Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Theory of Computing Systems

Positron/Electron Annihilation via the Two-Photon Pathway

Isabelle Gauthier

Published Jan 1, 2011• 0 citations
OpenAlex

Abstract

When a positron/electron pair annihilate via the two-photon pathway, the emitted photons are momentum correlated. This correlation ensures that they move along a straight line path in opposite directions. An experiment performed in 2004 by Dr. V.D. Irby measured the time interval between \ndetection of the photons. He observed a decay in the number of counts with increasing detection time interval, which he described using a Lorentzian, the line width of which at full-width half-maximum is \nmeasured to be 120ps. The data collected by Irby is interesting because current theory predicts that because the source is so localized (the effective source width used by Irby is safely within 5rnrn) the photons should be detected within a time interval of ?t=d/c where d is the thickness of the source. This time interval corresponds to 17ps. This thesis fits the results to an exponential, and shows that this exponentially decaying nature of the coincidence time interval is characteristic of the entanglement of the two photons. We find that the wavefunctions of the photons decoheres in space according to how long the particle pair took to decay (which is exponential), and that the probability of simultaneous \ndetection depends on the exponential of the product of the lifetime of positronium and the detection time interval.

Related papers

Photon correlations in positron annihilation

Isabelle Gauthier, Margaret Hawton

The two-photon positron annihilation density matrix is found to separate into a diagonal center-of-energy factor implying maximally entangled momenta, and a relative factor describing decay. For unknown positron injection time, the distribution of the difference in photon arrival times is a double exponential at the para-Ps decay rate, consistent with experiment [V. D. Irby, Meas. Sci. Technol. 15, 1799 (2004)].

arXiv:1006.0665•Physical Review A•Jun 23, 2010•6 citations

Quantum Entanglement from Positronium Decay

Forrest Bullard

IntroductionIn this experiment we will explore whether photons emitted from the decay of positronium, a positron-electron composition, are quantum entangled. When talking about quantum entangled particles it is impossible to fully represent the quantum state of one particle independently of another such that if we know one photon from an entangled pair is horizontally polarized then the other must be vertically polarized. We will use this concept along with knowledge from previous experiments on positron-electron annihilation and Compton scattering to try to determine the truth of this model.ProcedureIn this experiment we used two NaI detectors, photo-multiplier tubes (PMT), pre-amplifiers, and amplifiers. Along with two single channel analyzers, a logic gate, a coincidence detector, a high-voltage supply, and a multi-channel analyzer (MCA) and of course two aluminum targets, a sodium-22 radioactive source, and loads of lead bricks. Our source was encased in the center of our detector configuration such that radiation from the source was focused towards both aluminum targets placed opposite of each other with respect to the source. Both detectors were then stationed so that photons coming from the source were detected after a 90 degree Compton scattering from the target. This ninety degree correlation is necessary for proof of quantum entanglement as we expect no coincidences to occur when both detectors are in the same plane do to quantum pairs anti-correlated polarization causing expected scattering to be related by this ninety degree angle. The picture below shows the basic geometry of this set up.

•Dec 14, 2020•0 citations

Entangled photons from para-positronium decay: Do coincidences from scattered photons imply a Bell state?

Paul Joos, Peter Kling

Electron and positron can form a meta-stable bound state called positronium that decays via pair annihilation. We show how polarization-dependent Compton scattering can be used to verify that the two annihilation photons in the spin-zero case (para-positronium) are emitted in a maximally entangled Bell state. Our theoretical approach based on two-photon density matrices connects concepts from relativistic quantum electrodynamics and quantum information theory.

quant-pharXiv:2606.31726•Jul 1, 2026•1 citation

Physical limitations on quantum nonlocality in the detection of photons emitted from positron-electron annihilation

Victor D. Irby

Recent experimental measurements of the time interval between detection of the two photons emitted in positron-electron annihilation have indicated that collapse of the spatial part of the photon's wave function, due to detection of the other photon, does not occur. Although quantum nonlocality actually occurs in photons produced through parametric down-conversion, the recent experiments give strong evidence against measurement-induced instantaneous spatial localization of high-energy $\ensuremath{\gamma}$ photons. A quantum-mechanical analysis of the Einstein-Podolsky-Rosen problem is presented, which may help to explain the observed differences between photons produced through parametric down-conversion and photons produced through positron-electron annihilation. The results are found to concur with the recent experiments involving $\ensuremath{\gamma}$ photons.

arXiv:quant-ph/0209158•Physical Review A•Mar 17, 2003•12 citations

Correlations and Physical Locality

Arthur I. Fine

Correlations between the behavior of pairs of particles are generated in the following experimental situation. An on-line source emits a stream of two-particle systems, where each system is in one and the same quantum state. After emission, the particles – call then (I) and (II) – move off in opposite directions. Each particle then encounters one of several possible barriers that either it passes or doesn't. A short distance behind each barrier is a detector set to register the presence of the particle, should it get that far. Finally, the detectors are connected by a timed relay and counter that registers a “coincidence count” should the two detectors fire within a set, brief time interval. When the experiment is run with various different barriers, detection rates accumulate for each barrier singly, and coincidence rates (the correlations) for the various pairs of barriers.

PSA Proceedings of the Biennial Meeting of the Philosophy of Science Association•Jan 1, 1980•51 citations

Decoherence Puzzle in Measurements of Photons Originating from Electron-Positron Annihilation

Sushil K. Sharma, Divya Kumar, Paweł Moskal

The entanglement of photons originating from electron-positron annihilation has not been experimentally proven.owever, the independent experiments performed so far unanimously confirm that the correlation between the linear polarizations of back-to-back photons from electron-positron annihilation is consistent with the assumption that these photons are entangled in the polarization.Yet, unexpectedly, recent experiments differ as regards the correlation of polarization direction of back-to-back photons after the decoherence induced by the scattering of one of these photons on the electron in the scattering material.In one of the experiments, the correlation before and after the decoherence of the photon state is the same, and in the other experiment, the scattering of one photon leads to a significant decrease in this correlation.Here we discuss this puzzle.Decoherent states were ensured provided by forcing one of the annihilation photons to scatter earlier before measuring the polarization correlation based on Compton kinematics.The comparison is made between the experimental setups used for the different measurements, and the results obtained are briefly discussed, highlighting the parameters that are important in performing such measurements.Finally, the main features of the J-PET detector are presented, along with the schemes for performing similar studies, so that the conclusive results can be used as remarks to solve the puzzle in question.Solving the decoherence puzzle will have crucial consequences for basic studies of entanglement, as well as for the proposed application of the photon polarization in positron emission tomography.If the correlation of the polarization of back-to-back photons from the electron-positron annihilation is the same before and after the scattering of these photons, then it will not be useful for the reduction of scatter fraction in positron emission tomography diagnostics.

arXiv:2210.08541•Acta Physica Polonica A•Sep 1, 2022•18 citations
When a positron/electron pair annihilate via the two-photon pathway, the emitted photons are momentum correlated. This correlation ensures that they move along a straight line path in opposite directions. An experiment performed in 2004 by Dr. V.D. Irby measured the time interval between \ndetection of the photons. He observed a decay in the number of counts with increasing detection time interval, which he described using a Lorentzian, the line width of which at full-width half-maximum is \nmeasured to be 120ps. The data collected by Irby is interesting because current theory predicts that because the source is so localized (the effective source width used by Irby is safely within 5rnrn) the photons should be detected within a time interval of ?t=d/c where d is the thickness of the source. This time interval corresponds to 17ps. This thesis fits the results to an exponential, and shows that this exponentially decaying nature of the coincidence time interval is characteristic of the entanglement of the two photons. We find that the wavefunctions of the photons decoheres in space according to how long the particle pair took to decay (which is exponential), and that the probability of simultaneous \ndetection depends on the exponential of the product of the lifetime of positronium and the detection time interval.
IntroductionIn this experiment we will explore whether photons emitted from the decay of positronium, a positron-electron composition, are quantum entangled. When talking about quantum entangled particles it is impossible to fully represent the quantum state of one particle independently of another such that if we know one photon from an entangled pair is horizontally polarized then the other must be vertically polarized. We will use this concept along with knowledge from previous experiments on positron-electron annihilation and Compton scattering to try to determine the truth of this model.ProcedureIn this experiment we used two NaI detectors, photo-multiplier tubes (PMT), pre-amplifiers, and amplifiers. Along with two single channel analyzers, a logic gate, a coincidence detector, a high-voltage supply, and a multi-channel analyzer (MCA) and of course two aluminum targets, a sodium-22 radioactive source, and loads of lead bricks. Our source was encased in the center of our detector configuration such that radiation from the source was focused towards both aluminum targets placed opposite of each other with respect to the source. Both detectors were then stationed so that photons coming from the source were detected after a 90 degree Compton scattering from the target. This ninety degree correlation is necessary for proof of quantum entanglement as we expect no coincidences to occur when both detectors are in the same plane do to quantum pairs anti-correlated polarization causing expected scattering to be related by this ninety degree angle. The picture below shows the basic geometry of this set up.
Recent experimental measurements of the time interval between detection of the two photons emitted in positron-electron annihilation have indicated that collapse of the spatial part of the photon's wave function, due to detection of the other photon, does not occur. Although quantum nonlocality actually occurs in photons produced through parametric down-conversion, the recent experiments give strong evidence against measurement-induced instantaneous spatial localization of high-energy $\ensuremath{\gamma}$ photons. A quantum-mechanical analysis of the Einstein-Podolsky-Rosen problem is presented, which may help to explain the observed differences between photons produced through parametric down-conversion and photons produced through positron-electron annihilation. The results are found to concur with the recent experiments involving $\ensuremath{\gamma}$ photons.
Correlations between the behavior of pairs of particles are generated in the following experimental situation. An on-line source emits a stream of two-particle systems, where each system is in one and the same quantum state. After emission, the particles – call then (I) and (II) – move off in opposite directions. Each particle then encounters one of several possible barriers that either it passes or doesn't. A short distance behind each barrier is a detector set to register the presence of the particle, should it get that far. Finally, the detectors are connected by a timed relay and counter that registers a “coincidence count” should the two detectors fire within a set, brief time interval. When the experiment is run with various different barriers, detection rates accumulate for each barrier singly, and coincidence rates (the correlations) for the various pairs of barriers.
The entanglement of photons originating from electron-positron annihilation has not been experimentally proven.owever, the independent experiments performed so far unanimously confirm that the correlation between the linear polarizations of back-to-back photons from electron-positron annihilation is consistent with the assumption that these photons are entangled in the polarization.Yet, unexpectedly, recent experiments differ as regards the correlation of polarization direction of back-to-back photons after the decoherence induced by the scattering of one of these photons on the electron in the scattering material.In one of the experiments, the correlation before and after the decoherence of the photon state is the same, and in the other experiment, the scattering of one photon leads to a significant decrease in this correlation.Here we discuss this puzzle.Decoherent states were ensured provided by forcing one of the annihilation photons to scatter earlier before measuring the polarization correlation based on Compton kinematics.The comparison is made between the experimental setups used for the different measurements, and the results obtained are briefly discussed, highlighting the parameters that are important in performing such measurements.Finally, the main features of the J-PET detector are presented, along with the schemes for performing similar studies, so that the conclusive results can be used as remarks to solve the puzzle in question.Solving the decoherence puzzle will have crucial consequences for basic studies of entanglement, as well as for the proposed application of the photon polarization in positron emission tomography.If the correlation of the polarization of back-to-back photons from the electron-positron annihilation is the same before and after the scattering of these photons, then it will not be useful for the reduction of scatter fraction in positron emission tomography diagnostics.