Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The design and instrumentation of a superconducting bolometer

Jerald Ray Hyde

Published Jan 1, 2015• 0 citations
Publisher
DOI
10.25549/usctheses-c38-337314

Related papers

Design and optimization of a YBCO based superconducting bolometer

Andrea Napolitano

•Jul 27, 2022•0 citations

Design of a superconducting bolometer for low-power standards in the millimetre wave field

Domenico Andreone, L. Brunetti, M. Petrizzelli

Sensors and Actuators A Physical•Apr 1, 1994•2 citations

Fast-response superconducting electronic bolometer

Eugene M. Gershenzon, Murray Gershenzon, Gregory N Gol'tsman +2 more

Technical Physics Letters•Feb 1, 1989•0 citations

Superconducting multiplexer for arrays of transition edge sensors

James A. Chervenak, K. D. Irwin, Erich N. Grossman +3 more

We report the design and testing of an analog superconducting time-division multiplexer to instrument large format arrays of low-temperature bolometers and microcalorimeters. The circuit is designed to multiplex an array of superconducting quantum interference devices, thereby simplifying wiring and room temperature electronics. We have fabricated a prototype 8×1 multiplexer chip and show a switching rate of 1 MHz. We calculate that a 32×32 array or larger is feasible.

Applied Physics Letters•Jun 28, 1999•285 citations

A 1.4-THz Superconducting HEB Mixer for DATE5

W. Zhang, Wei Miao, Kang Zhang +1 more

Purple Mountain Observatory as well as its collaborators is proposing to build a 5-m THz telescope (DATE5) at Dome A, Antarctic. Two THz heterodyne receivers, with one at 1.4 THz, are being considered as its first generation instrument. Here we report on the development of a 1.4-THz superconducting hot-electron bolometer (HEB) mixer for DATE5, which adopts a twin-slot antenna design. The direct-detection spectral (FTS) response of the 1.4-THz superconducting HEB mixer, with the HEB device fabricated at MSPU, has been measured, giving a frequency coverage of 0.8~1.5THz. And the measured FTS response appears in good agreement with the simulated one. Preliminary noise- temperature measurement at a lower frequency of 0.85 THz shows a receiver noise temperature of 1500 K. The estimated performance at 1.4 THz should be less than 1000 K in terms of the measured FTS response. Detailed simulation and experimental results will be presented.

•Jan 1, 2012•1 citation

Time-domain multiplexed SQUID readout of a bolometer camera for APEX

V. Zakosarenko, Marco Schulz, Alan B. Krueger +9 more

We describe the development and fabrication of the sub-millimeter APEX (Atacama pathfinder experiment) bolometer camera (SABOCA) and its installation at the APEX radio telescope in Chile. SABOCA has 37 bolometers for a wavelength of about 0.35 mm. The bolometers with superconducting transition-edge sensors are read out by superconducting quantum interference devices (SQUIDs). Time-domain multiplexing was used to compress 40 readout signals into four output channels, which are further amplified by superconducting quantum interference filters (SQIF). The multiplexer readout circuit is described in detail. One spare SQUID and two spare bolometers have been used as reference to evaluate contributions to the bolometer noise figure. SABOCA's electrical noise equivalent power is about 7 × 10 − 16 W Hz − 1/2 , whereas the optical noise equivalent flux density measured at APEX is better than 0.35 Jy Hz − 1/2 (1 Jy = 10 − 26 W m − 2 Hz − 1 ). The measured bolometer noise exceeds the theoretical estimation by factor of two, possibly caused by excess noise in the transition-edge sensor. Nevertheless the achieved instrumental sensitivity meets the specification given by the APEX board. SABOCA was commissioned as the facility instrument in the spring of 2009.

Superconductor Science and Technology•Dec 10, 2010•20 citations
Purple Mountain Observatory as well as its collaborators is proposing to build a 5-m THz telescope (DATE5) at Dome A, Antarctic. Two THz heterodyne receivers, with one at 1.4 THz, are being considered as its first generation instrument. Here we report on the development of a 1.4-THz superconducting hot-electron bolometer (HEB) mixer for DATE5, which adopts a twin-slot antenna design. The direct-detection spectral (FTS) response of the 1.4-THz superconducting HEB mixer, with the HEB device fabricated at MSPU, has been measured, giving a frequency coverage of 0.8~1.5THz. And the measured FTS response appears in good agreement with the simulated one. Preliminary noise- temperature measurement at a lower frequency of 0.85 THz shows a receiver noise temperature of 1500 K. The estimated performance at 1.4 THz should be less than 1000 K in terms of the measured FTS response. Detailed simulation and experimental results will be presented.
We describe the development and fabrication of the sub-millimeter APEX (Atacama pathfinder experiment) bolometer camera (SABOCA) and its installation at the APEX radio telescope in Chile. SABOCA has 37 bolometers for a wavelength of about 0.35 mm. The bolometers with superconducting transition-edge sensors are read out by superconducting quantum interference devices (SQUIDs). Time-domain multiplexing was used to compress 40 readout signals into four output channels, which are further amplified by superconducting quantum interference filters (SQIF). The multiplexer readout circuit is described in detail. One spare SQUID and two spare bolometers have been used as reference to evaluate contributions to the bolometer noise figure. SABOCA's electrical noise equivalent power is about 7 × 10 − 16 W Hz − 1/2 , whereas the optical noise equivalent flux density measured at APEX is better than 0.35 Jy Hz − 1/2 (1 Jy = 10 − 26 W m − 2 Hz − 1 ). The measured bolometer noise exceeds the theoretical estimation by factor of two, possibly caused by excess noise in the transition-edge sensor. Nevertheless the achieved instrumental sensitivity meets the specification given by the APEX board. SABOCA was commissioned as the facility instrument in the spring of 2009.