Chinese Optics Letters

Uncertainty evaluation of the second-order Zeeman shift of a transportable 87Rb atomic fountain clock

He-Nan Cheng, Siminda Deng, Zhen Zhang, Jingfeng Xiang, Jingwei Ji, Wei Ren, Tang Li, Qiuzhi Qu, Liang Liu, Desheng Lü

Published Jan 1, 2021• 7 citations
Publisher

Abstract

In this article, taking advantage of the special magnetic shieldings and the optimal coil design of a transportable Rb atomic fountain clock, the intensity distribution in space and the fluctuations with time of the quantization magnetic field in the Ramsey region were measured using the atomic magneton-sensitive transition method. In an approximately 310 mm long Ramsey region, a peak-to-peak magnetic field intensity of a 0.74 nT deviation in space and a 0.06 nT fluctuation with time were obtained. These results correspond to a second-order Zeeman frequency shift of approximately (2095.5±5.1)×10-17. This is an essential step in advancing the total frequency uncertainty of the fountain clock to the order of 10-17.

DOI
10.3788/col202119.120201

Related papers

87Rb喷泉原子钟的磁场测量

Chunyan Shi, Rong Wei, Zichao Zhou +3 more

An experiment on measuring the magnetic field in Ramsey interaction region of the atomic fountain clock by detecting the Zeeman frequency shift of 87 Rb hyperfine transition is presented.By mu-metal shielding and coils compensating, the magnetic fluctuations resulting from asymmetry and instability are less than 10 and 0.025 nT, respectively.The relative frequency uncertainty of atomic fountain clock caused by the magnetic field is less than 5.4×10 -16 .

Chinese Optics Letters•Jan 1, 2010•16 citations

Measurement of a Weak Magnetic Field Using Cold Atoms

Takayuki Kurosu, Yasuhiro Fukuyama, Kentaro Abe +1 more

Laser-cooled atoms were utilized to precisely measure a weak magnetic field. The technique is based on the linear Zeeman shift of the hyperfine transition of cesium atom and allows high-resolution measurement in the presence of a field gradient. The method was applied to evaluate the C-field of an atomic fountain frequency standard, in which a field-sensitive transition was probed by Ramsey resonance. The relationship between the measurement time and the resolution is also discussed.

Japanese Journal of Applied Physics•May 15, 2002•4 citations

Magnetic field measurement by stimulated Raman transitions and smoothing by dynamical compensation in rubidium fountain clock

Wenli Wang, Richang Dong, Rong Wei +3 more

We present a method for magnetic field measurement by the weak magnetic-sensitive Zeeman splitting and a method for measuring the magnetic field vector by probing the line strength of stimulated Raman transitions. Compared with the traditional measurement, the contrast of the weak magnetic-sensitive resonance signal is improved significantly for gradient field. We also present a dynamical compensation method to smooth the spatial fluctuation of the magnetic field in the fountain clock. A homogeneous field with a 0.4 nT peak-to-peak value is realized compared to 5nT under the static magnetic field.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Dephasing in sodium Ramsey interferometry under a weak inhomogeneous magnetic field

Keisuke Nakamura, Motoyuki Murakami, Atsuo Morinaga

Abstract In Ramsey interference of the clock transition of cold sodium atoms, we observed dephasing of the visibility, which was based on the frequency fluctuation due to the second-order Zeeman effect for inhomogeneity of the magnetic field within the atomic cloud. The frequency fluctuation was enhanced with increased strength of the quantization magnetic field, causing the dephasing of the visibility to become large. The theoretical dephasing function with frequency fluctuation was in good agreement with experimental values.

Journal of Physics B Atomic Molecular and Optical Physics•Mar 17, 2015•1 citation

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•28 citations

Clock with 8 × 10 − 19 Systematic Uncertainty

Alexander Aeppli, Kyungtae Kim, William Warfield +2 more

We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.

arXiv:2403.10664•Physical Review Letters•Jul 10, 2024•246 citations
In this article, taking advantage of the special magnetic shieldings and the optimal coil design of a transportable Rb atomic fountain clock, the intensity distribution in space and the fluctuations with time of the quantization magnetic field in the Ramsey region were measured using the atomic magneton-sensitive transition method. In an approximately 310 mm long Ramsey region, a peak-to-peak magnetic field intensity of a 0.74 nT deviation in space and a 0.06 nT fluctuation with time were obtained. These results correspond to a second-order Zeeman frequency shift of approximately (2095.5±5.1)×10-17. This is an essential step in advancing the total frequency uncertainty of the fountain clock to the order of 10-17.
We present a method for magnetic field measurement by the weak magnetic-sensitive Zeeman splitting and a method for measuring the magnetic field vector by probing the line strength of stimulated Raman transitions. Compared with the traditional measurement, the contrast of the weak magnetic-sensitive resonance signal is improved significantly for gradient field. We also present a dynamical compensation method to smooth the spatial fluctuation of the magnetic field in the fountain clock. A homogeneous field with a 0.4 nT peak-to-peak value is realized compared to 5nT under the static magnetic field.
Abstract In Ramsey interference of the clock transition of cold sodium atoms, we observed dephasing of the visibility, which was based on the frequency fluctuation due to the second-order Zeeman effect for inhomogeneity of the magnetic field within the atomic cloud. The frequency fluctuation was enhanced with increased strength of the quantization magnetic field, causing the dephasing of the visibility to become large. The theoretical dephasing function with frequency fluctuation was in good agreement with experimental values.
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.