Results of high flux atom interferometry experiments with potassium in generalized Talbot-vonLau configurations are presented. The interferometer consists of a sequence of three planar vacuum slit diffraction gratings, microfabricated from silicon nitride membranes. Interference fringes are sensed by measuring the transmission of atoms on a hot-wire as a function of grating relative position. Different spatial Fourier components (up to fifth) in the diffraction pattern are resonant in the interferometer at different atomic velocities. When a laser cooled slow beam is incident, various different diffraction patterns are observed as a function of atomic velocity, selected via the tuning of D2 cooling lasers. In an alternative “Heisenberg Microscope” configuration an incident thermal beam produces a velocity average over different fringe Fourier components. Fringe patterns for each HFS component are revealed by their selective destruction by AC modulated weak Dl laser light passing through the interferometer near the middle grating. Since imaging of the fluorescent light could determine which slit an atom passes, the laser removes the fringe pattern contribution by Doppler shifted atoms at its wavelength. That contribution is thus AC modulated and detected. Shifts of the patterns by gravity and rotation are evident when the vacuum chamber is tilted.
Results of high flux atom interferometry experiments with potassium in generalized Talbot-vonLau configurations are presented. The interferometer consists of a sequence of three planar vacuum slit diffraction gratings, microfabricated from silicon nitride membranes. Interference fringes are sensed by measuring the transmission of atoms on a hot-wire as a function of grating relative position. Different spatial Fourier components (up to fifth) in the diffraction pattern are resonant in the interferometer at different atomic velocities. When a laser cooled slow beam is incident, various different diffraction patterns are observed as a function of atomic velocity, selected via the tuning of D2 cooling lasers. In an alternative “Heisenberg Microscope” configuration an incident thermal beam produces a velocity average over different fringe Fourier components. Fringe patterns for each HFS component are revealed by their selective destruction by AC modulated weak Dl laser light passing through the interferometer near the middle grating. Since imaging of the fluorescent light could determine which slit an atom passes, the laser removes the fringe pattern contribution by Doppler shifted atoms at its wavelength. That contribution is thus AC modulated and detected. Shifts of the patterns by gravity and rotation are evident when the vacuum chamber is tilted.
Results of atom interferometry experiments in generalized Talbot-vonLau configurations are presented. AC modulated D2 light from diode lasers is counter-directed on a thermal potassium beam. A pA AC current of cold, slow potassium atoms is extracted through a slit in a heated mirror, transmitted through an interferometer, and ionized by a hotwire. The interferometer consists of a sequence of three planar vacuum slit diffraction gratings, microfabricated from silicon nitride membranes. Interference fringes form a Moire with the third grating and are sensed by measuring the transmission as a function of grating relative position. Different spatial Fourier components (up to 5th) in the diffraction pattern, resonant in the interferometer at different atomic velocities, may be selected via the tuning of the cooling lasers. Shifts of the patterns by gravity and rotation are evident when the vacuum chamber is tilted.
Although interferometry's earliest and most familiar use is with photons, the discovery of matter-wave (deBroglie-wave) interference for electrons demanded the development of quantum mechanics. Since then, matter-wave interferometry has been performed with neutrons, Cooper electron-pairs, and most recently, with whole atoms and diatomic molecules. This talk describes our recent high-flux atom interferometry experiments using the generalized Talbot-vonLau effect. Our interferometer consists of a sequence of three planar vacuum-slit diffraction gratings, microfabricated from silicon nitride membranes. DeBroglie-wave interference fringes are sensed by measuring the transmission of potassium atoms on a hot- wire as a function of grating relative position. Different spatial Fourier components (up to sixth) in the diffraction pattern are resonant in the interferometer at different atomic velocities (i.e., at different wavelengths). When a laser cooled slow atomic beam is incident, various different diffraction patterns are observed as a function of atomic velocity. In an alternative `Heisenberg Microscope' configuration an incident thermal beam produces a velocity average over different fringe Fourier components. AC modulated weak laser light passing through the interferometer interacts selectively with atoms at a specific velocity. The associated fringe pattern is then ac modulated and revealed by its selective destruction.
We present results of atom interferometry experiments in which spatial matter - wave interference is revealed by its selective destruction. A thermal potassium beam is transmitted through a velocity selective atom interferometer and detected. The interferometer is a sequence of three diffraction gratings. Interference fringes forming a Moire pattern with the third grating determine the transmission. The thermal beam produces a velocity average over different fringe Fourier components, each resonant in the interferometer at a different atomic velocity. AC modulated laser light passes through the interferometer, near the middle grating. Since imaging of the fluorescent light could be used to determine which slit an atom passes, the contribution to the fringe pattern by atoms at the laser`s Doppler shifted wavelength is removed. That component is thus AC modulated and detected. This {open_quotes}atom interference filter{close_quotes} resolves the K{sup 39} HFS.
A dc hot thermal and an ac-modulated cold slow potassium beam copropagate and pass through an atom de Broglie--wave interferometer, consisting of a sequence of three microfabricated diffraction gratings. Talbot-vonLau interference fringes are formed and sensed by measuring transmission with a hot wire as a function of grating position. The hot beam produces diffraction-limited shadow Moir\'e fringes, while the longer de Broglie wavelength slow beam produces interference fringes with high visibility at the fifth and sixth spatial harmonics of the shadow Moir\'e fringes.
Atom de Broglie--wave interference fringes are revealed by their selective destruction. A thermal potassium beam is transmitted through a Talbot-Lau atom interferometer. Different fringe Fourier components resonate in the interferometer at different atomic velocities. The thermal velocity distribution averages and washes out the high-frequency components. ac-modulated laser light passes through the interferometer, is scattered by atoms at one velocity, and destroys, and thereby reveals via the ac modulation, the associated high-frequency fringe contribution.
Atom interferometers have been successfully applied for precision measurements and the realization of basic gedanken experiments [1]. They consist of three or more atom optical elements to split, redirect, and recombine the motional state of the atoms. These elements are implemented either by freestanding microstructures or by light fields. For high precision applications, such as gyroscopes [2–5], a large throughput of the initial atomic flux is advantageous [6]. In order to efficiently use all atoms in an uncollimated thermal atomic beam, the ideal atom interferometer should produce equally spaced fringes for a wide range of transverse and longitudinal velocities. So called “white light” interferometers solve the problem for different longitudinal velocities by the recombination of only two velocity independent transverse momentum states at the output of the interferometer. Examples for this are the three-grating interferometer [7], operating with a transversely collimated beam, and the Raman interferometer [8]. Operation using a transversely uncollimated atomic beam can also be realized by the Raman interferometer and, for interferometers that do not require light, by the Talbot-Lau interferometer [9]. The latter, in contrast to Ref. [7], operates with three gratings in the Fresnel regime of matter wave diffraction. Since, in this case, many different momentum components build up the interference pattern, the typical length scale of the setup, the Talbot length, depends on the atomic velocity. The Talbot-Lau interferometer is, therefore, chromatic. In this work, we study a charged wire as the central element in an atom interferometer that requires only microstructures, operates in the Fresnel regime, and accepts, therefore, an uncollimated beam of atoms. At the same time, it has essentially white light character over the range of the atomic velocities in our thermal atomic beam. This makes future extensions of our approach based on microstructures potentially as powerful as, for example, the Raman interferometer gyroscope [5]. The attractive interaction between the induced dipole and the charged wire redirects the atomic trajectories to form a simple interferometer with two spatially separated paths. It can, therefore, also be used to measure the recently proposed topological phase shifts for moving electric dipoles [10–13].