Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1804.08194

Nanotesla-level, shield-less, field-compensation-free, wave-mixing-enhanced body-temperature atomic magnetometry for biomagnetism

Feng Lei Zhou, Eric Y. Zhu, Yvonne Y. Li, E. W. Hagley, L. Deng

Published Apr 22, 2018• 1 citation
arXivHTMLPDF

Abstract

We report an optical inelastic-wave-mixing-enhanced atomic magnetometry technique that results in nT-level magnetic field detection at temperatures compatible with the human body without magnetic shielding, zero-field compensation, or high-frequency modulated phase-locking spectroscopy. Using Gaussian magnetic pulses that mimic the transient magnetic field produced by an action potential on a frog's nerve, we demonstrate more than 300,000-fold (550-fold) enhancement of magneto-optical rotation signal power spectral-density (power amplitude) over the conventional single-beam $Λ-$scheme atomic magnetometry method. This new technique may bring possibilities for extremely sensitive magnetic field imaging of biological systems accessible via an optical fiber in clinical environments.

DOI
10.48550/arxiv.1804.08194

Related papers

Sub-nano-Tesla, Shield-less, Field Compensation-Free Optical Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an optical wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without magnetic field shielding, zero-field compensation, or RF-modulation spectroscopy.

Frontiers in Optics•Jan 1, 2017•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

OSA Advanced Photonics Congress•Jan 1, 2018•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

Conference on Lasers and Electro-Optics•Jan 1, 2018•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jan 1, 2018•0 citations

Symmetry-breaking inelastic wave-mixing atomic magnetometry

Feng Lei Zhou, Chengjie Zhu, E. W. Hagley +1 more

The nonlinear magneto-optical rotation (NMOR) effect has prolific applications ranging from precision mapping of Earth's magnetic field to biomagnetic sensing. Studies on collisional spin relaxation effects have led to ultrahigh magnetic field sensitivities using a single-beam Λ scheme with state-of-the-art magnetic shielding/compensation techniques. However, the NMOR effect in this widely used single-beam Λ scheme is peculiarly small, requiring complex radio-frequency phase-locking protocols. We show the presence of a previously unknown energy symmetry-based nonlinear propagation blockade and demonstrate an optical inelastic wave-mixing NMOR technique that breaks this NMOR blockade, resulting in an NMOR optical signal-to-noise ratio (SNR) enhancement of more than two orders of magnitude never before seen with the single-beam Λ scheme. The large SNR enhancement was achieved simultaneously with a nearly two orders of magnitude reduction in laser power while preserving the magnetic resonance linewidth. This new method may open a myriad of applications ranging from biomagnetic imaging to precision measurement of the magnetic properties of subatomic particles.

arXiv:1609.00431•Science Advances•Dec 1, 2017•24 citations

Rapid atomic-signal-based in-situ magnetic compensation for unshielded spin-exchange relaxation-free atomic magnetometer

Jianjun Li, Haidong Wang, Teng Wu +2 more

We propose a novel method, which leverages the atomic signal itself, to achieve rapid in situ magnetic field compensation in an unknown geomagnetic environment for an unshielded spin-exchange relaxation-free atomic magnetometer. This method employs a strong bias magnetic field aligned with the pump beam direction to maximize the strength of the magnetic field resonance signal. The compensation process is divided into three sequential stages, each focusing on one of the x, y, and z axes by adjusting the magnitude of the bias magnetic field. As a result, the zero magnetic field is identified within 11 seconds, with compensation resolution smaller than 3.0 nT, primarily constrained by the laser power stability. This approach not only enhances the applicability of atomic magnetometers in unshielded environment but also proves effective for in situ magnetic field compensation in shielded environment, such as those used in magnetoencephalography, magnetocardiography, and space science.

Review of Scientific Instruments•Feb 1, 2026•0 citations
We report an optical inelastic-wave-mixing-enhanced atomic magnetometry technique that results in nT-level magnetic field detection at temperatures compatible with the human body without magnetic shielding, zero-field compensation, or high-frequency modulated phase-locking spectroscopy. Using Gaussian magnetic pulses that mimic the transient magnetic field produced by an action potential on a frog's nerve, we demonstrate more than 300,000-fold (550-fold) enhancement of magneto-optical rotation signal power spectral-density (power amplitude) over the conventional single-beam Λ−Λ-Λ−scheme atomic magnetometry method. This new technique may bring possibilities for extremely sensitive magnetic field imaging of biological systems accessible via an optical fiber in clinical environments.
The nonlinear magneto-optical rotation (NMOR) effect has prolific applications ranging from precision mapping of Earth's magnetic field to biomagnetic sensing. Studies on collisional spin relaxation effects have led to ultrahigh magnetic field sensitivities using a single-beam Λ scheme with state-of-the-art magnetic shielding/compensation techniques. However, the NMOR effect in this widely used single-beam Λ scheme is peculiarly small, requiring complex radio-frequency phase-locking protocols. We show the presence of a previously unknown energy symmetry-based nonlinear propagation blockade and demonstrate an optical inelastic wave-mixing NMOR technique that breaks this NMOR blockade, resulting in an NMOR optical signal-to-noise ratio (SNR) enhancement of more than two orders of magnitude never before seen with the single-beam Λ scheme. The large SNR enhancement was achieved simultaneously with a nearly two orders of magnitude reduction in laser power while preserving the magnetic resonance linewidth. This new method may open a myriad of applications ranging from biomagnetic imaging to precision measurement of the magnetic properties of subatomic particles.
We propose a novel method, which leverages the atomic signal itself, to achieve rapid in situ magnetic field compensation in an unknown geomagnetic environment for an unshielded spin-exchange relaxation-free atomic magnetometer. This method employs a strong bias magnetic field aligned with the pump beam direction to maximize the strength of the magnetic field resonance signal. The compensation process is divided into three sequential stages, each focusing on one of the x, y, and z axes by adjusting the magnitude of the bias magnetic field. As a result, the zero magnetic field is identified within 11 seconds, with compensation resolution smaller than 3.0 nT, primarily constrained by the laser power stability. This approach not only enhances the applicability of atomic magnetometers in unshielded environment but also proves effective for in situ magnetic field compensation in shielded environment, such as those used in magnetoencephalography, magnetocardiography, and space science.