Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

High-precision cavity spectroscopy using high-frequency squeezed light

J. Junker, D. M. Wilken, Elanor H. Huntington, M. Heurs

Published Jan 15, 2021• 13 citations
Publisher

Abstract

In this article, we present a novel spectroscopy technique that improves the signal-to-shot-noise ratio without the need to increase the laser power. Detrimental effects by technical noise sources are avoided by frequency-modulation techniques (frequency up-shifting). Superimposing the signal on non-classical states of light leads to a reduced quantum noise floor. Our method reveals in a proof-of-concept experiment small signals at Hz to kHz frequencies even below the shot noise limit. Our theoretical calculations fully support our experimental findings. The proposed technique is interesting for applications such as high-precision cavity spectroscopy, e.g., for explosive trace gas detection where the specific gas might set an upper limit for the laser power employed.

DOI
10.1364/oe.416713

Related papers

Laser Power Stabilization beyond the Shot Noise Limit Using Squeezed Light

H. Vahlbruch, D. M. Wilken, Moritz Mehmet +1 more

High levels of laser power stability are necessary for high precision metrology applications. The classical limit for the achievable power stability is determined by the shot noise of the light used to generate a power control signal. Increasing the power of the detected light reduces the relative shot noise level and allows higher stabilities. However, sufficiently high power is not always available and the detection of high laser powers is challenging. Here, we demonstrate a nonclassical way to improve the achievable power stability without increasing the detected power. By the injection of a squeezed vacuum field of light we improve the classical laser power stability beyond its shot noise limit by 9.4_{-0.6}^{+0.6} dB at Fourier frequencies between 5 and 80 kHz. For only 90.6 μA of detected photocurrent we achieve a relative laser power noise of 2.0_{-0.1}^{+0.1}×10^{-8}/sqrt[Hz]. This is the first demonstration of a squeezed light-enhanced laser power stabilization and its performance is equivalent to an almost tenfold increase of detected laser power in a classical scheme. The analysis reveals that the technique presented here has the potential to achieve stability levels of 4.2×10^{-10}/sqrt[Hz] with 58 mA photocurrent measured on a single photodetector.

Physical Review Letters•Oct 22, 2018•64 citations

Squeezed light for the interferometric detection of high-frequency gravitational waves

Roman Schnabel, J. Harms, K. A. Strain +1 more

The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.

arXiv:gr-qc/0401119•Classical and Quantum Gravity•Feb 12, 2004•27 citations

Quantum-Enhanced Absorption Spectroscopy with Bright Squeezed Frequency Combs

Alexandre Belsley

Absorption spectroscopy is a widely used technique that permits the detection and characterization of gas species at low concentrations. We propose a sensing strategy combining the advantages of frequency modulation spectroscopy with the reduced noise properties accessible by squeezing the probe state. A homodyne detection scheme allows the simultaneous measurement of the absorption at multiple frequencies and is robust against dispersion across the absorption profile. We predict a significant enhancement of the signal-to-noise ratio that scales exponentially with the squeezing factor. An order of magnitude improvement beyond the standard quantum limit is possible with state-of-the-art squeezing levels facilitating high precision gas sensing.

arXiv:2209.15628•Physical Review Letters•Mar 28, 2023•30 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, Harry J. Kimble

An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.

Physical Review Letters•Jul 20, 1987•731 citations

Bright squeezed light generation via nonclassical power stabilization

Jasper R. Venneberg, H. Vahlbruch, Marina Trad Nery +1 more

Low-power-noise lasers are essential for many high-precision experiments. Shot noise imposes a fundamental limit on the power stability achievable with classical light sources. In this Letter, we report the generation of bright squeezed light in the audio band, which can improve the sensitivity of otherwise shot-noise-limited measurements. The bright squeezed light source is experimentally realized via the use of squeezed vacuum in a power stabilization scheme. We demonstrate a laser beam at a power of 9.9 mW with a broadband power noise suppression below the classical stabilization limit by up to 8 . 7 − 0.4 + 0.3 dB in the audio band, resulting in a bright squeezed beam with a power noise of 5 . 7 − 0.4 + 0.3 dB below shot noise for frequencies from 6 kHz to 20 kHz. We further conceptually outline a method to surpass this result in the future.

Physical Review Research•May 20, 2025•7 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations
In this article, we present a novel spectroscopy technique that improves the signal-to-shot-noise ratio without the need to increase the laser power. Detrimental effects by technical noise sources are avoided by frequency-modulation techniques (frequency up-shifting). Superimposing the signal on non-classical states of light leads to a reduced quantum noise floor. Our method reveals in a proof-of-concept experiment small signals at Hz to kHz frequencies even below the shot noise limit. Our theoretical calculations fully support our experimental findings. The proposed technique is interesting for applications such as high-precision cavity spectroscopy, e.g., for explosive trace gas detection where the specific gas might set an upper limit for the laser power employed.
High levels of laser power stability are necessary for high precision metrology applications. The classical limit for the achievable power stability is determined by the shot noise of the light used to generate a power control signal. Increasing the power of the detected light reduces the relative shot noise level and allows higher stabilities. However, sufficiently high power is not always available and the detection of high laser powers is challenging. Here, we demonstrate a nonclassical way to improve the achievable power stability without increasing the detected power. By the injection of a squeezed vacuum field of light we improve the classical laser power stability beyond its shot noise limit by 9.4_{-0.6}^{+0.6} dB at Fourier frequencies between 5 and 80 kHz. For only 90.6 μA of detected photocurrent we achieve a relative laser power noise of 2.0_{-0.1}^{+0.1}×10^{-8}/sqrt[Hz]. This is the first demonstration of a squeezed light-enhanced laser power stabilization and its performance is equivalent to an almost tenfold increase of detected laser power in a classical scheme. The analysis reveals that the technique presented here has the potential to achieve stability levels of 4.2×10^{-10}/sqrt[Hz] with 58 mA photocurrent measured on a single photodetector.
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.
Absorption spectroscopy is a widely used technique that permits the detection and characterization of gas species at low concentrations. We propose a sensing strategy combining the advantages of frequency modulation spectroscopy with the reduced noise properties accessible by squeezing the probe state. A homodyne detection scheme allows the simultaneous measurement of the absorption at multiple frequencies and is robust against dispersion across the absorption profile. We predict a significant enhancement of the signal-to-noise ratio that scales exponentially with the squeezing factor. An order of magnitude improvement beyond the standard quantum limit is possible with state-of-the-art squeezing levels facilitating high precision gas sensing.
An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.
Low-power-noise lasers are essential for many high-precision experiments. Shot noise imposes a fundamental limit on the power stability achievable with classical light sources. In this Letter, we report the generation of bright squeezed light in the audio band, which can improve the sensitivity of otherwise shot-noise-limited measurements. The bright squeezed light source is experimentally realized via the use of squeezed vacuum in a power stabilization scheme. We demonstrate a laser beam at a power of 9.9 mW with a broadband power noise suppression below the classical stabilization limit by up to 8 . 7 − 0.4 + 0.3 dB in the audio band, resulting in a bright squeezed beam with a power noise of 5 . 7 − 0.4 + 0.3 dB below shot noise for frequencies from 6 kHz to 20 kHz. We further conceptually outline a method to surpass this result in the future.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.