Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

ESASP

Ion trap frequency standard research at PTB

D. Schnier, A. Bauch, R. Schroeder, Chr. Tamm

Published Jun 1, 1992• 2 citations
OpenAlex

Related papers

Progress on Linear Ion Trap Mercury-Ion Frequency Standard

Hao Liu, Yuna Yang, Yuehong He +5 more

Lecture notes in electrical engineering•Jan 1, 2013•4 citations

High Stability Frequency Standards Based on (sup 1999)Hg+Ions in a Linear Ion Trap

Robert L. Tjoelker, John D. Prestage, Lute Maleki

•Aug 1, 1994•0 citations

Trapped Ion Frequency Standard

Liam Lewis, T. E. Smith, Samuel R. Stein

Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting•Jan 1, 1988•0 citations

Analysis of thermal radiation in ion traps for optical frequency standards

M Doležal, Petr Balling, Peter B. R. Nisbet-Jones +16 more

Abstract In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the ac Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for five ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10 −18 range for optical clocks based on the Sr + and Yb + E2 transitions, and even lower for Yb + E3, In + and Al + . Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.

arXiv:1510.05556•Metrologia•Nov 12, 2015•67 citations

Optical Clocks with Trapped Ions: Establishing the 10–18 Uncertainty Range

E. Peik

Great progress has been made in the development of atomic clocks at optical frequencies and a number of different systems have recently been evaluated with systematic uncertainties in the range of 10 –18 . Comparisons of frequencies and frequency ratios are now performed to affirm these evaluations, and can also lead to improved tests of relativity and fundamental principles. This paper gives a brief overview of recent improvements in the generation and transfer of stable optical frequencies and focuses on recent work done with the 171 Yb + frequency standards at PTB.

Laser Spectroscopy•Oct 5, 2016•0 citations

The Trapped Ion Frequency Standard: Current Status and Future Prospects

Lute Maleki

•Jan 1, 1995•0 citations
Abstract In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the ac Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for five ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10 −18 range for optical clocks based on the Sr + and Yb + E2 transitions, and even lower for Yb + E3, In + and Al + . Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.
Great progress has been made in the development of atomic clocks at optical frequencies and a number of different systems have recently been evaluated with systematic uncertainties in the range of 10 –18 . Comparisons of frequencies and frequency ratios are now performed to affirm these evaluations, and can also lead to improved tests of relativity and fundamental principles. This paper gives a brief overview of recent improvements in the generation and transfer of stable optical frequencies and focuses on recent work done with the 171 Yb + frequency standards at PTB.