Optics Letters

High sensitivity third-order autocorrelation measurement by intensity modulation and third harmonic detection

Yizhen Wei, Scott S. Howard, Adam A. Straub, Zinan Wang, Ji Cheng, Shiming Gao, Chris Xu

Published Jun 15, 2011• 14 citations
Publisher

Abstract

We demonstrate a novel (to our knowledge) method for high sensitivity measurement of pulsed light at the telecommunication wavelength of 1558 nm using a GaAsP photomultiplier tube. By modulating the input power and analyzing the harmonic components, high sensitivity third-order autocorrelation is obtained in the wavelength and power regimes where a mixture of two-photon absorption and three-photon absorption in the photomultiplier tube is present.

DOI
10.1364/ol.36.002372

Related papers

Femtosecond scale photon-triplet counting and third order autocorrelations in a photomultiplier tube

Amir Nevet, Alex Hayat, Meir Orenstein

Three-photon counting at ultrashort timescale by ultrasensitive three-photon absorption is demonstrated experimentally. This is a unique tool for ultrafast quantum state characterization as well as for complete determination of temporal photon-shapes.

Nonlinear Optics•Jan 1, 2011•0 citations

Interferometric autocorrelation in the ultraviolet utilizing spontaneous parametric down-conversion inside an enhancement cavity

Patrick Michelberger, Roland Krischek, Witlef Wieczorek +2 more

Autocorrelation is a common method to estimate the duration of ultrashort laser pulses. In the ultraviolet (UV) regime it is challenging to employ the process of second-harmonic generation, most prominently due to absorption in nonlinear crystals at very short wavelengths. Here we show how to utilize spontaneous parametric down-conversion (SPDC) to generate an autocorrelation signal in the infrared (IR) for UV pulses. Our method utilizes the nth-order emission of the SPDC process, which occurs for low pumping powers proportional to the nth power of the UV intensity. Thus, counting 2n down-converted photons directly yields the nth-order autocorrelation. The method, now with detection of near-IR photons, is applied to the first direct measurement of ultrashort UV pulses circulating inside a UV enhancement cavity.

arXiv:1706.01110•Optics Letters•Mar 26, 2012•2 citations

Femtosecond Three-Photon Counting in a Photomultiplier Tube

Amir Nevet, Alex Hayat, Meir Orenstein

We demonstrate experimentally ultrafast three-photon counting by three-photon absorption in a photomultiplier tube, which may serve as a unique tool for ultrafast quantum state characterization as well as for ultrasensitive temporal measurements.

Advanced Photonics•Jan 1, 2011•0 citations

Three-photon counting in a photomultiplier tube for ultrafast source characterization

Amir Nevet, Alex Hayat, Meir Orenstein

We demonstrate experimentally ultrafast three-photon counting by three-photon absorption in a photomultiplier tube, which may serve as a unique tool for ultrafast quantum state characterization as well as for ultrasensitive temporal measurements.

Conference on Lasers and Electro-Optics•Jan 1, 2011•0 citations

Ultrasensitive N -Photon Interferometric Autocorrelator

Zili Zhou, G. Frucci, F. Mattioli +5 more

We demonstrate a novel method to measure Nth-order (N=1,2,3,4) interferometric autocorrelation with high sensitivity and temporal resolution. It is based on the combination of linear absorption and nonlinear detection in a superconducting nanodetector, providing much higher efficiency than methods based on all-optical nonlinearities. Its temporal resolution is only limited by the quasiparticle energy relaxation time, which is directly measured to be in the 20 ps range for the NbN films used in this work. We present a general model of interferometric autocorrelation with these nonlinear detectors and discuss the comparison with other approaches and possible improvements.

arXiv:1209.2747•Physical Review Letters•Mar 28, 2013•20 citations

Measurements of photon correlations in quasi-coherent optical fields

J. Klebba

The purpose of this investigation was to construct the experimental apparatus for measuring second-order intensity correlation functions of the type T2,2 (x,t,x,t+T) = < : I(x,t)I(x,t+T):>. This measurement was applied to the radiation field produced by a two axial mode Helium-Neon gas laser in order to verify the intensity fluctuation correlations due to the beating of the two axial modes of the laser. The axial mode separation was measured for comparison with a scanning Fabry Perot interferometer and also an RF spectrum analyzer. The correlation measurement was also applied to the second harmonic radiation field produced by the. parametric interaction in a LiNb03 crystal pumped with two axial modes. The experimental determination of the correlation <:I(x,t)I(x,t+T):> involves a time-spectroscopy measurement in which one photon is detected at point x, and another at point x, T seconds later, and measuring the probability of two-fold coincident detection as a function of T. The radiation field was split into two beams at a partially transmitting reflector, each of which was directed incident on the photocathode of a photomultiplier tube. The photoelectron pulses from the tubes were amplified and standardized. These standardized pulses were then temporally correlated with the use of a time-to-amplitude converter (TAC) and a multi-channel pulse height analyzer (MA). The time-to-amplitude conversions generated by the TAC were stored in the channels of the PHA, which was a direct measure of the two-fold delayed coincidence detection rate, R(T). The second-order intensity correlation functions <:I(x,t)I(x,t+T):> are determined from measurements of R(T). The fluctuating components of the second-order intensity correlation functions were found to be in agreement with what would be expected on a classical basis. Correspondingly, the capability is demonstrated of the experimental apparatus measuring a quantity relating to the second-order intensity correlation function.

•Jan 1, 1970•0 citations
We demonstrate a novel (to our knowledge) method for high sensitivity measurement of pulsed light at the telecommunication wavelength of 1558 nm using a GaAsP photomultiplier tube. By modulating the input power and analyzing the harmonic components, high sensitivity third-order autocorrelation is obtained in the wavelength and power regimes where a mixture of two-photon absorption and three-photon absorption in the photomultiplier tube is present.
Autocorrelation is a common method to estimate the duration of ultrashort laser pulses. In the ultraviolet (UV) regime it is challenging to employ the process of second-harmonic generation, most prominently due to absorption in nonlinear crystals at very short wavelengths. Here we show how to utilize spontaneous parametric down-conversion (SPDC) to generate an autocorrelation signal in the infrared (IR) for UV pulses. Our method utilizes the nth-order emission of the SPDC process, which occurs for low pumping powers proportional to the nth power of the UV intensity. Thus, counting 2n down-converted photons directly yields the nth-order autocorrelation. The method, now with detection of near-IR photons, is applied to the first direct measurement of ultrashort UV pulses circulating inside a UV enhancement cavity.
We demonstrate a novel method to measure Nth-order (N=1,2,3,4) interferometric autocorrelation with high sensitivity and temporal resolution. It is based on the combination of linear absorption and nonlinear detection in a superconducting nanodetector, providing much higher efficiency than methods based on all-optical nonlinearities. Its temporal resolution is only limited by the quasiparticle energy relaxation time, which is directly measured to be in the 20 ps range for the NbN films used in this work. We present a general model of interferometric autocorrelation with these nonlinear detectors and discuss the comparison with other approaches and possible improvements.
The purpose of this investigation was to construct the experimental apparatus for measuring second-order intensity correlation functions of the type T2,2 (x,t,x,t+T) = < : I(x,t)I(x,t+T):>. This measurement was applied to the radiation field produced by a two axial mode Helium-Neon gas laser in order to verify the intensity fluctuation correlations due to the beating of the two axial modes of the laser. The axial mode separation was measured for comparison with a scanning Fabry Perot interferometer and also an RF spectrum analyzer. The correlation measurement was also applied to the second harmonic radiation field produced by the. parametric interaction in a LiNb03 crystal pumped with two axial modes. The experimental determination of the correlation <:I(x,t)I(x,t+T):> involves a time-spectroscopy measurement in which one photon is detected at point x, and another at point x, T seconds later, and measuring the probability of two-fold coincident detection as a function of T. The radiation field was split into two beams at a partially transmitting reflector, each of which was directed incident on the photocathode of a photomultiplier tube. The photoelectron pulses from the tubes were amplified and standardized. These standardized pulses were then temporally correlated with the use of a time-to-amplitude converter (TAC) and a multi-channel pulse height analyzer (MA). The time-to-amplitude conversions generated by the TAC were stored in the channels of the PHA, which was a direct measure of the two-fold delayed coincidence detection rate, R(T). The second-order intensity correlation functions <:I(x,t)I(x,t+T):> are determined from measurements of R(T). The fluctuating components of the second-order intensity correlation functions were found to be in agreement with what would be expected on a classical basis. Correspondingly, the capability is demonstrated of the experimental apparatus measuring a quantity relating to the second-order intensity correlation function.