Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Demonstrating the 6 K measurement capability of an improved scanning quantum cryogenic atom microscope

Stephen Taylor, Fan Yang, Brandon Freudenstein, Benjamin Lev

Published Jun 4, 2021• 0 citations
OpenAlex

Related papers

A Scanning Quantum Cryogenic Atom Microscope

Benjamin Lev

Bulletin of the American Physical Society•Mar 15, 2017•0 citations

A cryogenic quantum gas scanning magnetic microscope

Richard Turner, Matthew Naides, Ruby A. Lai +2 more

Bulletin of the American Physical Society•Mar 3, 2014•0 citations

The SQCRAMscope: Scanning Quantum CRyogenic Atom Microscope

Richard Turner, Jack DiSciacca, Shenglan Qiao +1 more

Bulletin of the American Physical Society•Mar 5, 2015•0 citations

A Single Atom Scanning Microscope for Cavity Field Detection

Yuehui Lu

Bulletin of the American Physical Society•Jun 3, 2021•0 citations

Sensing Magnetic Fields with a Giant Quantum Wave

József Fortágh, Andreas Günther

Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials.However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers.We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution.The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating.The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μm) or 6 nT= ffiffiffiffiffiffi Hz p per point at its duty cycle.Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT= ffiffiffiffiffiffi Hz p for each point during the same time as a point-by-point scanner measures these points sequentially.Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10 -6 Φ 0 = ffiffiffiffiffiffi Hz p ) over previous atomic probe magnetometers capable of scanning near samples.These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged.We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

Physics•Mar 27, 2017•0 citations

A scanning quantum cryogenic atom microscope at 6 K

Stephen Taylor, Fan Yang, Brandon A. Freudenstein +1 more

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.

arXiv:2010.03559•SciPost Physics•Mar 9, 2021•4 citations
Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials.However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers.We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution.The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating.The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μm) or 6 nT= ffiffiffiffiffiffi Hz p per point at its duty cycle.Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT= ffiffiffiffiffiffi Hz p for each point during the same time as a point-by-point scanner measures these points sequentially.Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10 -6 Φ 0 = ffiffiffiffiffiffi Hz p ) over previous atomic probe magnetometers capable of scanning near samples.These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged.We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.
The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.