Atomic clocks with cold atoms play important roles in the field of fundamental physics as well as primary frequency standards. Operating such cold atom clocks in space paves the way for further exploration in fundamental physics, for example dark matter and general relativity. We developed a space cold atom clock (SCAC), which was launched into orbit with the Space Lab TG-2 in 2016. Before it deorbited with TG-2 in 2019, the SCAC had been working continuously for almost 3 years. During the period in orbit, many scientific experiments and engineering tests were performed. In this article, we summarize the principle, development and in-orbit results. These works provide the basis for construction of a space-borne time-frequency system in deep space.
Atomic clocks with cold atoms play important roles in the field of fundamental physics as well as primary frequency standards. Operating such cold atom clocks in space paves the way for further exploration in fundamental physics, for example dark matter and general relativity. We developed a space cold atom clock (SCAC), which was launched into orbit with the Space Lab TG-2 in 2016. Before it deorbited with TG-2 in 2019, the SCAC had been working continuously for almost 3 years. During the period in orbit, many scientific experiments and engineering tests were performed. In this article, we summarize the principle, development and in-orbit results. These works provide the basis for construction of a space-borne time-frequency system in deep space.
We report the initial test results of a rubidium ( 87 Rb) space cold atom clock (SCAC). The space-qualified 87 Rb SCAC is composed of the physical package, the optical bench, the microwave synthesizer and the control electronics. After the system is integrated, about 10 8 87 Rb cold atoms are captured by magneto-optical trap. The linewidth of the Ramsey fringe is about 10 Hz for the free evolution time of 50 ms on the ground, and the signal-to-noise ratio is measured to be larger than 300. We demonstrate a good medium-term fractional frequency stability of 1.5 × 10 −14 @1000 s in the closed-loop operation on the ground. The main effects of the noise on the stability are also presented, and the optimized operating parameter is analyzed for the operation of SCAC in the microgravity environment.
We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.
The technique of laser cooling of atoms gives an opportunity to improve the performance of atomic clocks by using laser-cooled atoms. The most successful cold atom clock, called the atomic fountain, is now widely used as the primary frequency standard in many labs. The cold atom clock for satellite applications, however, has not been reported so far due to special requirements of space applications. Here, we report the development of an engineering model of a satellite-borne cold atom clock, which satisfied all requirements of in-orbit operation. The core of the clock’s principle is the laser cooling of atoms by diffuse laser lights inside the microwave cavity. The structure of the physics package is presented, and its main parameters are also given. The principle and design of the optical bench are described. The initial test results are presented, and the possible improvements are also discussed.
Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
Abstract Atomic clocks based on laser-cooled atoms are widely used as primary frequency standards. Deploying such cold atom clocks (CACs) in space is foreseen to have many applications. Here we present tests of a CAC operating in space. In orbital microgravity, the atoms are cooled, trapped, launched, and finally detected after being interrogated by a microwave field using the Ramsey method. Perturbing influences from the orbital environment on the atoms such as varying magnetic fields and the passage of the spacecraft through Earth’s radiation belt are also controlled and mitigated. With appropriate parameters settings, closed-loop locking of the CAC is realized in orbit and an estimated short-term frequency stability close to 3.0 × 10 −13 τ −1/2 has been attained. The demonstration of the long-term operation of cold atom clock in orbit opens possibility on the applications of space-based cold atom sensors.
Abstract We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.