Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Phase sensitivity enhancement for the SU(1,1) interferometer using photon level operations

Jun Xin

Published Nov 30, 2021• 25 citations
Publisher

Abstract

We propose to employ photon level operations (PLOs) to enhance the phase sensitivity of the SU(1,1) interferometer (SUI). Two types of PLOs are considered, including photon subtraction scheme (PSS) and photon addition scheme (PAS). By performing either PSS or PAS on the two arms inside the SUI, we demonstrate that the phase sensitivity of the SUI can be enhanced. More interestingly, we find that both PSS and PAS are able to increase the robustness of the SUI against the internal loss of the interferometer, which is one of the main imperfect factors that limit the performance of the SUI.

DOI
10.1364/oe.444608

Related papers

Phase sensitivity of an SU(1,1) interferometer in photon-loss via photon operations

Youke Xu, Teng Zhao, Qingqian Kang +3 more

We study the phase sensitivity of an SU(1,1) interferometer with photon loss by using three different photon operations schemes, i.e., performing photon-addition operation on the input port of the SU(1,1) interferometer (Scheme A), the interior of SU(1,1) interferometer (Scheme B), and both of them (Scheme C). We compare the performance of the three schemes in phase estimation by performing the same times of photon-addition operation to the mode b. The results show that Scheme B improves the phase sensitivity best in ideal case, and Scheme C performs well against internal loss, especially in the case of strong loss. All the three schemes can beat the standard quantum limit in the presence of photon loss, but Scheme B and Scheme C can break through the standard quantum limit in a larger loss range.

Optics Express•Feb 8, 2023•23 citations

Phase estimation via multi-photon subtraction inside the SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Youke Xu +3 more

Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.

arXiv:2311.14612•Physica Scripta•Jul 4, 2024•9 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

arXiv:2410.17612•Optics Express•Apr 14, 2025•8 citations

Phase estimation of an SU(1,1) interferometer with a coherent superposition squeezed vacuum in a realistic case

Youke Xu, Shoukang Chang, Cunjin Liu +2 more

The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.

Optics Express•Sep 22, 2022•11 citations

Improved phase sensitivity of an SU(1,1) interferometer based on the internal single-path local squeezing operation

Qingqian Kang, Zekun Zhao, Teng Zhao +2 more

Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.

arXiv:2410.21292•Frontiers of Physics•Jan 1, 2025•4 citations

Enhancing the precision of a phase measurement through phase-sensitive non-Gaussianity

Kun Zhang, Yinghui Lv, Yu Guo +2 more

Encoding is an indispensable procedure in general phase measurement, and it is usually performed with a deterministic unitary transformation between the initial probe state and the final state. In order to improve the measurement precision, many studies focus on the optimization of the initial probe state. In this paper, we propose a scheme of subtracting one photon from the output state of an SU(1,1) interferometer. In addition to improving the output state, we find that this scheme can be used to optimize the encoding procedure. The performance of this type of optimization is only strong when the phase-sensitive negativity is induced in the Wigner function of the equivalent probe state. If a nearly perfect single-photon detector is used for the single-photon subtraction operation, the phase sensitivity within a narrow phase range can surpass $1/(\sqrt{\ensuremath{\nu}}N)$, where $N$ is the mean number of photons inside the SU(1,1) interferometer, and $\ensuremath{\nu}$ is the number of copies of the Gaussian probe state.

Physical Review A•Apr 13, 2022•10 citations
We propose to employ photon level operations (PLOs) to enhance the phase sensitivity of the SU(1,1) interferometer (SUI). Two types of PLOs are considered, including photon subtraction scheme (PSS) and photon addition scheme (PAS). By performing either PSS or PAS on the two arms inside the SUI, we demonstrate that the phase sensitivity of the SUI can be enhanced. More interestingly, we find that both PSS and PAS are able to increase the robustness of the SUI against the internal loss of the interferometer, which is one of the main imperfect factors that limit the performance of the SUI.
We study the phase sensitivity of an SU(1,1) interferometer with photon loss by using three different photon operations schemes, i.e., performing photon-addition operation on the input port of the SU(1,1) interferometer (Scheme A), the interior of SU(1,1) interferometer (Scheme B), and both of them (Scheme C). We compare the performance of the three schemes in phase estimation by performing the same times of photon-addition operation to the mode b. The results show that Scheme B improves the phase sensitivity best in ideal case, and Scheme C performs well against internal loss, especially in the case of strong loss. All the three schemes can beat the standard quantum limit in the presence of photon loss, but Scheme B and Scheme C can break through the standard quantum limit in a larger loss range.
Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.
Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.
Encoding is an indispensable procedure in general phase measurement, and it is usually performed with a deterministic unitary transformation between the initial probe state and the final state. In order to improve the measurement precision, many studies focus on the optimization of the initial probe state. In this paper, we propose a scheme of subtracting one photon from the output state of an SU(1,1) interferometer. In addition to improving the output state, we find that this scheme can be used to optimize the encoding procedure. The performance of this type of optimization is only strong when the phase-sensitive negativity is induced in the Wigner function of the equivalent probe state. If a nearly perfect single-photon detector is used for the single-photon subtraction operation, the phase sensitivity within a narrow phase range can surpass $1/(\sqrt{\ensuremath{\nu}}N)$, where NNN is the mean number of photons inside the SU(1,1) interferometer, and $\ensuremath{\nu}$ is the number of copies of the Gaussian probe state.