Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2311.14612 · Physica Scripta

Phase estimation via multi-photon subtraction inside the SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Youke Xu, Teng Zhao, Cunjin Liu, Liyun Hu

Published Jul 4, 2024• 9 citations
arXivHTMLPDF

Abstract

Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.

DOI
10.1088/1402-4896/ad5f68

Related papers

Phase estimation via a number-conserving operation inside a SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Teng Zhao +2 more

Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing a number-conserving operation (NCO), i.e., $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ and ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$, inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of the NCO on the phase sensitivity, the quantum Fisher information (QFI), and the quantum Cram\'er-Rao bound under both ideal and photon-loss scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the QFI and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme exhibits superior improvement in both the ideal and photon-loss cases in terms of phase sensitivity. Moreover, in the ideal case, the $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ scheme slightly outperforms the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme in terms of the QFI. However, in the presence of high photon losses, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme demonstrates a greater advantage.

arXiv:2406.06528•Physical Review A•Aug 23, 2024•13 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

arXiv:2410.17612•Optics Express•Apr 14, 2025•8 citations

Enhancing Phase Estimation in a Hybrid Interferometer via Kerr Nonlinearity and Photon Subtraction

Lifen Guo, Qingqian Kang, Zekun Zhao +5 more

We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling ($1/N$), and approach the super-Heisenberg scaling ($1/N^{2}$)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ $1/N^{2}$ is the ultimate precision limit permitted by the $k=2$ Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.

quant-pharXiv:2605.20893•May 21, 2026•0 citations

Improved phase sensitivity of an SU(1,1) interferometer based on the internal single-path local squeezing operation

Qingqian Kang, Zekun Zhao, Teng Zhao +2 more

Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.

arXiv:2410.21292•Frontiers of Physics•Jan 1, 2025•4 citations

Optimization of the phase sensitivity through photon-subtraction inside the Mach-Zehnder interferometer

Qisi Zhou, Qingqian Kang, Teng Zhao +3 more

Abstract We propose a photon subtraction scheme within the Mach–Zehnder interferometer using a coherent state and a squeezed vacuum state as inputs. By systematically comparing intensity detection and homodyne detection methods, we demonstrate that strategically applied photon subtraction ( a -mode subtraction) significantly enhances the phase sensitivity of all detection methods. Under this configuration, homodyne detection achieves superior phase sensitivity and loss robustness compared to intensity detection. Remarkably, under 30% photon loss, the system surpasses the Heisenberg limit, enabled by the synergy among the squeezed vacuum state, non-Gaussian operations, and detection optimization. Furthermore, we quantify performance through the quantum Fisher information and the quantum Cramér-Rao bound analyses under both ideal and lossy conditions.

arXiv:2505.04499•Journal of Physics B Atomic Molecular and Optical Physics•Apr 22, 2026•3 citations

Phase estimation of an SU(1,1) interferometer with a coherent superposition squeezed vacuum in a realistic case

Youke Xu, Shoukang Chang, Cunjin Liu +2 more

The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.

Optics Express•Sep 22, 2022•11 citations
Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing a number-conserving operation (NCO), i.e., $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ and ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$, inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of the NCO on the phase sensitivity, the quantum Fisher information (QFI), and the quantum Cram\'er-Rao bound under both ideal and photon-loss scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the QFI and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme exhibits superior improvement in both the ideal and photon-loss cases in terms of phase sensitivity. Moreover, in the ideal case, the $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ scheme slightly outperforms the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme in terms of the QFI. However, in the presence of high photon losses, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme demonstrates a greater advantage.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling (1/N1/N1/N), and approach the super-Heisenberg scaling (1/N21/N^{2}1/N2)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ 1/N21/N^{2}1/N2 is the ultimate precision limit permitted by the k=2k=2k=2 Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.
Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.
Abstract We propose a photon subtraction scheme within the Mach–Zehnder interferometer using a coherent state and a squeezed vacuum state as inputs. By systematically comparing intensity detection and homodyne detection methods, we demonstrate that strategically applied photon subtraction ( a -mode subtraction) significantly enhances the phase sensitivity of all detection methods. Under this configuration, homodyne detection achieves superior phase sensitivity and loss robustness compared to intensity detection. Remarkably, under 30% photon loss, the system surpasses the Heisenberg limit, enabled by the synergy among the squeezed vacuum state, non-Gaussian operations, and detection optimization. Furthermore, we quantify performance through the quantum Fisher information and the quantum Cramér-Rao bound analyses under both ideal and lossy conditions.
The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.