Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors

Chip-Scale Ultra-Low Field Atomic Magnetometer Based on Coherent Population Trapping

Hyun-Gue Hong, Sang Eon Park, Sang-Bum Lee, Myoung-Sun Heo, Jongcheol Park, Tae Hyun Kim, Hee Yeon Kim, Taeg Yong Kwon

Published Feb 22, 2021• 19 citations
Publisher

Abstract

We report a chip-scale atomic magnetometer based on coherent population trapping, which can operate near zero magnetic field. By exploiting the asymmetric population among magnetic sublevels in the hyperfine ground state of cesium, we observe that the resonance signal acquires sensitivity to magnetic field in spite of degeneracy. A dispersive signal for magnetic field discrimination is obtained near-zero-field as well as for finite fields (tens of micro-tesla) in a chip-scale device of 0.94 cm3 volume. This shows that it can be readily used in low magnetic field environments, which have been inaccessible so far in miniaturized atomic magnetometers based on coherent population trapping. The measured noise floor of 300 pT/Hz1/2 at the zero-field condition is comparable to that of the conventional finite-field measurement obtained under the same conditions. This work suggests a way to implement integrated atomic magnetometers with a wide operating range.

DOI
10.3390/s21041517

Related papers

Chip-Scale SERF Atomic Magnetometer without Magnetic Shield

Lin Lu, Jintang Shang, Zhihua Pan +1 more

Atomic magnetometer operating in spin-exchange-relaxation-free (SERF) regime has a wide range of applications due to its ultra-high sensitivity. However, the requirement of operating in near-zero magnetic field restricts some of the applications which need the atomic magnetometer to work in the high field environment such as monitoring the magnetic anomalies. A novel scheme of the chip-scale SERF atomic magnetometer operating in geomagnetic field without magnetic shield is demonstrated here. A 18 bits high-precise digital-to-analog converter (DAC) is applied to ensure the stability of the compensated magnetic field. The fluctuation of the compensated magnetic field is less than 8.3nT and a measurement sensitivity of 12.4pT/Hz1/2 is achieved in the laboratory environment without any magnetic shields.

IEEE Electronic Components and Technology Conference (ECTC)•May 1, 2017•6 citations

Chip-scale atomic magnetometer

Peter D. D. Schwindt, Svenja A. Knappe, Vishal Shah +4 more

Using the techniques of microelectromechanical systems, we have constructed a small low-power magnetic sensor based on alkali atoms. We use a coherent population trapping resonance to probe the interaction of the atoms’ magnetic moment with a magnetic field, and we detect changes in the magnetic flux density with a sensitivity of 50pTHz−1∕2 at 10Hz. The magnetic sensor has a size of 12mm3 and dissipates 195mW of power. Further improvements in size, power dissipation, and magnetic field sensitivity are immediately foreseeable, and such a device could provide a hand-held battery-operated magnetometer with an atom shot-noise limited sensitivity of 0.05pTHz−1∕2.

Applied Physics Letters•Dec 17, 2004•490 citations

CPT Magnetometer with Atomic Energy Level Modulation

Liu Guo-Bin, Runchang Du, Liu Chao-Yang +1 more

We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87 Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.

Chinese Physics Letters•Feb 1, 2008•17 citations

Atomic magnetometer with microfabricated vapor cells based on coherent population trapping*

Xiaojie Li, Yuejiang Shi, Hongbo Xue +2 more

An atomic magnetometer based on coherent population trapping (CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system (MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 kHz (1.46 kHz with approximately zero laser intensity) for the rubidium D1 line at about 90 °C. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 pT/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future.

Chinese Physics B•Oct 20, 2020•8 citations

Study on the sensitivity of laser-pumped cesium atomic magnetometer

Nan Li, Huang Kai-Kai, Xuanhui Lu

A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.

Acta Physica Sinica•Jan 1, 2013•4 citations

Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique

Peter D. D. Schwindt, B. J. Lindseth, Svenja A. Knappe +3 more

The fabrication and performance of a miniature optically pumped atomic magnetometer constructed with microfabricated components are discussed. This device measures the spin precession frequency of Rb87 atoms to determine the magnetic field by use of the Mx technique. It has a demonstrated sensitivity to magnetic fields of 5pT∕Hz1∕2 for a bandwidth from 1to100Hz, nearly an order of magnitude improvement over our previous chip-scale magnetometer. The 3dB bandwidth has also been increased to 1kHz by reconfiguring the miniature vapor cell heater.

Applied Physics Letters•Feb 19, 2007•192 citations
We report a chip-scale atomic magnetometer based on coherent population trapping, which can operate near zero magnetic field. By exploiting the asymmetric population among magnetic sublevels in the hyperfine ground state of cesium, we observe that the resonance signal acquires sensitivity to magnetic field in spite of degeneracy. A dispersive signal for magnetic field discrimination is obtained near-zero-field as well as for finite fields (tens of micro-tesla) in a chip-scale device of 0.94 cm3 volume. This shows that it can be readily used in low magnetic field environments, which have been inaccessible so far in miniaturized atomic magnetometers based on coherent population trapping. The measured noise floor of 300 pT/Hz1/2 at the zero-field condition is comparable to that of the conventional finite-field measurement obtained under the same conditions. This work suggests a way to implement integrated atomic magnetometers with a wide operating range.
Atomic magnetometer operating in spin-exchange-relaxation-free (SERF) regime has a wide range of applications due to its ultra-high sensitivity. However, the requirement of operating in near-zero magnetic field restricts some of the applications which need the atomic magnetometer to work in the high field environment such as monitoring the magnetic anomalies. A novel scheme of the chip-scale SERF atomic magnetometer operating in geomagnetic field without magnetic shield is demonstrated here. A 18 bits high-precise digital-to-analog converter (DAC) is applied to ensure the stability of the compensated magnetic field. The fluctuation of the compensated magnetic field is less than 8.3nT and a measurement sensitivity of 12.4pT/Hz1/2 is achieved in the laboratory environment without any magnetic shields.
Using the techniques of microelectromechanical systems, we have constructed a small low-power magnetic sensor based on alkali atoms. We use a coherent population trapping resonance to probe the interaction of the atoms’ magnetic moment with a magnetic field, and we detect changes in the magnetic flux density with a sensitivity of 50pTHz−1∕2 at 10Hz. The magnetic sensor has a size of 12mm3 and dissipates 195mW of power. Further improvements in size, power dissipation, and magnetic field sensitivity are immediately foreseeable, and such a device could provide a hand-held battery-operated magnetometer with an atom shot-noise limited sensitivity of 0.05pTHz−1∕2.
We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87 Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.
An atomic magnetometer based on coherent population trapping (CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system (MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 kHz (1.46 kHz with approximately zero laser intensity) for the rubidium D1 line at about 90 °C. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 pT/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future.
A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.
The fabrication and performance of a miniature optically pumped atomic magnetometer constructed with microfabricated components are discussed. This device measures the spin precession frequency of Rb87 atoms to determine the magnetic field by use of the Mx technique. It has a demonstrated sensitivity to magnetic fields of 5pT∕Hz1∕2 for a bandwidth from 1to100Hz, nearly an order of magnitude improvement over our previous chip-scale magnetometer. The 3dB bandwidth has also been increased to 1kHz by reconfiguring the miniature vapor cell heater.