Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America A

Detecting squeezed light with a photomultiplier

Richard A. Campus, Malvin Carl Teich, Bahaa E. A. Saleh

Published Jan 1, 1987• 0 citations
OpenAlex

Related papers

Pulsed Squeezed Light

Richard E. Slusher, Arthur LaPorta, Philippe Grangier +1 more

NATO ASI series. Series B : Physics•Jan 1, 1989•2 citations

Detecting squeezed light with a photomultiplier tube: the cosmic-ray connection

Richard A. Campus, Malvin Carl Teich, Bahaa E. A. Saleh

A number of experiments have been carried out in which quadrature and photon-number squeezed light have been generated. The signature of both is a sub-Poisson photoelectron number (or equivalently a sub-shot-noise photoelectron current). The photomultiplier tube (PMT), with a large amplification and low excess noise factor, is often a preferred detector in such experiments. The detectability of nonclassical light by a PMT can be reduced by the presence of background noise, the most deleterious of which is caused by Cherenkov photon emissions from clustered cosmic-ray cascade particles as they transverse the faceplate of the PMT. We have empirically determined that cosmic-ray events can be substantially avoided by using experimental durations of less than tens of seconds. However, for experiments that cannot be conducted in such short periods of time, cosmic- ray clusters may pose a significant limitation. The fluctuations of extensive air-shower particles at ground level turn out to be well described by the two-parameter Poisson-driven Yule-Furry or by the negative-binomial counting distribution. Experimental results for various PMTs operated in the dark are presented along with theoretical predictions.

Annual Meeting Optical Society of America•Jan 1, 1987•0 citations

Squeezed Light in an Interferometer

Ray LaPierre

Undergraduate texts in physics•Jan 1, 2022•0 citations

Theory and Applications of Josephson Photomultipliers

Luke C. G. Govia

This thesis describes the back action of microwave-photon detection via a Josephson photomultiplier (JPM), a superconducting qubit coupled strongly to a high-quality mi- crowave cavity, and the applications of these devices. The back action operator depends qualitatively on the duration of the measurement interval, resembling the regular photon annihilation operator at short interaction times and approaching a variant of the photon subtraction operator at long times. The optimal operating conditions of the JPM differ from those considered optimal for processing and storing of quantum information, in that a short T2 of the JPM suppresses the cavity dephasing incurred during measurement. Un- derstanding this back action opens the possibility to perform multiple JPM measurements on the same state, hence performing efficient state tomography. In addition, this the- sis describes the creation of non-classical states of microwave radiation via single photon detection using JPMs. When operated in the low T2 regime, the back action of a JPM resembles the photon subtraction operator. Using the non-linearity of this back action, it is possible to create non-classical states of microwave radiation, including squeezed vacuum and odd Schro ̈dinger cat states, starting from a coherent state.

•Aug 31, 2012•0 citations

Generation of Squeezed Light

E. Giacobino

Springer proceedings in physics•Jan 1, 1991•0 citations

High sensitivity third-order autocorrelation measurement by intensity modulation and third harmonic detection

Yizhen Wei, Scott S. Howard, Adam A. Straub +4 more

We demonstrate a novel (to our knowledge) method for high sensitivity measurement of pulsed light at the telecommunication wavelength of 1558 nm using a GaAsP photomultiplier tube. By modulating the input power and analyzing the harmonic components, high sensitivity third-order autocorrelation is obtained in the wavelength and power regimes where a mixture of two-photon absorption and three-photon absorption in the photomultiplier tube is present.

Optics Letters•Jun 15, 2011•14 citations
A number of experiments have been carried out in which quadrature and photon-number squeezed light have been generated. The signature of both is a sub-Poisson photoelectron number (or equivalently a sub-shot-noise photoelectron current). The photomultiplier tube (PMT), with a large amplification and low excess noise factor, is often a preferred detector in such experiments. The detectability of nonclassical light by a PMT can be reduced by the presence of background noise, the most deleterious of which is caused by Cherenkov photon emissions from clustered cosmic-ray cascade particles as they transverse the faceplate of the PMT. We have empirically determined that cosmic-ray events can be substantially avoided by using experimental durations of less than tens of seconds. However, for experiments that cannot be conducted in such short periods of time, cosmic- ray clusters may pose a significant limitation. The fluctuations of extensive air-shower particles at ground level turn out to be well described by the two-parameter Poisson-driven Yule-Furry or by the negative-binomial counting distribution. Experimental results for various PMTs operated in the dark are presented along with theoretical predictions.
This thesis describes the back action of microwave-photon detection via a Josephson photomultiplier (JPM), a superconducting qubit coupled strongly to a high-quality mi- crowave cavity, and the applications of these devices. The back action operator depends qualitatively on the duration of the measurement interval, resembling the regular photon annihilation operator at short interaction times and approaching a variant of the photon subtraction operator at long times. The optimal operating conditions of the JPM differ from those considered optimal for processing and storing of quantum information, in that a short T2 of the JPM suppresses the cavity dephasing incurred during measurement. Un- derstanding this back action opens the possibility to perform multiple JPM measurements on the same state, hence performing efficient state tomography. In addition, this the- sis describes the creation of non-classical states of microwave radiation via single photon detection using JPMs. When operated in the low T2 regime, the back action of a JPM resembles the photon subtraction operator. Using the non-linearity of this back action, it is possible to create non-classical states of microwave radiation, including squeezed vacuum and odd Schro ̈dinger cat states, starting from a coherent state.