Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Science

Probing Atomic Magnetism

Published Oct 14, 2004• 0 citations
Publisher
DOI
10.1126/science.306.5695.369d

Related papers

Probing and controlling quantum magnetism with ultra-cold atoms

Ana María Rey

Bulletin of the American Physical Society•Mar 12, 2008•0 citations

Biaxial zero-field atomic magnetometer with a multi-passed probe light

Yibo Qi, Shuying Wang, Nuozhou Xu +3 more

Multi-passed probe light can enhance the signal of atomic magnetometers by increasing the effective optical path length between the alkali metal atomic ensemble and the probe light, thereby strengthening the sensitivity. In recent years, multi-passed probe light has become an important method for improving the response signal and sensitivity of atomic magnetometers. To achieve biaxial magnetic field measurement while maintaining high sensitivity, a biaxial measurement spin-exchange relaxation-free (SERF) atomic magnetometer with a multi-passed probe light is proposed in this paper. The theoretical model and experimental advantages of using multi-passed probe light in longitudinal magnetic field modulation (Z-mode) SERF atomic magnetometers are analyzed. In this paper, a new model of output response of the Z-mode SERF atomic magnetometer based on multi-passed probe light is established, a compact reflective optical path is designed to increase the optical path between the probe light and the polarized alkali metal atomic ensemble, enhance the signal response, and achieve the suppression of low-frequency 1/f noise through longitudinal magnetic field modulation. Experimental results confirmed that the magnetic field sensitivity in the x- and y-axis of the multi-passed probe light configuration improved by 29% and 18%, respectively, compared to the single-pass configuration.

Optics Young Scientist Summit (OYSS)•Jan 22, 2025•0 citations

Cold Atom Magnetism

Science•Sep 17, 2009•0 citations

The suppression of the probe laser pumping effect in SERF atomic magnetometer

Qian Cao, Yueyang Zhai, Binyue Huang +2 more

Introduction: A spin exchange relaxation free atomic magnetometer, as an ultra-highly sensitive magnetic field sensor, is limited by the performance of the probe laser system. The probe laser pumping effect (PLPE) hinders the increase in the performance of probe laser system. Methods: This study investigated the PLPE and proposed a method for suppressing the same. Through changes to the angle of a quarter wave plate and the addition of a triangular modulated magnetic field to the alkali atoms, the suppression point was determined. Results and discussion: Further, related parameters were measured for different degree of polarizations of the probe laser, which confirmed that the influence of PLPE on the magnetic field was the least at the suppressed point.

Frontiers in Physics•Jun 1, 2023•1 citation

Studying magnetism with cold atoms

J. Stajic

Science•Sep 18, 2014•0 citations

Quantum Magnetism

Ulrich Schollwöck, Johannes Richter, DAMIAN J. J. FARNELL +1 more

Lecture notes in physics•Jan 1, 2004•166 citations
Multi-passed probe light can enhance the signal of atomic magnetometers by increasing the effective optical path length between the alkali metal atomic ensemble and the probe light, thereby strengthening the sensitivity. In recent years, multi-passed probe light has become an important method for improving the response signal and sensitivity of atomic magnetometers. To achieve biaxial magnetic field measurement while maintaining high sensitivity, a biaxial measurement spin-exchange relaxation-free (SERF) atomic magnetometer with a multi-passed probe light is proposed in this paper. The theoretical model and experimental advantages of using multi-passed probe light in longitudinal magnetic field modulation (Z-mode) SERF atomic magnetometers are analyzed. In this paper, a new model of output response of the Z-mode SERF atomic magnetometer based on multi-passed probe light is established, a compact reflective optical path is designed to increase the optical path between the probe light and the polarized alkali metal atomic ensemble, enhance the signal response, and achieve the suppression of low-frequency 1/f noise through longitudinal magnetic field modulation. Experimental results confirmed that the magnetic field sensitivity in the x- and y-axis of the multi-passed probe light configuration improved by 29% and 18%, respectively, compared to the single-pass configuration.
Introduction: A spin exchange relaxation free atomic magnetometer, as an ultra-highly sensitive magnetic field sensor, is limited by the performance of the probe laser system. The probe laser pumping effect (PLPE) hinders the increase in the performance of probe laser system. Methods: This study investigated the PLPE and proposed a method for suppressing the same. Through changes to the angle of a quarter wave plate and the addition of a triangular modulated magnetic field to the alkali atoms, the suppression point was determined. Results and discussion: Further, related parameters were measured for different degree of polarizations of the probe laser, which confirmed that the influence of PLPE on the magnetic field was the least at the suppressed point.