Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

New Journal of Physics

From classical xenon fringes to hydrogen interferometry

Simon R Müller, P. Nédélec, Markus K. Oberthaler

Published Jun 11, 2020• 5 citations
Publisher

Abstract

Abstract A setup with three equally spaced transmission gratings can be described as a moiré deflectometer in the classical regime and as a Talbot–Lau interferometer in the quantum regime. We successfully operate such a three-grating device with a de Broglie wavelength span of more than two orders of magnitude (20 fm to 2.2 pm), employing different particles such as xenon, krypton, argon, helium, and hydrogen. With that we directly observe the transition from the classical description with fast xenon atoms, to the characteristic quantum behaviour of the Talbot–Lau interferometer using hydrogen atoms with correspondingly long de Broglie wavelength. The systematic study of the interference pattern gives important insights in the feasibility of a proton or antiproton interferometer with this setup.

DOI
10.1088/1367-2630/ab9bc1

Related papers

Asymmetric Talbot-Lau interferometry for inertial sensing

S. Sala, Marco G. Giammarchi, Stefano Olivares

We study in detail a peculiar configuration of the Talbot-Lau matter wave interferometer, characterized by unequal distances between the two diffraction gratings and the observation plane. We refer to this apparatus as the ``asymmetric Talbot-Lau setup.'' Particular attention is given to its capabilities as an inertial sensor for particle and atomic beams, also in comparison with the classical moir\'e deflectometer. The present paper is motivated by possible experimental applications in the context of antimatter wave interferometry, including the measurement of the gravitational acceleration of antimatter particles. Therefore we focus our analysis on the current state of the art. To support our findings, we have also performed numerical simulations of realistic particle beams with varying speed distributions.

arXiv:1601.06539•Physical Review A•Sep 21, 2016•12 citations

Molecule interference in the near-field Talbot regime

Carola Szewc

We show our progress in setting up a three grating near-field Talbot-Lau interferometer (TLI) for large molecules such as C60. The TLI is the preferred tool for showing the wave nature of large particles, as it accepts beams of poor spatial coherence and because of its scaling properties with increasing mass of the particles. The spatial coherence is prepared by the first grating, it can be seen as an array of many collimation slits. Our setup is highly flexible in terms of the possibility of changing most of the parameters (such as distances between the gratings and grating angles) from the outside of the UHV-chamber. As the interferometer and the molecular beam source are place in separate vacuum chambers, refilling the oven and adjusting the setup parameters to different molecules is possible without opening the interferometer chamber. This is necessary, as the pressure in the interferometer chamber has to be lower than 5.10-7 mbar in order to observe high interference contrast. The TLI is highly sensitive to vibrations, especially in the range of 1 kHz (the inverse time-of-flight of the molecules through the interferometer), which makes vibration damping crucial for the success of observing interference. We observed vibration amplitudes of up to 75 nm at low frequencies (158 Hz). Compared to the inverse time-of-flight of the molecules, these vibrations are not 'seen' by the molecules and are non-critical. We observed interference of C60 with a contrast of 27 %, by scanning the self-image of the diffraction grating. In the present setup, an interference contrast of 60 % should be observed with perfect alignment of the gratings. Time-of-flight measurements showed small modulations of the velocity distribution at for interference expected distances of 2.5 ms. We also show the possibility of reconstructing the Wigner distribution function out of measurements for the case of Talbot interference under experimental conditions.

•Sep 1, 2012•0 citations

Talbot-vonLau atom interferometry with cold slow potassium

John F. Clauser, Shifang Li

A dc hot thermal and an ac-modulated cold slow potassium beam copropagate and pass through an atom de Broglie--wave interferometer, consisting of a sequence of three microfabricated diffraction gratings. Talbot-vonLau interference fringes are formed and sensed by measuring transmission with a hot wire as a function of grating position. The hot beam produces diffraction-limited shadow Moir\'e fringes, while the longer de Broglie wavelength slow beam produces interference fringes with high visibility at the fifth and sixth spatial harmonics of the shadow Moir\'e fringes.

Physical Review A•Apr 1, 1994•154 citations

Matter-wave/atom interferometry

John F. Clauser, Shifang Li

Although interferometry's earliest and most familiar use is with photons, the discovery of matter-wave (deBroglie-wave) interference for electrons demanded the development of quantum mechanics. Since then, matter-wave interferometry has been performed with neutrons, Cooper electron-pairs, and most recently, with whole atoms and diatomic molecules. This talk describes our recent high-flux atom interferometry experiments using the generalized Talbot-vonLau effect. Our interferometer consists of a sequence of three planar vacuum-slit diffraction gratings, microfabricated from silicon nitride membranes. DeBroglie-wave interference fringes are sensed by measuring the transmission of potassium atoms on a hot- wire as a function of grating relative position. Different spatial Fourier components (up to sixth) in the diffraction pattern are resonant in the interferometer at different atomic velocities (i.e., at different wavelengths). When a laser cooled slow atomic beam is incident, various different diffraction patterns are observed as a function of atomic velocity. In an alternative `Heisenberg Microscope' configuration an incident thermal beam produces a velocity average over different fringe Fourier components. AC modulated weak laser light passing through the interferometer interacts selectively with atoms at a specific velocity. The associated fringe pattern is then ac modulated and revealed by its selective destruction.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 12, 1994•0 citations

Results of atom-interferometry experiments with potassium

John F. Clauser, Matthias Reinsch, Shaofan Li

Results of high flux atom interferometry experiments with potassium in generalized Talbot-vonLau configurations are presented. The interferometer consists of a sequence of three planar vacuum slit diffraction gratings, microfabricated from silicon nitride membranes. Interference fringes are sensed by measuring the transmission of atoms on a hot-wire as a function of grating relative position. Different spatial Fourier components (up to fifth) in the diffraction pattern are resonant in the interferometer at different atomic velocities. When a laser cooled slow beam is incident, various different diffraction patterns are observed as a function of atomic velocity, selected via the tuning of D2 cooling lasers. In an alternative “Heisenberg Microscope” configuration an incident thermal beam produces a velocity average over different fringe Fourier components. Fringe patterns for each HFS component are revealed by their selective destruction by AC modulated weak Dl laser light passing through the interferometer near the middle grating. Since imaging of the fluorescent light could determine which slit an atom passes, the laser removes the fringe pattern contribution by Doppler shifted atoms at its wavelength. That contribution is thus AC modulated and detected. Shifts of the patterns by gravity and rotation are evident when the vacuum chamber is tilted.

Annual Meeting Optical Society of America•Jan 1, 1993•0 citations

Matter-Wave Interferometer for Large Molecules

Björn Brezger, Lucia Hackermüller, S. Uttenthaler +3 more

We demonstrate a near-field Talbot-Lau interferometer for C70 fullerene molecules. Such interferometers are particularly suitable for larger masses. Using three free-standing gold gratings of 1 microm period and a transversally incoherent but velocity-selected molecular beam, we achieve an interference fringe visibility of 40% with high count rate. Both the high visibility and its velocity dependence are in good agreement with a quantum simulation that takes into account the van der Waals interaction of the molecules with the gratings and are in striking contrast to a classical moiré model.

arXiv:quant-ph/0202158•Physical Review Letters•Feb 26, 2002•331 citations
Abstract A setup with three equally spaced transmission gratings can be described as a moiré deflectometer in the classical regime and as a Talbot–Lau interferometer in the quantum regime. We successfully operate such a three-grating device with a de Broglie wavelength span of more than two orders of magnitude (20 fm to 2.2 pm), employing different particles such as xenon, krypton, argon, helium, and hydrogen. With that we directly observe the transition from the classical description with fast xenon atoms, to the characteristic quantum behaviour of the Talbot–Lau interferometer using hydrogen atoms with correspondingly long de Broglie wavelength. The systematic study of the interference pattern gives important insights in the feasibility of a proton or antiproton interferometer with this setup.
We study in detail a peculiar configuration of the Talbot-Lau matter wave interferometer, characterized by unequal distances between the two diffraction gratings and the observation plane. We refer to this apparatus as the ``asymmetric Talbot-Lau setup.'' Particular attention is given to its capabilities as an inertial sensor for particle and atomic beams, also in comparison with the classical moir\'e deflectometer. The present paper is motivated by possible experimental applications in the context of antimatter wave interferometry, including the measurement of the gravitational acceleration of antimatter particles. Therefore we focus our analysis on the current state of the art. To support our findings, we have also performed numerical simulations of realistic particle beams with varying speed distributions.
We show our progress in setting up a three grating near-field Talbot-Lau interferometer (TLI) for large molecules such as C60. The TLI is the preferred tool for showing the wave nature of large particles, as it accepts beams of poor spatial coherence and because of its scaling properties with increasing mass of the particles. The spatial coherence is prepared by the first grating, it can be seen as an array of many collimation slits. Our setup is highly flexible in terms of the possibility of changing most of the parameters (such as distances between the gratings and grating angles) from the outside of the UHV-chamber. As the interferometer and the molecular beam source are place in separate vacuum chambers, refilling the oven and adjusting the setup parameters to different molecules is possible without opening the interferometer chamber. This is necessary, as the pressure in the interferometer chamber has to be lower than 5.10-7 mbar in order to observe high interference contrast. The TLI is highly sensitive to vibrations, especially in the range of 1 kHz (the inverse time-of-flight of the molecules through the interferometer), which makes vibration damping crucial for the success of observing interference. We observed vibration amplitudes of up to 75 nm at low frequencies (158 Hz). Compared to the inverse time-of-flight of the molecules, these vibrations are not 'seen' by the molecules and are non-critical. We observed interference of C60 with a contrast of 27 %, by scanning the self-image of the diffraction grating. In the present setup, an interference contrast of 60 % should be observed with perfect alignment of the gratings. Time-of-flight measurements showed small modulations of the velocity distribution at for interference expected distances of 2.5 ms. We also show the possibility of reconstructing the Wigner distribution function out of measurements for the case of Talbot interference under experimental conditions.
A dc hot thermal and an ac-modulated cold slow potassium beam copropagate and pass through an atom de Broglie--wave interferometer, consisting of a sequence of three microfabricated diffraction gratings. Talbot-vonLau interference fringes are formed and sensed by measuring transmission with a hot wire as a function of grating position. The hot beam produces diffraction-limited shadow Moir\'e fringes, while the longer de Broglie wavelength slow beam produces interference fringes with high visibility at the fifth and sixth spatial harmonics of the shadow Moir\'e fringes.
Although interferometry's earliest and most familiar use is with photons, the discovery of matter-wave (deBroglie-wave) interference for electrons demanded the development of quantum mechanics. Since then, matter-wave interferometry has been performed with neutrons, Cooper electron-pairs, and most recently, with whole atoms and diatomic molecules. This talk describes our recent high-flux atom interferometry experiments using the generalized Talbot-vonLau effect. Our interferometer consists of a sequence of three planar vacuum-slit diffraction gratings, microfabricated from silicon nitride membranes. DeBroglie-wave interference fringes are sensed by measuring the transmission of potassium atoms on a hot- wire as a function of grating relative position. Different spatial Fourier components (up to sixth) in the diffraction pattern are resonant in the interferometer at different atomic velocities (i.e., at different wavelengths). When a laser cooled slow atomic beam is incident, various different diffraction patterns are observed as a function of atomic velocity. In an alternative `Heisenberg Microscope' configuration an incident thermal beam produces a velocity average over different fringe Fourier components. AC modulated weak laser light passing through the interferometer interacts selectively with atoms at a specific velocity. The associated fringe pattern is then ac modulated and revealed by its selective destruction.
Results of high flux atom interferometry experiments with potassium in generalized Talbot-vonLau configurations are presented. The interferometer consists of a sequence of three planar vacuum slit diffraction gratings, microfabricated from silicon nitride membranes. Interference fringes are sensed by measuring the transmission of atoms on a hot-wire as a function of grating relative position. Different spatial Fourier components (up to fifth) in the diffraction pattern are resonant in the interferometer at different atomic velocities. When a laser cooled slow beam is incident, various different diffraction patterns are observed as a function of atomic velocity, selected via the tuning of D2 cooling lasers. In an alternative “Heisenberg Microscope” configuration an incident thermal beam produces a velocity average over different fringe Fourier components. Fringe patterns for each HFS component are revealed by their selective destruction by AC modulated weak Dl laser light passing through the interferometer near the middle grating. Since imaging of the fluorescent light could determine which slit an atom passes, the laser removes the fringe pattern contribution by Doppler shifted atoms at its wavelength. That contribution is thus AC modulated and detected. Shifts of the patterns by gravity and rotation are evident when the vacuum chamber is tilted.
We demonstrate a near-field Talbot-Lau interferometer for C70 fullerene molecules. Such interferometers are particularly suitable for larger masses. Using three free-standing gold gratings of 1 microm period and a transversally incoherent but velocity-selected molecular beam, we achieve an interference fringe visibility of 40% with high count rate. Both the high visibility and its velocity dependence are in good agreement with a quantum simulation that takes into account the van der Waals interaction of the molecules with the gratings and are in striking contrast to a classical moiré model.