Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique

Peter D. D. Schwindt, B. J. Lindseth, Svenja A. Knappe, Vishal Shah, John E. Kitching, Li‐Anne Liew

Published Feb 19, 2007• 192 citations
Publisher

Abstract

The fabrication and performance of a miniature optically pumped atomic magnetometer constructed with microfabricated components are discussed. This device measures the spin precession frequency of Rb87 atoms to determine the magnetic field by use of the Mx technique. It has a demonstrated sensitivity to magnetic fields of 5pT∕Hz1∕2 for a bandwidth from 1to100Hz, nearly an order of magnitude improvement over our previous chip-scale magnetometer. The 3dB bandwidth has also been increased to 1kHz by reconfiguring the miniature vapor cell heater.

DOI
10.1063/1.2709532

Related papers

Chip Scale Atomic Magnetometers

Peter D. D. Schwindt, B. J. Lindseth, Svenja A. Knappe +5 more

An optically pumped magnetometer was drastically miniaturized, by taking advantage of MEMS techniques, producing the chip-scale atomic magnetometers (CSAM) physics package. The key component of the package is an alkali vapor cell. To probe the magnetic field experienced by the atoms, the injection current to the VCSEL was modulated at 3.4 GHz near half the hyperfine frequency of87Rb. Lock-in detection is used to determine the center of the resonance, and the magnetic field is determined by counting the modulation frequency, which is related to the Larmor precession frequency under these locked conditions. The ITO heaters create a large magnetic field gradient, which broadens the resonance and reduces the sensitivity.

IEEE International Magnetics Conference•May 1, 2006•15 citations

A Microfabricated High Performance Magnetometer

B. J. Lindseth, Peter D. D. Schwindt, Svenja A. Knappe +4 more

We report the operation of a microfabricated atomic magnetometer using the Mx configuration. A device size of a few millimeters achieves a magnetic field noise limited sensitivity of 5.9 pT/Hz1/2 over a 1-100 Hz bandwidth.

Frontiers in Optics•Jan 1, 2006•0 citations

Sensitivity Comparison of Mx and Frequency-Modulated Bell–Bloom Cs Magnetometers in a Microfabricated Cell

Ricardo Jiménez-Martínez, W. C. Griffith, Ying-Ju Wang +4 more

We compare the sensitivity performance of two optically pumped atomic magnetometers based on the Mx and frequency-modulated bell-bloom configurations. The Cs magnetometers are implemented using a millimeter-scale microfabricated vapor cell. It is found that the Bell-Bloom magnetometer yields sensitivities similar to those of the Mx magnetometer when operated under equally optimized conditions. The Bell-Bloom approach offers several attractive features over the Mx approach for chip-scale magnetometer instrumentation.

IEEE Transactions on Instrumentation and Measurement•Sep 18, 2009•84 citations

Pulsed operation of a miniature scalar optically pumped magnetometer

Vladislav P. Gerginov, Sean Krzyzewski, Svenja A. Knappe

A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.

Journal of the Optical Society of America B•Jun 15, 2017•58 citations

Sensitivity Comparison of Mx and Frequency Modulated Bell-Bloom Cs Magnetometers in a Micro-Fabricated Cell

Ricardo Jiménez-Martínez, Clark Griffith, Svenja A. Knappe +1 more

We compare the sensitivity of two optically pumped atomic magnetometers, Mx and frequency-modulated Bell-Bloom magnetometer implemented in a single pump-probe beam configuration and using a microfabricated vapor cell filled with 133Cs and N2 buffer gas.

Frontiers in Optics•Jan 1, 2008•2 citations

Microfabricated Spin Polarized Atomic Magnetometers

Ricardo Jiménez-Martínez

Spin polarized atomic magnetometers involve the preparation of atomic spins and their detection for monitoring magnetic fields. Due to the fact that magnetic fields are ubiquitous in our world, spin polarized atomic magnetometers are used in a wide range of applications from the detection of magnetic fields generated by the human heart and brain to the detection of nuclear magnetic resonance. In this thesis we developed microfabricated spin polarized atomic magnetometers. These sensors are based on optical pumping and spin-exchange collisions between alkali atoms and noble gases contained in microfabricated millimeter-scale vapor cells. In the first part of the thesis, we improved different features of current microfabricated optical magnetometers. Specifically, we improved the bandwidth of these devices, without degrading their magnetic field sensitivity, by broadening their magnetic resonance through spin-exchange collisions between alkali atoms. We also implemented all-optical excitation techniques to avoid problems, such as the magnetic perturbation of the environment, induced by the radio-frequency fields used in some of these sensors. In the second part of the thesis we demonstrated a microfluidic chip for the optical production and detection of hyperpolarized Xe gas through spin-exchange collisions with optically pumped Rb atoms. These devices are critical for the widespread use of spin polarized atomic magnetometers in applications requiring simple, compact, low-cost, and portable instrumentation.

•Jan 1, 2013•2 citations
The fabrication and performance of a miniature optically pumped atomic magnetometer constructed with microfabricated components are discussed. This device measures the spin precession frequency of Rb87 atoms to determine the magnetic field by use of the Mx technique. It has a demonstrated sensitivity to magnetic fields of 5pT∕Hz1∕2 for a bandwidth from 1to100Hz, nearly an order of magnitude improvement over our previous chip-scale magnetometer. The 3dB bandwidth has also been increased to 1kHz by reconfiguring the miniature vapor cell heater.
An optically pumped magnetometer was drastically miniaturized, by taking advantage of MEMS techniques, producing the chip-scale atomic magnetometers (CSAM) physics package. The key component of the package is an alkali vapor cell. To probe the magnetic field experienced by the atoms, the injection current to the VCSEL was modulated at 3.4 GHz near half the hyperfine frequency of87Rb. Lock-in detection is used to determine the center of the resonance, and the magnetic field is determined by counting the modulation frequency, which is related to the Larmor precession frequency under these locked conditions. The ITO heaters create a large magnetic field gradient, which broadens the resonance and reduces the sensitivity.
We compare the sensitivity performance of two optically pumped atomic magnetometers based on the Mx and frequency-modulated bell-bloom configurations. The Cs magnetometers are implemented using a millimeter-scale microfabricated vapor cell. It is found that the Bell-Bloom magnetometer yields sensitivities similar to those of the Mx magnetometer when operated under equally optimized conditions. The Bell-Bloom approach offers several attractive features over the Mx approach for chip-scale magnetometer instrumentation.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
Spin polarized atomic magnetometers involve the preparation of atomic spins and their detection for monitoring magnetic fields. Due to the fact that magnetic fields are ubiquitous in our world, spin polarized atomic magnetometers are used in a wide range of applications from the detection of magnetic fields generated by the human heart and brain to the detection of nuclear magnetic resonance. In this thesis we developed microfabricated spin polarized atomic magnetometers. These sensors are based on optical pumping and spin-exchange collisions between alkali atoms and noble gases contained in microfabricated millimeter-scale vapor cells. In the first part of the thesis, we improved different features of current microfabricated optical magnetometers. Specifically, we improved the bandwidth of these devices, without degrading their magnetic field sensitivity, by broadening their magnetic resonance through spin-exchange collisions between alkali atoms. We also implemented all-optical excitation techniques to avoid problems, such as the magnetic perturbation of the environment, induced by the radio-frequency fields used in some of these sensors. In the second part of the thesis we demonstrated a microfluidic chip for the optical production and detection of hyperpolarized Xe gas through spin-exchange collisions with optically pumped Rb atoms. These devices are critical for the widespread use of spin polarized atomic magnetometers in applications requiring simple, compact, low-cost, and portable instrumentation.