Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Robust Weak Measurements on Finite Samples

Jeff Tollaksen

Published Mar 5, 2007• 10 citations
OpenAlex

Abstract

A new weak measurement procedure is introduced for finite samples which yields accurate weak values that are outside the range of eigenvalues and which do not require an exponentially rare ensemble. This procedure provides a unique advantage in the amplification of small non-random signals by minimizing uncertainties in determining the weak value and by minimizing sample size. This procedure can also extend the strength of the coupling between the system and measuring device to a new regime. 1

Related papers

Robust weak measurements on finite samples

Jeff Tollaksen

A new weak measurement procedure is introduced for finite samples which yields accurate weak values that are outside the range of eigenvalues and which do not require an exponentially rare ensemble. This procedure provides a unique advantage in the amplification of small nonrandom signals by minimizing uncertainties in determining the weak value and by minimizing sample size. This procedure can also extend the strength of the coupling between the system and measuring device to a new regime.

arXiv:quant-ph/0703038•Journal of Physics Conference Series•May 1, 2007•11 citations

Non-statistical Weak Measurements

Jeff Tollaksen, Yakir Aharonov (a

Non-statistical weak measurements yield weak values that are outside the range of eigenvalues and are not rare, suggesting that weak values are a property of every pre-and-post-selected ensemble. They also extend the applicability and valid regime of weak values.

•Jul 28, 2006•12 citations

Weak Measurements

Lev Vaidman A

Weak measurement is a standard measuring procedure with two changes: it is performed on pre- and post-selected quantum systems and the coupling to the measuring device is weakened. The outcomes of weak measurements, ``weak values'' are very different for the eigenvalues of the measured operators. The weak values yield novel rich structure of the quantum world. Weak values help explaining peculiar quantum phenomena and finding new effects which might have practical applications.

arXiv:hep-th/9408154•Aug 28, 1994•10 citations

Experimental realization of robust weak measurements

Enrico Rebufello, Fabrizio Piacentini, Alessio Avella +7 more

Despite being very influential on both foundations and applications of quantum mechanics, weak values are still somewhat controversial. Although there are some indications that weak values are physical properties of a single quantum system, the common way weak values are presented is statistical: it is commonly believed that for measuring weak values one has to perform many weak measurements over a large ensemble of pre- and postselected particles. Other debates surround the anomalous nature of weak value and even their quantumness. To address these issues, we present some preliminary data showing that anomalous weak values can be measured using just a single detection, i.e. with no statistics. In our experiment, a single click of a detector indicates the weak value as a single photon property, which moreover lies well beyond the range of eigenvelues of the measured operator. Importantly, the uncertainty with which the weak values is measured is smaller than the difference between the weak value and the closet eigenvalue. This is the first experimental realization of robust weak measurements.

Optical and Quantum Sensing and Precision Metrology II•Feb 25, 2020•0 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Measurement of a Weak Value

Randall G. Hulet, Nicholas W. M. Ritchie, J. G. Story

Abstract "Weak measurements" are measurements in which the coupling between the measuring device and the observable to be measured is so weak that the eigenvalues of the observable are not resolved. Under certain circumstances the corresponding eigenfunctions can be made to interfere, producing a measurement result which is outside the allowed range of the observable's eigenvalues. We present the first measurement of this so-called "weak value" using an optical experiment. In our experiment, the small displacement between the two orthogonally polarized components of a laser beam passed through a birefringence crystal is measured. We use a numerical simulation to show that this phenomenon may be practical for detecting and amplifying small effects.

Zeitschrift für Naturforschung A•Feb 1, 1997•0 citations
A new weak measurement procedure is introduced for finite samples which yields accurate weak values that are outside the range of eigenvalues and which do not require an exponentially rare ensemble. This procedure provides a unique advantage in the amplification of small non-random signals by minimizing uncertainties in determining the weak value and by minimizing sample size. This procedure can also extend the strength of the coupling between the system and measuring device to a new regime. 1
Despite being very influential on both foundations and applications of quantum mechanics, weak values are still somewhat controversial. Although there are some indications that weak values are physical properties of a single quantum system, the common way weak values are presented is statistical: it is commonly believed that for measuring weak values one has to perform many weak measurements over a large ensemble of pre- and postselected particles. Other debates surround the anomalous nature of weak value and even their quantumness. To address these issues, we present some preliminary data showing that anomalous weak values can be measured using just a single detection, i.e. with no statistics. In our experiment, a single click of a detector indicates the weak value as a single photon property, which moreover lies well beyond the range of eigenvelues of the measured operator. Importantly, the uncertainty with which the weak values is measured is smaller than the difference between the weak value and the closet eigenvalue. This is the first experimental realization of robust weak measurements.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Abstract "Weak measurements" are measurements in which the coupling between the measuring device and the observable to be measured is so weak that the eigenvalues of the observable are not resolved. Under certain circumstances the corresponding eigenfunctions can be made to interfere, producing a measurement result which is outside the allowed range of the observable's eigenvalues. We present the first measurement of this so-called "weak value" using an optical experiment. In our experiment, the small displacement between the two orthogonally polarized components of a laser beam passed through a birefringence crystal is measured. We use a numerical simulation to show that this phenomenon may be practical for detecting and amplifying small effects.