Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou, Eric Zhu, E. W. Hagley

Published Jan 1, 2018• 0 citations
Publisher

Abstract

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.
DOI
10.1364/cleopr.2018.th3l.5

Related papers

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

Conference on Lasers and Electro-Optics•Jan 1, 2018•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

OSA Advanced Photonics Congress•Jan 1, 2018•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Optical Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an optical wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without magnetic field shielding, zero-field compensation, or RF-modulation spectroscopy.

Frontiers in Optics•Jan 1, 2017•0 citations

Nanotesla-level, shield-less, field-compensation-free, wave-mixing-enhanced body-temperature atomic magnetometry for biomagnetism

Feng Lei Zhou, Eric Y. Zhu, Yvonne Y. Li +2 more

We report an optical inelastic-wave-mixing-enhanced atomic magnetometry technique that results in nT-level magnetic field detection at temperatures compatible with the human body without magnetic shielding, zero-field compensation, or high-frequency modulated phase-locking spectroscopy. Using Gaussian magnetic pulses that mimic the transient magnetic field produced by an action potential on a frog's nerve, we demonstrate more than 300,000-fold (550-fold) enhancement of magneto-optical rotation signal power spectral-density (power amplitude) over the conventional single-beam $Λ-$scheme atomic magnetometry method. This new technique may bring possibilities for extremely sensitive magnetic field imaging of biological systems accessible via an optical fiber in clinical environments.

arXiv:1804.08194•Apr 22, 2018•1 citation

Giant Enhancement in Nonlinear Optical-Atomic Magnetometry

Lu Deng, Feng Lei Zhou, E. W. Hagley

We demonstrate a cross-polarization wave-mixing nonlinear atomic magnetometer that results in >500X optical signal signal-to-noise ratio enhancement with perfect field sensitivity preservation and significant reduction of laser power, opening a myriad of applications in bio-magnetism.

Frontiers in Optics•Jan 1, 2016•0 citations

Rapid atomic-signal-based in-situ magnetic compensation for unshielded spin-exchange relaxation-free atomic magnetometer

Jianjun Li, Haidong Wang, Teng Wu +2 more

We propose a novel method, which leverages the atomic signal itself, to achieve rapid in situ magnetic field compensation in an unknown geomagnetic environment for an unshielded spin-exchange relaxation-free atomic magnetometer. This method employs a strong bias magnetic field aligned with the pump beam direction to maximize the strength of the magnetic field resonance signal. The compensation process is divided into three sequential stages, each focusing on one of the x, y, and z axes by adjusting the magnitude of the bias magnetic field. As a result, the zero magnetic field is identified within 11 seconds, with compensation resolution smaller than 3.0 nT, primarily constrained by the laser power stability. This approach not only enhances the applicability of atomic magnetometers in unshielded environment but also proves effective for in situ magnetic field compensation in shielded environment, such as those used in magnetoencephalography, magnetocardiography, and space science.

Review of Scientific Instruments•Feb 1, 2026•0 citations
We report an optical inelastic-wave-mixing-enhanced atomic magnetometry technique that results in nT-level magnetic field detection at temperatures compatible with the human body without magnetic shielding, zero-field compensation, or high-frequency modulated phase-locking spectroscopy. Using Gaussian magnetic pulses that mimic the transient magnetic field produced by an action potential on a frog's nerve, we demonstrate more than 300,000-fold (550-fold) enhancement of magneto-optical rotation signal power spectral-density (power amplitude) over the conventional single-beam Λ−Λ-Λ−scheme atomic magnetometry method. This new technique may bring possibilities for extremely sensitive magnetic field imaging of biological systems accessible via an optical fiber in clinical environments.
We propose a novel method, which leverages the atomic signal itself, to achieve rapid in situ magnetic field compensation in an unknown geomagnetic environment for an unshielded spin-exchange relaxation-free atomic magnetometer. This method employs a strong bias magnetic field aligned with the pump beam direction to maximize the strength of the magnetic field resonance signal. The compensation process is divided into three sequential stages, each focusing on one of the x, y, and z axes by adjusting the magnitude of the bias magnetic field. As a result, the zero magnetic field is identified within 11 seconds, with compensation resolution smaller than 3.0 nT, primarily constrained by the laser power stability. This approach not only enhances the applicability of atomic magnetometers in unshielded environment but also proves effective for in situ magnetic field compensation in shielded environment, such as those used in magnetoencephalography, magnetocardiography, and space science.