Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser Spectroscopy

Optical Clocks with Trapped Ions: Establishing the 10–18 Uncertainty Range

E. Peik

Published Oct 5, 2016• 0 citations
Publisher

Abstract

Great progress has been made in the development of atomic clocks at optical frequencies and a number of different systems have recently been evaluated with systematic uncertainties in the range of 10 –18 . Comparisons of frequencies and frequency ratios are now performed to affirm these evaluations, and can also lead to improved tests of relativity and fundamental principles. This paper gives a brief overview of recent improvements in the generation and transfer of stable optical frequencies and focuses on recent work done with the 171 Yb + frequency standards at PTB.

DOI
10.1142/9789813200616_0005

Related papers

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•47 citations

Trapped-ion optical Atomic Clocks at the Quantum Limits

David R. Leibrandt, Samuel M. Brewer, Jwo-Sy Chen +4 more

Frequency and its inverse, time, are the most accurately measured quantities. Historically, improvements in the accuracy of clocks have enabled advances in navigation, communication, and science. Since 1967, the definition of the International System (SI) second has been based on the frequency of a microwave transition in cesium, and present day cesium atomic clocks have a fractional uncertainty near 10-16. Recently, a new type of atomic clock based on optical transitions has been developed, with a current fractional uncertainty near 10-18 (approximately one second divided by the age of the universe), and they are rapidly improving. This talk presents a brief summary of the development of optical atomic clocks, with a focus on the Al+ quantum-logic clock developed at NIST. We discuss the current state-of-the-art in optical clock performance, and describe new applications in sensing and fundamental physics. Future directions in optical atomic clock research are also considered.

Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting•Mar 7, 2017•2 citations

Evaluation of an In+ Coulomb crystal clock with relative uncertainties in the low 10−18 range

H. N. Hausser

Clocks have been among the most accurate man-made devices for centuries. Atomic clocks, which have been defining time by means of a microwave transition in the 133Cs atom since 1967, represent a major step in this development. A redefinition of the SI unit of time based on optical atomic clocks is currently under discussion. This forthcoming redefinition requires, among other criteria, the repeated demonstration of the consistency of different optical frequency standards in the low 10−18 range. In this work, the first evaluation of the systematic shifts and their uncertainties in a 115In+–172Yb+ Coulomb crystal clock is presented. This clock utilizes the 1S0 ↔ 3P0 transition in 115In+. 172Yb+ ions are co-trapped with the 115In+ ions in a segmented Paul trap and used for sympathetic cooling. With a systematic uncertainty of 2.5×10−18 when operating with a 1In+–3Yb+ crystal and 2.6×10−18 when operating with a 2In+–4Yb+ crystal, this clock is one of the most accurate clocks in the world. In addition, the operation of the clock with multiple clock ions is the first of its kind at this level of uncertainty. Measurements with up to four clock ions show a reduction in instability from 1.6×10−15/√ τ for a single indium ion to 9.2(4)×10−16/√τ when operating with four indium ions. By using an additional quench laser, the instability in another series of measurements was reduced from a single-ion instability of 1.5×10−15/√ τ to a four-ion instability of 7.1(15)×10−16/√τ , which is consistent with the expected scaling of 1/√N with the number of clock ions N. In this work, the hyperfine structure of the 3P0 ↔ 1P1 transition used for quenching was also resolved for the first time and the hyperfine constants were determined to be AHFS = 265.42(75)MHz and BHFS = 291.4(135) MHz. In frequency comparisons with other clocks, the optical frequency ratios 115In+/171Yb+(E3) and 115In+/87Sr were determined. With a relative total uncertainty of 4.2 × 10−18, the former ratio is the most accurate frequency ratio of different species published to date. It is also the first to meet one of the requirements defined on the roadmap for redefining the SI unit of the second: Measurements of frequency ratios with relative total measurement uncertainties below 5 × 10−18. The determination of the absolute frequency results in an uncertainty of 1.3 × 10−16 for the 1S0 ↔ 3P0 transition in 115In+, which is limited by that of the cesium fountains. The results obtained summarized: ν115In+ ν171Yb+(E3) =1.973 773 591 557 215 788(8) ν115In+ ν87Sr =2.952 748 749 874 860 781(27) ν115In+ =1 267 402 452 901 038.87(16) Hz

•Jan 1, 2025•0 citations

Optical Clocks with Trapped Ions: Atomic and Nuclear Clocks

E. Peik

Progress on optical clocks with laser cooled trapped ions is presented with a focus on two systems that both possess small systematic uncertainties and a high sensitivity in fundamental tests: The 171Yb+ ion with an E3 transition and the 229Th3+ ion with a low-energy nuclear transition.

Conference on Lasers and Electro-Optics•Jan 1, 2022•0 citations

Higher-order shifts of a clock frequency in Sr, Yb and Hg atoms trapped in an optical lattice

Vitalii D Ovsiannikov, Vitalii G Pal'chikov, Hidetoshi Katori

The recent progress in designing optical frequency standards with an uncertainty at a level of 10-17-10-18 requires unprecedented accuracy in estimating the role of higher-order uncertainties of optical clocks. In this paper, we systematically evaluate the multipole, nonlinear, anharmonic contributions to uncertainty of the optical-lattice-based clocks of alkaline-earth-like-atoms Sr, Yb and Hg.

European Frequency and Time Forum•Jun 1, 2014•0 citations

A multi-ion optical clock with $\mathbf{5 \times 10^{-19}}$ uncertainty

Melina Filzinger, Martin R. Steinel, Jian Jiang +4 more

Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below $1\times10^{-18}$. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of $5.3\times10^{-19}$ and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the $10^{-20}$-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of $0.6926711632159660405(20)$, with a statistical uncertainty of $0.9\times10^{-18}$ and a combined uncertainty of $2.9\times 10^{-18}$. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.

physics.atom-phCross-listedarXiv:2603.23446•Mar 25, 2026•9 citations
Great progress has been made in the development of atomic clocks at optical frequencies and a number of different systems have recently been evaluated with systematic uncertainties in the range of 10 –18 . Comparisons of frequencies and frequency ratios are now performed to affirm these evaluations, and can also lead to improved tests of relativity and fundamental principles. This paper gives a brief overview of recent improvements in the generation and transfer of stable optical frequencies and focuses on recent work done with the 171 Yb + frequency standards at PTB.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
Frequency and its inverse, time, are the most accurately measured quantities. Historically, improvements in the accuracy of clocks have enabled advances in navigation, communication, and science. Since 1967, the definition of the International System (SI) second has been based on the frequency of a microwave transition in cesium, and present day cesium atomic clocks have a fractional uncertainty near 10-16. Recently, a new type of atomic clock based on optical transitions has been developed, with a current fractional uncertainty near 10-18 (approximately one second divided by the age of the universe), and they are rapidly improving. This talk presents a brief summary of the development of optical atomic clocks, with a focus on the Al+ quantum-logic clock developed at NIST. We discuss the current state-of-the-art in optical clock performance, and describe new applications in sensing and fundamental physics. Future directions in optical atomic clock research are also considered.
Clocks have been among the most accurate man-made devices for centuries. Atomic clocks, which have been defining time by means of a microwave transition in the 133Cs atom since 1967, represent a major step in this development. A redefinition of the SI unit of time based on optical atomic clocks is currently under discussion. This forthcoming redefinition requires, among other criteria, the repeated demonstration of the consistency of different optical frequency standards in the low 10−18 range. In this work, the first evaluation of the systematic shifts and their uncertainties in a 115In+–172Yb+ Coulomb crystal clock is presented. This clock utilizes the 1S0 ↔ 3P0 transition in 115In+. 172Yb+ ions are co-trapped with the 115In+ ions in a segmented Paul trap and used for sympathetic cooling. With a systematic uncertainty of 2.5×10−18 when operating with a 1In+–3Yb+ crystal and 2.6×10−18 when operating with a 2In+–4Yb+ crystal, this clock is one of the most accurate clocks in the world. In addition, the operation of the clock with multiple clock ions is the first of its kind at this level of uncertainty. Measurements with up to four clock ions show a reduction in instability from 1.6×10−15/√ τ for a single indium ion to 9.2(4)×10−16/√τ when operating with four indium ions. By using an additional quench laser, the instability in another series of measurements was reduced from a single-ion instability of 1.5×10−15/√ τ to a four-ion instability of 7.1(15)×10−16/√τ , which is consistent with the expected scaling of 1/√N with the number of clock ions N. In this work, the hyperfine structure of the 3P0 ↔ 1P1 transition used for quenching was also resolved for the first time and the hyperfine constants were determined to be AHFS = 265.42(75)MHz and BHFS = 291.4(135) MHz. In frequency comparisons with other clocks, the optical frequency ratios 115In+/171Yb+(E3) and 115In+/87Sr were determined. With a relative total uncertainty of 4.2 × 10−18, the former ratio is the most accurate frequency ratio of different species published to date. It is also the first to meet one of the requirements defined on the roadmap for redefining the SI unit of the second: Measurements of frequency ratios with relative total measurement uncertainties below 5 × 10−18. The determination of the absolute frequency results in an uncertainty of 1.3 × 10−16 for the 1S0 ↔ 3P0 transition in 115In+, which is limited by that of the cesium fountains. The results obtained summarized: ν115In+ ν171Yb+(E3) =1.973 773 591 557 215 788(8) ν115In+ ν87Sr =2.952 748 749 874 860 781(27) ν115In+ =1 267 402 452 901 038.87(16) Hz
A multi-ion optical clock with 5×10−19\mathbf{5 \times 10^{-19}}5×10−19 uncertainty
Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below 1×10−181\times10^{-18}1×10−18. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of 5.3×10−195.3\times10^{-19}5.3×10−19 and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the 10−2010^{-20}10−20-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of 0.6926711632159660405(20)0.6926711632159660405(20)0.6926711632159660405(20), with a statistical uncertainty of 0.9×10−180.9\times10^{-18}0.9×10−18 and a combined uncertainty of 2.9×10−182.9\times 10^{-18}2.9×10−18. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.