We present operation of a photonically integrated wavelength reference at 780 nm using a dual beam geometry. The dual beams are generated by a pair of extreme mode converting grating beam expanders that generate a pair of overlapped, counter-propagating beams inside the volume of a microfabricated vapor cell. We perform spectroscopy of rubidium and a characterize the stability of laser locked to a sub-Doppler transition at 780 nm. By stabilizing the laser to a known transition in an atomic vapor, this device can serve as a quantum wavelength reference. The dual beam geometry also enables investigation of two-photon absorption in a three-level ladder configuration in rubidium using excitation at 780 nm + 776 nm.
We present operation of a photonically integrated wavelength reference at 780 nm using a dual beam geometry. The dual beams are generated by a pair of extreme mode converting grating beam expanders that generate a pair of overlapped, counter-propagating beams inside the volume of a microfabricated vapor cell. We perform spectroscopy of rubidium and a characterize the stability of laser locked to a sub-Doppler transition at 780 nm. By stabilizing the laser to a known transition in an atomic vapor, this device can serve as a quantum wavelength reference. The dual beam geometry also enables investigation of two-photon absorption in a three-level ladder configuration in rubidium using excitation at 780 nm + 776 nm.
Wavelength references in the telecom spectrum have applications in communications and dimensional metrology. However, they typically consist of bulk optics and vapor cells. Photonic integration of these components may lead to low cost, portable devices. Here we demonstrate the incorporation of a photonic Rb spectrometer with an AlN microresonator frequency doubler. Light at 1560 nm is coupled onto a chip containing the AlN microresonator frequency doubler. The resulting 780 nm light is sent to the photonic Rb spectrometer, which consists of an apodized grating beam expander and microfabricated MEMS vapor cell. We perform Doppler broadened spectroscopy of the D2 line and demonstrate preliminary laser stabilization to these features.
Devices based on spectroscopy of atomic vapors can measure physical quantities such as magnetic fields, RF electric fields, time and length, and rotation and have applications in a broad range of fields including communications, medicine, and navigation. We present a type of photonic device that interfaces single-mode silicon nitride optical waveguides with warm atomic vapors, enabling precision spectroscopy in an extremely compact (<1 cm3) package. We perform precision spectroscopy of rubidium confined in a micro-machined, 27 mm3 volume, vapor cell using a collimated free-space 120 μm diameter laser beam derived directly from a single-mode silicon nitride waveguide. With this optical-fiber integrated photonic spectrometer, we demonstrate an optical frequency reference at 780 nm with a stability of 10−11 from 1 to 104 s. This device harnesses the benefits of both photonic integration and precision spectroscopy for the next generation of quantum sensors and devices based on atomic vapors.
We demonstrate a dual-wavelength optical frequency standard based on the dual-optical-transition modulation transfer spectroscopy (DOT-MTS) between different quantum transitions of the rubidium D1 (795 nm) and D2 (780 nm) lines. In a single rubidium atomic ensemble, modulation frequency sidebands from the 780 nm pump beam are simultaneously transferred to both the 780 and 795 nm probe lasers. The DOT-MTS enables the simultaneous stabilization of 780 and 795 nm lasers on a single vapor cell. Both lasers exhibit a frequency instability in the low 10 −14 range at 1 s of averaging, as estimated from the residual error signal. A theoretical model is developed based on the V-type atomic level structure to illustrate the dual-wavelength spectroscopy. This approach can be extended to develop a multi-wavelength optical frequency standard within a single atomic ensemble, broadening its applicability in fields such as precision metrology, Rydberg atoms, wavelength standards, optical networks, and beyond.
Many of modern quantum technologies require the development of high-performance and low-power consumption miniaturized devices such as laser systems, atomic clocks, magnetometers and other quantum sensors. These instruments are to date often based on the use of chip-size diode lasers and microfabricated (MEMS) cells filled with alkali atoms [1]. An interesting challenge concerns the development of miniaturized optical frequency references (OFR). Different approaches have been engaged in this direction. One of the most successful example is a rubidium microcell-based OFR, involving the two-photon spectroscopy technique. This approach has recently demonstrated a remarkable frequency stability level of 4.4×10–12 at 1 s [2]. The present study is focused on a simple alternative approach based on sub-Doppler spectroscopy (SDS) with counter-propagating light beams. We propose to use dual-frequency light beams with orthogonal linear polarizations and frequency difference w1–w2 = Dhfs, with Dhfs the frequency of the atom ground-state hyper-fine splitting. First dual-frequency sub-Doppler spectroscopy (DF SDS) experiments have been performed with cmscale cells [3,4]. In the present study, we present preliminary spectroscopy and frequency stability results of alaser stabilized using DF SDS with a Cs vapor microfabricated cell [5] (Fig.1a). An extended-cavity diode laser (ECDL) source and a Mach-Zehnder intensity EOM are used to obtain the dual-frequency light field. A forward beam goes through the cell and is then reflected by a mirror to create the backward beam.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
Optical wavelength standards, based on the optical transitions of atoms or molecules, provide ultra-high precision frequency references and are the core technology of next-generation optical clocks. Their stability far exceeds that of the microwave frequency range, laying the foundation for precision metrology and cutting-edge scientific research. The wavelength standard device based on the 5S1/2-5D3/2 hyperfine level two-photon transition of 87Rb atoms exhibits significant advantages such as no Doppler broadening, high signal-to-noise ratio (SNR), and potential for miniaturization and chip integration, showing important application potential in precision measurement fields like rubidium atomic clocks and optical communication. In this paper, an experimental setup for two-photon transition was constructed using an external cavity diode laser (ECDL), achieving stable locking of the 778 nm wavelength by modulating the laser current. The effects of the temperature and length of the atomic vapor cell on the blue fluorescence linewidth, SNR, and frequency stability were systematically studied, further optimizing the system. By using an atomic vapor cell designed at Brewster's angle, optical reflection loss was effectively reduced, compensating for the impact of shortened optical path on frequency stability in miniaturized atomic vapor cells. This provides new research directions and performance enhancement solutions for the miniaturization and chip integration of two-photon transition systems. In the improved system, a Brewster-angle glass vapor cell with a length of 30 mm was used and heated to 110°C, achieving a linewidth of 1.69 MHz full width at half maximum (FWHM) and a SNR of 20 dB. The system demonstrated a instability of 9.86×10-11 over a 1-second averaging time and a minimum instability of 5.79×10-11 over a 5.7-second averaging time. This achievement provides key technological support for the practical application of the next generation of miniaturized optical atomic clocks, with the potential for widespread use in portable metrology equipment and space science through integrated design and noise suppression optimization in the future.