The influence of the anisotropic Zeeman effect on optical decoherence was studied for the $1.54\text{ }\ensuremath{\mu}\text{m}$ telecom transition in
Er3+:Y2SiO5 using photon echo spectroscopy as a function of applied magnetic field orientation and strength. The decoherence strongly correlates with the Zeeman energy splittings described by the ground- and excited-state
g factor variations for all inequivalent
Er3+ sites, with the observed decoherence times arising from the combined effects of the magnetic dipole-dipole coupling strength and the ground- and excited-state spin-flip rates, along with the natural lifetime of the upper level. The decoherence time was maximized along a preferred magnetic field orientation that minimized the effects of spectral diffusion and that enabled the measurement of an exceptionally narrow optical resonance in a solid---demonstrating a homogeneous linewidth as narrow as 73 Hz.
Recently we have reported[1] on the measurements of electronic dephasing (T_2) and radiationless decay (T_1) in molecules using emission spectroscopy as a probe for the detection of the photon echo. This right-angle photon echo utilizes a single mode of a narrow-band (~MHz) cw dye laser and an intracavity electro-optical (EO) element that modulates the frequency of the laser.[2] Applying voltage pulses into the EO crystal switches the laser frequency from ω_0 (the peak frequency of the transition resonance) into another frequency ω. This switching procedure introduced by Brewer et al. for the observation of transients in the forward direction of the laser allows one to observe coherent transients in gases,[1,2] solids[3-5] and molecular beams.[6] Typically, the dispersion of the nonlinear EO crystal (e.g., AD*P) gives a 60 MHz frequency shift within the inhomogeneous resonance of the optical transition (width ~GHz or larger). Therefore, to switch the laser frequency further, one must use high-voltage signals that are usually hard to obtain especially for multiple-pulse experiments. Secondly, there is a limit on the frequency shift which is conditioned by the mode spacing of the cavity. Thirdly, because the laser is switched into a new group of molecules some complications may arise in interpreting the transient spectra especially in large molecules. This is because in large molecules the density of excited states is high and thus the buildup of transients of w molecules (which could be complex) will be superimposed on the decay of ω_0 molecules. Finally, off-resonance effects (e.g., beats) between the molecules at frequency ω and ω_0 cannot be avoided.