Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Visualized Experiments

In Situ Measurement of Vacuum Window Birefringence using 25Mg+ Fluorescence

W. H. Yuan, Hongli Liu, Wenyu Wei, Z. Y. Ma, P. Hao, Z. Deng, Ke Deng, Jingxuan Zhang, Zheng-bing Lü

Published Jun 13, 2020• 0 citations
Publisher

Abstract

Accurate control of the polarization states of laser light is important in precision measurement experiments. In experiments involving the use of a vacuum environment, the stress-induced birefringence effect of the vacuum windows will affect the polarization states of laser light inside the vacuum system, and it is very difficult to measure and optimize the polarization states of the laser light in situ. The purpose of this protocol is to demonstrate how to optimize the polarization states of the laser light based on the fluorescence of ions in the vacuum system, and how to calculate the birefringence of vacuum windows based on azimuthal angles of external wave plates with Mueller matrix. The fluorescence of 25Mg+ ions induced by laser light that is resonant with the transition of |32P3/2,F = 4, mF = 4 → |32S1/2,F = 3, mF = 3 is sensitive to the polarization state of the laser light, and maximum fluorescence will be observed with pure circularly polarized light. A combination of half-wave plate (HWP) and quarter-wave plate (QWP) can achieve arbitrary phase retardation and is used for compensating the birefringence of the vacuum window. In this experiment, the polarization state of the laser light is optimized based on the fluorescence of 25Mg+ ion with a pair of HWP and QWP outside the vacuum chamber. By adjusting the azimuthal angles of the HWP and QWP to obtain maximum ion fluorescence, one can obtain a pure circularly polarized light inside the vacuum chamber. With the information on the azimuthal angles of the external HWP and QWP, the birefringence of the vacuum window can be determined.

DOI
10.3791/61175

Related papers

A simple method for in situ measurement of vacuum window birefringence

W. H. Yuan, Hongli Liu, W. Z. Wei +6 more

We present a simple method to measure the degrees of circular polarization (DoCP) of laser light inside a vacuum chamber and the birefringence of a vacuum window by detecting the fluorescence emitted by Doppler cooled ions in an ion trap. Imperfect laser polarization will cause ions to be pumped to the dark state which will decrease the fluorescence rates of the ions. With a simulation based on the rate equations of the relevant energy levels of 25Mg+ ions, we find that the fluorescence rate is sensitive to the DoCP of the laser. Based on the simulation result, we present a new method to optimize the DoCP of the laser inside the vacuum chamber by adjusting fast axis azimuthal angles of a half-wave plate and a quarter-wave plate outside the vacuum chamber. The laser light is optimized to be circularly polarized with an uncertainty of the DoCP of 7.8 × 10−5. With the obtained polarization information on both sides of the vacuum window and treating the vacuum window as an unknown wave plate, the phase delay and the fast axis azimuthal angle of the vacuum window can be determined in the form of Mueller matrix. The phase delay is determined to be 197.60(39)°, and the fast axis azimuthal angle is determined to be 104.00(5)°.

Review of Scientific Instruments•Nov 1, 2019•3 citations

Note: In situ measurement of vacuum window birefringence by atomic spectroscopy

Andreas Steffen, Wolfgang Alt, Maximilian Genske +3 more

We present an in situ method to measure the birefringence of a single vacuum window by means of microwave spectroscopy on an ensemble of cold atoms. Stress-induced birefringence can cause an ellipticity in the polarization of an initially linearly polarized laser beam. The amount of ellipticity can be reconstructed by measuring the differential vector light shift of an atomic hyperfine transition. Measuring the ellipticity as a function of the linear polarization angle allows us to infer the amount of birefringence Δn at the level of 10(-8) and identify the orientation of the optical axes. The key benefit of this method is the ability to separately characterize each vacuum window, allowing the birefringence to be precisely compensated in existing vacuum apparatuses.

arXiv:1308.4959•Review of Scientific Instruments•Dec 1, 2013•21 citations

Polarization compensation for a birefringent Fabry–Perot interferometer

Zaeil Kim, So Young Kim, Seung‐Koo Lee +3 more

We built a Fabry–Perot interferometer for an atom-trapping experiment and devised a procedure to characterize and compensate the birefringence coming from the mirrors. Our design of the mirror mounts is compatible with the ultrahigh vacuum environment and it allows easy and durable alignment. The mounts provide mechanical stability but at the expense of measurable stress-induced mirror reflection birefringence. We developed an intuitive but mathematically general theory to describe the interferometer birefringence. The theory allows us to measure the birefringence in a systematic way. It also provides us with a prescription to compensate it and to create desired polarization state inside the interferometer by using a pair of common wave plates. We successfully applied the procedure to our Fabry–Perot interferometer to demonstrate its usefulness.

Review of Scientific Instruments•Aug 1, 2004•6 citations

INTENSITY NOISE SQUEEZING OF LASER DIODE WITH INPHASE EXTERNAL WEAK FEEDBACK BY HALF WAVE PLATE

Ruifang Dong, Junxiang Zhang, Tiancai Zhang +4 more

Due to the birefringence effect of the quantum well laser and the collimating lens in a low temperature cryostat, the polarization of the output light was changed, therefore the photon number fluctuation of the output individual linearly polarized mode was increased. By compensating the birefringence with a quarter wave plate, and utilizing an inphase external weak feedback to laser diode laser by means of residuary reflection from the two surfaces of a half wave plate, we obtained the output light of 24mW with the photon number fluctuation 2.8dB below the Standard Quantum Limit at the pump current of 34.65mA.

Acta Physica Sinica•Jan 1, 2001•1 citation

Interferometric and Uhlmann phases of mixed polarization states

Alexei D. Kiselev, Vladimir V. Kesaev

In our investigation into the effects of the degree of polarization in modulation of partially polarized light, we assume general settings of the interferometry of partially polarized light waves and perform theoretical analysis of the geometric phases: the Uhlmann phase and the interferometric phase. We introduce the relative Uhlmann phase determined by the Uhlmann holonomies of interfering beams and show that the interferometric phase generalized to the case of nonunitary evolution can, similar to the Uhlmann phase, be cast into the holonomy defined form. By using the technique based on a two-arm Mach-Zehnder interferometer, two different dynamical regimes of light modulation are experimentally studied: (a) modulation of the input light by the rotating quarter-wave plate (QWP), and (b) modulation of the testing beam by a birefringent plate with electrically controlled anisotropy represented by the deformed-helix ferroelectric liquid-crystal (DHFLC) cell. In the setup with the rotating QWP, the interferometric phase is found to be equal to the relative Uhlmann phase. Experimental and theoretical results being in excellent agreement show both that this phase is an oscillating function of the QWP angle and increases with the degree of polarization. For modulation by the DHFLC cell, the data derived from our electro-optic measurements are fitted using the theory of the orientational Kerr effect in FLCs. This theory in combination with the results of fitting is used to evaluate electric field dependencies of the interferometric and the Uhlmann phases.

arXiv:1806.08980•Physical Review A•Sep 13, 2018•5 citations

Full polarization control of fiber-delivered light in a dilution refrigerator

Jason Phoenix, Louis Gaudreau, Marek Korkusiński +5 more

Birefringence in optical fibers poses a challenge to controllably delivering polarized light. Strain-induced birefringence caused by bends in the fiber, vibrations, or a large temperature gradient can significantly alter the polarization, making it particularly difficult to deliver polarization states to low-temperature environments by fiber. In this paper, we investigate the transmission of polarized light through a fiber and discuss a method we have developed for delivering arbitrarily polarized light to the base stage of a dilution refrigerator using a standard optical fiber. We have created a compact, cryogenic optical system to identify the polarization of the delivered light, while room-temperature waveplates and a mathematical fiber model are used to fully characterize and compensate for the fiber's birefringent effects. We show here that we are able to deliver horizontal, vertical, diagonal, anti-diagonal, right circular, and left circular polarization states to milli-Kelvin temperatures, with state fidelities of greater than 0.96 being achieved in all cases. Additionally, we demonstrate that we can deliver randomly selected elliptical states through a standard fiber to the refrigerator. This opens up new opportunities for fiber-based optical experiments using polarized light, such as quantum information experiments using quantum states encoded in the polarization of single photons.

Review of Scientific Instruments•Aug 1, 2020•6 citations
Accurate control of the polarization states of laser light is important in precision measurement experiments. In experiments involving the use of a vacuum environment, the stress-induced birefringence effect of the vacuum windows will affect the polarization states of laser light inside the vacuum system, and it is very difficult to measure and optimize the polarization states of the laser light in situ. The purpose of this protocol is to demonstrate how to optimize the polarization states of the laser light based on the fluorescence of ions in the vacuum system, and how to calculate the birefringence of vacuum windows based on azimuthal angles of external wave plates with Mueller matrix. The fluorescence of 25Mg+ ions induced by laser light that is resonant with the transition of |32P3/2,F = 4, mF = 4 → |32S1/2,F = 3, mF = 3 is sensitive to the polarization state of the laser light, and maximum fluorescence will be observed with pure circularly polarized light. A combination of half-wave plate (HWP) and quarter-wave plate (QWP) can achieve arbitrary phase retardation and is used for compensating the birefringence of the vacuum window. In this experiment, the polarization state of the laser light is optimized based on the fluorescence of 25Mg+ ion with a pair of HWP and QWP outside the vacuum chamber. By adjusting the azimuthal angles of the HWP and QWP to obtain maximum ion fluorescence, one can obtain a pure circularly polarized light inside the vacuum chamber. With the information on the azimuthal angles of the external HWP and QWP, the birefringence of the vacuum window can be determined.
We present a simple method to measure the degrees of circular polarization (DoCP) of laser light inside a vacuum chamber and the birefringence of a vacuum window by detecting the fluorescence emitted by Doppler cooled ions in an ion trap. Imperfect laser polarization will cause ions to be pumped to the dark state which will decrease the fluorescence rates of the ions. With a simulation based on the rate equations of the relevant energy levels of 25Mg+ ions, we find that the fluorescence rate is sensitive to the DoCP of the laser. Based on the simulation result, we present a new method to optimize the DoCP of the laser inside the vacuum chamber by adjusting fast axis azimuthal angles of a half-wave plate and a quarter-wave plate outside the vacuum chamber. The laser light is optimized to be circularly polarized with an uncertainty of the DoCP of 7.8 × 10−5. With the obtained polarization information on both sides of the vacuum window and treating the vacuum window as an unknown wave plate, the phase delay and the fast axis azimuthal angle of the vacuum window can be determined in the form of Mueller matrix. The phase delay is determined to be 197.60(39)°, and the fast axis azimuthal angle is determined to be 104.00(5)°.
We present an in situ method to measure the birefringence of a single vacuum window by means of microwave spectroscopy on an ensemble of cold atoms. Stress-induced birefringence can cause an ellipticity in the polarization of an initially linearly polarized laser beam. The amount of ellipticity can be reconstructed by measuring the differential vector light shift of an atomic hyperfine transition. Measuring the ellipticity as a function of the linear polarization angle allows us to infer the amount of birefringence Δn at the level of 10(-8) and identify the orientation of the optical axes. The key benefit of this method is the ability to separately characterize each vacuum window, allowing the birefringence to be precisely compensated in existing vacuum apparatuses.
We built a Fabry–Perot interferometer for an atom-trapping experiment and devised a procedure to characterize and compensate the birefringence coming from the mirrors. Our design of the mirror mounts is compatible with the ultrahigh vacuum environment and it allows easy and durable alignment. The mounts provide mechanical stability but at the expense of measurable stress-induced mirror reflection birefringence. We developed an intuitive but mathematically general theory to describe the interferometer birefringence. The theory allows us to measure the birefringence in a systematic way. It also provides us with a prescription to compensate it and to create desired polarization state inside the interferometer by using a pair of common wave plates. We successfully applied the procedure to our Fabry–Perot interferometer to demonstrate its usefulness.
Due to the birefringence effect of the quantum well laser and the collimating lens in a low temperature cryostat, the polarization of the output light was changed, therefore the photon number fluctuation of the output individual linearly polarized mode was increased. By compensating the birefringence with a quarter wave plate, and utilizing an inphase external weak feedback to laser diode laser by means of residuary reflection from the two surfaces of a half wave plate, we obtained the output light of 24mW with the photon number fluctuation 2.8dB below the Standard Quantum Limit at the pump current of 34.65mA.
In our investigation into the effects of the degree of polarization in modulation of partially polarized light, we assume general settings of the interferometry of partially polarized light waves and perform theoretical analysis of the geometric phases: the Uhlmann phase and the interferometric phase. We introduce the relative Uhlmann phase determined by the Uhlmann holonomies of interfering beams and show that the interferometric phase generalized to the case of nonunitary evolution can, similar to the Uhlmann phase, be cast into the holonomy defined form. By using the technique based on a two-arm Mach-Zehnder interferometer, two different dynamical regimes of light modulation are experimentally studied: (a) modulation of the input light by the rotating quarter-wave plate (QWP), and (b) modulation of the testing beam by a birefringent plate with electrically controlled anisotropy represented by the deformed-helix ferroelectric liquid-crystal (DHFLC) cell. In the setup with the rotating QWP, the interferometric phase is found to be equal to the relative Uhlmann phase. Experimental and theoretical results being in excellent agreement show both that this phase is an oscillating function of the QWP angle and increases with the degree of polarization. For modulation by the DHFLC cell, the data derived from our electro-optic measurements are fitted using the theory of the orientational Kerr effect in FLCs. This theory in combination with the results of fitting is used to evaluate electric field dependencies of the interferometric and the Uhlmann phases.
Birefringence in optical fibers poses a challenge to controllably delivering polarized light. Strain-induced birefringence caused by bends in the fiber, vibrations, or a large temperature gradient can significantly alter the polarization, making it particularly difficult to deliver polarization states to low-temperature environments by fiber. In this paper, we investigate the transmission of polarized light through a fiber and discuss a method we have developed for delivering arbitrarily polarized light to the base stage of a dilution refrigerator using a standard optical fiber. We have created a compact, cryogenic optical system to identify the polarization of the delivered light, while room-temperature waveplates and a mathematical fiber model are used to fully characterize and compensate for the fiber's birefringent effects. We show here that we are able to deliver horizontal, vertical, diagonal, anti-diagonal, right circular, and left circular polarization states to milli-Kelvin temperatures, with state fidelities of greater than 0.96 being achieved in all cases. Additionally, we demonstrate that we can deliver randomly selected elliptical states through a standard fiber to the refrigerator. This opens up new opportunities for fiber-based optical experiments using polarized light, such as quantum information experiments using quantum states encoded in the polarization of single photons.