Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Development of necessary ion traps, vacuum and laser systems for photoionization, laser cooling and quantum state engineering of trapped strontium ions

Emil Kirilov

Published Jan 1, 2007• 0 citations
OpenAlex

Related papers

Laser cooling and trapping of strontium atoms for experiments towards precision measurements and frequency metrology

Chetan Vishwakarma

•Dec 1, 2020•0 citations

2-photon ionization and necessary laser and vacuum systems for experiments with trapped strontium ions

Emil Kirilov, Seth Putterman

We describe a efficient way to photoionize strontium atoms in a linear radio-frequency trap. We use a 2-photon second order process to excite the autoionization resonance (4d2 + 5p2) 1D2. A doubled pulsed Ti:Saphire laser system is used at 431nm to provide 100fsec pulses at 82Mhz. The fabrication of the laser systems for addressing the Sr+ transitions necessary for laser cooling and excitation of quantum jumps, vacuum system and ion trap structure are also described in detail. With the current setup a easy and repeatable trapping of linear ion chains is achieved at UHV pressures.

arXiv:0712.0222•Dec 3, 2007•0 citations

Research on Laser Cooling and Optical Lattice of Strontium Atoms

Tong Li

•Jul 3, 2026•0 citations

Towards Selective Two-step Photoionization of Ba Isotopes for Ba+ Ion Trap

Tamura Koji, Ogura Koichi, Shimada Hiroyuki +5 more

Cooling and trapping ion system is considered as a promising candidate for quantum information processor. Especially, by manipulating 133Ba+ ion, improved fidelity of qubit operation is expected, where selective 133Ba isotope introduction to the ion trap is required. Development of isotope selective loading system of Ba ion for the ion trap using the two-step laser photoionization is shown. For the excitation step (791 nm), the target isotope atom is photo-excited among other Ba isotopes based on their isotope shift. A tunable laser with a narrow spectral linewidth compared to the Ba isotope shift, was developed using an external cavity diode laser (ECDL). Mode-hop-free (MHF) scanning was achieved. For the second ionization step, a pulsed N2 laser was used. Both laser beams were combined using a mirror, focused with a lens, and introduced into a vacuum chamber. An atomic source was made by resistive heating, which can heat the source and generate atomic beam with sufficient vapor pressure and atomic density for the measurements. The system is under development and is prepared for the Ba atomic beam generation and laser photoionization experiments.

•Jul 4, 2024•0 citations

2-photon ionization for efficient seeding and trapping of strontium ions

Emil Kirilov, Seth Putterman

The European Physical Journal D•Jul 9, 2009•9 citations

Development of a Strontium-87 Ion Interferometer

Christopher Erickson

I present the construction of a low-velocity intense source (LVIS) of laser-cooled neutral strontium using permanent ring magnets. The LVIS consists of a magneto-optical trap from which cold strontium is extracted in a well-collimated beam. I also present the development and implementation of a full suite of low-noise, high-bandwidth laser control electronics including a microcontroller unit. This microcontroller remotely controls and monitors the current driver, temperature controller, and PID lock circuit for each diode laser simultaneously. The current driver output is accurate to within 2 micro-amps and repeatable to with a few nano-amps. The noise spectral density of the current driver hits a floor of 10^(-10) amps per root Hz at ~50 Hz and has a modulation bandwidth of ~50 MHz. The PID lock-circuit includes a scan-balancing option that we have used to scan an AR coated laser diode ~30 GHz mode-hop free. I describe the construction of an 80 mW frequency doubled 461 nm laser system using PPKTP for cooling and trapping neutral strontium in the LVIS. The LVIS, the electronics systems, and the 461 nm laser system represent major milestones on the way to producing a matter-wave interferometer using Sr-87 ions. The interferometer is based on an optical Raman transition between the hyperfine ground states of the Sr-87 ion. The ions will be produced by exciting the strontium LVIS beam to an auto-ionizing state in the continuum. In the interferometer two half-pi pulses of light and one pi pulse will be delivered to the ions to split and recombine their wave functions. I present calculations of the predicted sensitivity and a discussion of the possible applications. I present a method for locking a 407.8 nm laser to the 5s doublet S J=1/2 to 5p doublet P J=3/2 strontium ion transition in a neutral vapor. I present calculations for the necessary vacuum levels for the experiment and describe the preparation and assembly of the vacuum apparatus. The major vacuum system consists of two connected elastomer sealed chambers: one at 10^(-7) Torr and the other at 10^(-10) Torr separated by a region of low conductance. I present a Sr vapor cell constructed from standard CF fittings that allows the strontium to be heated to ~730 C, which can also be run as a thermal beam. I present a method for protecting the viewports on small-form alkali-earth vapor cells using lead or indium foil during the evaporation of oxide layers. Finally, I report on the current status of the experiment as well as detail future work on the apparatus.

•Jan 1, 2011•1 citation
We describe a efficient way to photoionize strontium atoms in a linear radio-frequency trap. We use a 2-photon second order process to excite the autoionization resonance (4d2 + 5p2) 1D2. A doubled pulsed Ti:Saphire laser system is used at 431nm to provide 100fsec pulses at 82Mhz. The fabrication of the laser systems for addressing the Sr+ transitions necessary for laser cooling and excitation of quantum jumps, vacuum system and ion trap structure are also described in detail. With the current setup a easy and repeatable trapping of linear ion chains is achieved at UHV pressures.
Cooling and trapping ion system is considered as a promising candidate for quantum information processor. Especially, by manipulating 133Ba+ ion, improved fidelity of qubit operation is expected, where selective 133Ba isotope introduction to the ion trap is required. Development of isotope selective loading system of Ba ion for the ion trap using the two-step laser photoionization is shown. For the excitation step (791 nm), the target isotope atom is photo-excited among other Ba isotopes based on their isotope shift. A tunable laser with a narrow spectral linewidth compared to the Ba isotope shift, was developed using an external cavity diode laser (ECDL). Mode-hop-free (MHF) scanning was achieved. For the second ionization step, a pulsed N2 laser was used. Both laser beams were combined using a mirror, focused with a lens, and introduced into a vacuum chamber. An atomic source was made by resistive heating, which can heat the source and generate atomic beam with sufficient vapor pressure and atomic density for the measurements. The system is under development and is prepared for the Ba atomic beam generation and laser photoionization experiments.
I present the construction of a low-velocity intense source (LVIS) of laser-cooled neutral strontium using permanent ring magnets. The LVIS consists of a magneto-optical trap from which cold strontium is extracted in a well-collimated beam. I also present the development and implementation of a full suite of low-noise, high-bandwidth laser control electronics including a microcontroller unit. This microcontroller remotely controls and monitors the current driver, temperature controller, and PID lock circuit for each diode laser simultaneously. The current driver output is accurate to within 2 micro-amps and repeatable to with a few nano-amps. The noise spectral density of the current driver hits a floor of 10^(-10) amps per root Hz at ~50 Hz and has a modulation bandwidth of ~50 MHz. The PID lock-circuit includes a scan-balancing option that we have used to scan an AR coated laser diode ~30 GHz mode-hop free. I describe the construction of an 80 mW frequency doubled 461 nm laser system using PPKTP for cooling and trapping neutral strontium in the LVIS. The LVIS, the electronics systems, and the 461 nm laser system represent major milestones on the way to producing a matter-wave interferometer using Sr-87 ions. The interferometer is based on an optical Raman transition between the hyperfine ground states of the Sr-87 ion. The ions will be produced by exciting the strontium LVIS beam to an auto-ionizing state in the continuum. In the interferometer two half-pi pulses of light and one pi pulse will be delivered to the ions to split and recombine their wave functions. I present calculations of the predicted sensitivity and a discussion of the possible applications. I present a method for locking a 407.8 nm laser to the 5s doublet S J=1/2 to 5p doublet P J=3/2 strontium ion transition in a neutral vapor. I present calculations for the necessary vacuum levels for the experiment and describe the preparation and assembly of the vacuum apparatus. The major vacuum system consists of two connected elastomer sealed chambers: one at 10^(-7) Torr and the other at 10^(-10) Torr separated by a region of low conductance. I present a Sr vapor cell constructed from standard CF fittings that allows the strontium to be heated to ~730 C, which can also be run as a thermal beam. I present a method for protecting the viewports on small-form alkali-earth vapor cells using lead or indium foil during the evaporation of oxide layers. Finally, I report on the current status of the experiment as well as detail future work on the apparatus.