PRELIMINARY RESEARCH ON A MOLECULAR BEAM FOR THE 1-10 ev RANGE

George T. Skinner, Charles E. Treanor

Published Dec 1, 1959• 0 citations
OpenAlex

Abstract

The design and construction of a molecular-beam apparatus for the production of atomic and molecular beams in the 1 to 10 ev energy range are discussed. A shock tube is used as the source of high-temperature, high-pressure gas, and a hypersonic expansion is used to obtain a high-energy, nearly mono- energetic beam. Use of a two-center potential for the treatment of atom-molecule collisions is discussed. (auth)

Related papers

Intense atomic and molecular beams via neon buffer-gas cooling

David Patterson, Julia Rasmussen, John M. Doyle

We realize a continuous, intense, cold molecular and atomic beam source based on buffer-gas cooling. Hot vapor (up to 600 K) from an oven is mixed with cold (15 K) neon buffer gas, and then emitted into a high-flux beam. The novel use of cold neon as a buffer gas produces a forward velocity distribution and low-energy tail that is comparable to much colder helium-based sources. We expect this source to be trivially generalizable to a very wide range of atomic and molecular species with significant vapor pressure below 1000 K. The source has properties that make it a good starting point for laser cooling of molecules or atoms, cold collision studies, trapping, or nonlinear optics in buffer-gas-cooled atomic or molecular gases. A continuous guided beam of cold deuterated ammonia with a flux of 3 × 10 11 ND 3 molecules s −1 and a continuous free-space beam of cold potassium with a flux of 1 × 10 16 K atoms s −1 are realized.

arXiv:0812.2212•New Journal of Physics•May 14, 2009•82 citations

’’Hot,’’metastable atom, molecular beam source

E. L. Leasure, Charles R. Mueller, Thomas Y. Ridley

A molecular beam source for high-energy metastable atoms, utilizing a corona discharge, is described. It was designed for scattering experiments where accurate alignment of beam components is required. The metastable atoms produced in this source have kinetic energies from 5 to 74 eV dependent on the species and sufficient velocity selection to reveal structure in the differential cross sections. These high-energy metastables were previously reported as photons. When the molecular beam source was operated at 200–300 Torr, a supersonic beam of metastables was produced. An optimization of operating conditions produced a supersonic beam flux two orders of magnitude greater than previously reported.

Review of Scientific Instruments•May 1, 1975•30 citations

THE SIGNIFICANCE OF COMPRESSION SHOCKS IN THE PRODUCTION OF INTENSE MOLECULAR BEAMS WITH NOZZLES

K. Bier, O. F. Hagena

S>In the production of intensive molecular beams using nozzles, compression shocks must be avoided as much as possible since they cause a broadening of the velocity distribution and a reduction of the particle current density of the molecular beam. The conditions for the occurrence and the effect of such compression shocks was investigated by measurement of the velocity distribution and the beam intensity for the case when a convergent nozzle is used for the beam production. It was shown that under given conditions a strong compression shock connected with the collision system of the freely expanding gas beam occurs. This compression reduces the beam intensity in single-molecule beams by an order of magnitude and in condensed beams by two orders of magnitude. When this strong compression shock released from the first beam stop is avoided by a suitable selection of the research conditions, weak compression shocks emanating from the peeler can still occur. Possible reduction of this weak compression shock is discussed. (tr-auth)

•Nov 1, 1962•0 citations

A versatile molecular beam apparatus for cold/ultracold collisions

Chandika Amarasinghe, Chatura A. Perera, Arthur G. Suits

We have developed an apparatus capable of performing intrabeam and near-copropagating beam scattering experiments at collision energies from room temperature to below 1 K where interesting quantum phenomena can be observed. A detailed description of the major components of the apparatus, single and dual molecular beam valves, high speed chopper, and the discharge source, is presented. With the intrabeam scattering setup, a novel dual-slit chopper permits collision energies down to millikelvins with a collision energy spread of 20%. With the near-copropagating beam configuration, state-to-state differential cross sections for rotationally inelastic collisions of highly vibrationally excited NO molecules with Ar have been measured at broadly tunable energies documenting the versatility of the instrument. Future applications in stereodynamics and cold state-to-state collisions of vibrationally excited polyatomic molecules are briefly discussed.

The Journal of Chemical Physics•May 12, 2020•13 citations

A general cold atomic and molecular beam source

Stephen Maxwell, Nathaniel Brahms, Robert deCarvalho +5 more

We demonstrate and characterize a high-flux beam source for cold, slow atoms or molecules. The desired species is vaporized using laser ablation, then cooled by thermalization in a cryogenic cell of buffer gas. The beam is formed by particles exiting a hole in the buffer gas cell. We characterize the properties of the beam (flux, forward velocity, temperature) for both an atom (Na) and a molecule (PbO) under varying buffer gas density, and discuss conditions for optimizing these beam parameters. Our source compares favorably to existing techniques of beam formation, for a variety of applications.

Bulletin of the American Physical Society•May 20, 2005•0 citations

Note: High density pulsed molecular beam for cold ion chemistry

Mark Kokish, Vaishnavi Rajagopal, Joan P. Marler +1 more

A recent expansion of cold and ultracold molecule applications has led to renewed focus on molecular species preparation under ultrahigh vacuum conditions. Meanwhile, molecular beams have been used to study gas phase chemical reactions for decades. In this paper, we describe an apparatus that uses pulsed molecular beam technology to achieve high local gas densities, leading to faster reaction rates with cold trapped ions. We characterize the beam's spatial profile using the trapped ions themselves. This apparatus could be used for preparation of molecular species by reactions requiring excitation of trapped ion precursors to states with short lifetimes or for obtaining a high reaction rate with minimal increase of background chamber pressure.

arXiv:1406.5784•Review of Scientific Instruments•Aug 1, 2014•5 citations
The design and construction of a molecular-beam apparatus for the production of atomic and molecular beams in the 1 to 10 ev energy range are discussed. A shock tube is used as the source of high-temperature, high-pressure gas, and a hypersonic expansion is used to obtain a high-energy, nearly mono- energetic beam. Use of a two-center potential for the treatment of atom-molecule collisions is discussed. (auth)
We realize a continuous, intense, cold molecular and atomic beam source based on buffer-gas cooling. Hot vapor (up to 600 K) from an oven is mixed with cold (15 K) neon buffer gas, and then emitted into a high-flux beam. The novel use of cold neon as a buffer gas produces a forward velocity distribution and low-energy tail that is comparable to much colder helium-based sources. We expect this source to be trivially generalizable to a very wide range of atomic and molecular species with significant vapor pressure below 1000 K. The source has properties that make it a good starting point for laser cooling of molecules or atoms, cold collision studies, trapping, or nonlinear optics in buffer-gas-cooled atomic or molecular gases. A continuous guided beam of cold deuterated ammonia with a flux of 3 × 10 11 ND 3 molecules s −1 and a continuous free-space beam of cold potassium with a flux of 1 × 10 16 K atoms s −1 are realized.
A molecular beam source for high-energy metastable atoms, utilizing a corona discharge, is described. It was designed for scattering experiments where accurate alignment of beam components is required. The metastable atoms produced in this source have kinetic energies from 5 to 74 eV dependent on the species and sufficient velocity selection to reveal structure in the differential cross sections. These high-energy metastables were previously reported as photons. When the molecular beam source was operated at 200–300 Torr, a supersonic beam of metastables was produced. An optimization of operating conditions produced a supersonic beam flux two orders of magnitude greater than previously reported.
S>In the production of intensive molecular beams using nozzles, compression shocks must be avoided as much as possible since they cause a broadening of the velocity distribution and a reduction of the particle current density of the molecular beam. The conditions for the occurrence and the effect of such compression shocks was investigated by measurement of the velocity distribution and the beam intensity for the case when a convergent nozzle is used for the beam production. It was shown that under given conditions a strong compression shock connected with the collision system of the freely expanding gas beam occurs. This compression reduces the beam intensity in single-molecule beams by an order of magnitude and in condensed beams by two orders of magnitude. When this strong compression shock released from the first beam stop is avoided by a suitable selection of the research conditions, weak compression shocks emanating from the peeler can still occur. Possible reduction of this weak compression shock is discussed. (tr-auth)
We have developed an apparatus capable of performing intrabeam and near-copropagating beam scattering experiments at collision energies from room temperature to below 1 K where interesting quantum phenomena can be observed. A detailed description of the major components of the apparatus, single and dual molecular beam valves, high speed chopper, and the discharge source, is presented. With the intrabeam scattering setup, a novel dual-slit chopper permits collision energies down to millikelvins with a collision energy spread of 20%. With the near-copropagating beam configuration, state-to-state differential cross sections for rotationally inelastic collisions of highly vibrationally excited NO molecules with Ar have been measured at broadly tunable energies documenting the versatility of the instrument. Future applications in stereodynamics and cold state-to-state collisions of vibrationally excited polyatomic molecules are briefly discussed.
We demonstrate and characterize a high-flux beam source for cold, slow atoms or molecules. The desired species is vaporized using laser ablation, then cooled by thermalization in a cryogenic cell of buffer gas. The beam is formed by particles exiting a hole in the buffer gas cell. We characterize the properties of the beam (flux, forward velocity, temperature) for both an atom (Na) and a molecule (PbO) under varying buffer gas density, and discuss conditions for optimizing these beam parameters. Our source compares favorably to existing techniques of beam formation, for a variety of applications.
A recent expansion of cold and ultracold molecule applications has led to renewed focus on molecular species preparation under ultrahigh vacuum conditions. Meanwhile, molecular beams have been used to study gas phase chemical reactions for decades. In this paper, we describe an apparatus that uses pulsed molecular beam technology to achieve high local gas densities, leading to faster reaction rates with cold trapped ions. We characterize the beam's spatial profile using the trapped ions themselves. This apparatus could be used for preparation of molecular species by reactions requiring excitation of trapped ion precursors to states with short lifetimes or for obtaining a high reaction rate with minimal increase of background chamber pressure.