of which at full-width half-maximum is \nmeasured to be 120ps. The data collected by Irby is interesting because current theory predicts that because the source is so localized (the effective source width used by Irby is safely within 5rnrn) the photons should be detected within a time interval of ?t=d/c where d is the thickness of the source. This time interval corresponds to 17ps. This thesis fits the results to an exponential, and shows that this exponentially decaying nature of the coincidence time interval is characteristic of the entanglement of the two photons. We find that the wavefunctions of the photons decoheres in space according to how long the particle pair took to decay (which is exponential), and that the probability of simultaneous \ndetection depends on the exponential of the product of the lifetime of positronium and the detection time interval.
The entanglement of photons originating from electron-positron annihilation has not been experimentally proven.owever, the independent experiments performed so far unanimously confirm that the correlation between the linear polarizations of back-to-back photons from electron-positron annihilation is consistent with the assumption that these photons are entangled in the polarization.Yet, unexpectedly, recent experiments differ as regards the correlation of polarization direction of back-to-back photons after the decoherence induced by the scattering of one of these photons on the electron in the scattering material.In one of the experiments, the correlation before and after the decoherence of the photon state is the same, and in the other experiment, the scattering of one photon leads to a significant decrease in this correlation.Here we discuss this puzzle.Decoherent states were ensured provided by forcing one of the annihilation photons to scatter earlier before measuring the polarization correlation based on Compton kinematics.The comparison is made between the experimental setups used for the different measurements, and the results obtained are briefly discussed, highlighting the parameters that are important in performing such measurements.Finally, the main features of the J-PET detector are presented, along with the schemes for performing similar studies, so that the conclusive results can be used as remarks to solve the puzzle in question.Solving the decoherence puzzle will have crucial consequences for basic studies of entanglement, as well as for the proposed application of the photon polarization in positron emission tomography.If the correlation of the polarization of back-to-back photons from the electron-positron annihilation is the same before and after the scattering of these photons, then it will not be useful for the reduction of scatter fraction in positron emission tomography diagnostics.
Abstract The experimental setup for study of Compton scattering of entangled and decoherent annihilation gammas is described. These gammas are born in two-photon positron-electron annihilation. Polarizations of annihilation gammas are mutually orthogonal, while the polarization of each photon is indefinite. If one of the photons of the pair interacts with matter, the pair becomes decoherent and photons acquire the determined polarization states. The kinematics of Compton scattering depends on the polarization states and can be different for entangled and decoherent pairs of annihilation photons. The angular correlations of scattered gammas for both, entangled and decoherent states are measured and compared. It is shown, that the kinematics of Compton scattering are similar for both cases.
Abstract In the positron–electron annihilation process, finite deviations from the standard calculation based on Fermi’s golden rule are suggested in recent theoretical work. This paper describes an experimental test of the predictions of this theoretical work by searching for events with two photons from positron annihilation of energy larger than the electron rest mass (
511keV). The positrons came from a
22Na source, tagging the third photon from the spontaneous emission of
22Ne∗ de-exitation to suppress backgrounds. Using the collected sample of
1.06×107 positron–electron annihilations, triple coincidence photon events in the signal-enhanced energy regions are examined. The observed number of events in two signal regions,
NobsSR1=0 and
NobsSR2=0, are, within the current precision, consistent with the expected number of events,
NexpSR1=0.86±0.08(stat.)−0.81+1.85(syst.) and
NexpSR2=0.37±0.05(stat.)−0.29+0.80(syst.) from Fermi’s golden rule, respectively. Based on the