Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Physics

The suppression of the probe laser pumping effect in SERF atomic magnetometer

Qian Cao, Yueyang Zhai, Binyue Huang, Renjie Li, Jiajie Li

Published Jun 1, 2023• 1 citation
Publisher

Abstract

Introduction: A spin exchange relaxation free atomic magnetometer, as an ultra-highly sensitive magnetic field sensor, is limited by the performance of the probe laser system. The probe laser pumping effect (PLPE) hinders the increase in the performance of probe laser system. Methods: This study investigated the PLPE and proposed a method for suppressing the same. Through changes to the angle of a quarter wave plate and the addition of a triangular modulated magnetic field to the alkali atoms, the suppression point was determined. Results and discussion: Further, related parameters were measured for different degree of polarizations of the probe laser, which confirmed that the influence of PLPE on the magnetic field was the least at the suppressed point.

DOI
10.3389/fphy.2023.1181399

Related papers

Analysis of effects of magnetic field gradient on atomic spin polarization and relaxation in optically pumped atomic magnetometers

Xiujie Fang, Kai Wei, Yueyang Zhai +6 more

The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

Optics Express•Jan 14, 2022•61 citations

The influence of spin-destruction collisions on the precision of atomic SERF magnetometer

Lijun Liu, Shuming Cheng, Zairong Xi +1 more

High precision measurement of magnetic fields has been of great importance for both fundamental physics and practical applications. Magnetometers based on atomic spin effect provide a new technique for high precision measurement and have been enabled as the most sensitive magnetic sensors at present. However, the atomic spins used as probes to sense the magnetic fields are prone to the decoherence effects. For the atomic spin-exchange relaxation free (SERF) magnetometer which operates with high alkali atoms density in very low magnetic fields, the main relaxation mechanism is the spin-destruction collisions between atoms. In this paper, it is demonstrated by numerical simulations that the precision of the atomic SERF magnetometer is significantly affected by this spin-destruction collisions.

Chinese Control Conference (CCC)•Jul 1, 2014•0 citations

Inverse weak measurement in a SERF magnetometer

Qian Cao, Liang Xu, Ziqian Yue +2 more

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

arXiv:2508.12306•Photonics Research•Oct 27, 2025•5 citations

Suppression Method of AC-Stark Shift in SERF Atomic Magnetometer

Yang Li, Ming Ding, Xuejing Liu +3 more

In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.

IEEE photonics journal•Sep 27, 2018•22 citations

Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises

Xiyuan Chen, Hong Zhang, Sheng Zou

Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.

Sensors•Jun 17, 2016•9 citations

Polarization anisotropy in absorption enhanced modulation transfer spectroscopy and laser locking for Rb D 1 line

Wen-Lei Zhao, Xinxiu Zhou, Wenxiang Xie +2 more

In a spin-exchange relaxation-free (SERF) atomic magnetometer, the pump and probe laser frequencies are tuned to the D 1 transition line of alkali metal atoms to enhance measurement sensitivity. The D 1 line, a non-cycling transition, exhibits a low absorption coefficient. This study theoretically analyzes the influence of different parameters on the absorption coefficient of the D 1 line and proposes a polarization-dependent approach to enhance it. A frequency stabilization method based on modulation transfer spectroscopy (MTS) with an enhanced absorption coefficient is introduced. Compared with the conventional method, optimizing the probe beam’s polarization increases the absorption coefficient, raising the amplitude of the MTS signal. The results show that using a stronger MTS signal for frequency stabilization reduces the laser's frequency noise. Using heterodyne measurement, we characterize the linewidth-narrowing effect of MTS locking and evaluate the frequency stability of the locked laser. The linewidth of each laser is reduced from the free-running 2.2 MHz to 885 kHz after MTS stabilization. The Allan deviation measurements of the beat signal between two locked lasers are 2.6 × 10 −11 / τ . This work provides a stable optical frequency reference for SERF atomic magnetometers and offers potential applications in extracting spatial information from optically pumped atoms.

Optics Express•May 16, 2025•5 citations
Introduction: A spin exchange relaxation free atomic magnetometer, as an ultra-highly sensitive magnetic field sensor, is limited by the performance of the probe laser system. The probe laser pumping effect (PLPE) hinders the increase in the performance of probe laser system. Methods: This study investigated the PLPE and proposed a method for suppressing the same. Through changes to the angle of a quarter wave plate and the addition of a triangular modulated magnetic field to the alkali atoms, the suppression point was determined. Results and discussion: Further, related parameters were measured for different degree of polarizations of the probe laser, which confirmed that the influence of PLPE on the magnetic field was the least at the suppressed point.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
High precision measurement of magnetic fields has been of great importance for both fundamental physics and practical applications. Magnetometers based on atomic spin effect provide a new technique for high precision measurement and have been enabled as the most sensitive magnetic sensors at present. However, the atomic spins used as probes to sense the magnetic fields are prone to the decoherence effects. For the atomic spin-exchange relaxation free (SERF) magnetometer which operates with high alkali atoms density in very low magnetic fields, the main relaxation mechanism is the spin-destruction collisions between atoms. In this paper, it is demonstrated by numerical simulations that the precision of the atomic SERF magnetometer is significantly affected by this spin-destruction collisions.
Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.
In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.
Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.
In a spin-exchange relaxation-free (SERF) atomic magnetometer, the pump and probe laser frequencies are tuned to the D 1 transition line of alkali metal atoms to enhance measurement sensitivity. The D 1 line, a non-cycling transition, exhibits a low absorption coefficient. This study theoretically analyzes the influence of different parameters on the absorption coefficient of the D 1 line and proposes a polarization-dependent approach to enhance it. A frequency stabilization method based on modulation transfer spectroscopy (MTS) with an enhanced absorption coefficient is introduced. Compared with the conventional method, optimizing the probe beam’s polarization increases the absorption coefficient, raising the amplitude of the MTS signal. The results show that using a stronger MTS signal for frequency stabilization reduces the laser's frequency noise. Using heterodyne measurement, we characterize the linewidth-narrowing effect of MTS locking and evaluate the frequency stability of the locked laser. The linewidth of each laser is reduced from the free-running 2.2 MHz to 885 kHz after MTS stabilization. The Allan deviation measurements of the beat signal between two locked lasers are 2.6 × 10 −11 / τ . This work provides a stable optical frequency reference for SERF atomic magnetometers and offers potential applications in extracting spatial information from optically pumped atoms.