Novel devices and methods for quantum resistance and impedance metrology

Martina Marzano

Published Jan 9, 2020• 0 citations
OpenAlex

Related papers

Impedance measurement technique for quantum systems

S. N. Shevchenko

arXiv:0708.0464•The European Physical Journal B•Jan 1, 2008•16 citations

Methods for electrical quantities metrology in cryogenic environments

Paolo Panetta

Quantum electrical metrology relies extensively on cryogenic phenomena, most notably the Josephson and quantum Hall effects, which provide the foundations of modern voltage and resistance standards. At the same time, the rapid development of superconducting electronics and cryogenic quantum technologies has increased the demand for accurate and traceable electrical measurements performed directly at cryogenic temperatures. Limited cooling power, self-heating, imperfect thermalization, parasitic impedances, and long measurement lines make the characterization and uncertainty assessment of such measurements particularly challenging. This thesis addresses two complementary aspects of electrical metrology in cryogenic environments: the traceable determination of microwave power at the device reference plane and the characterization of both a device exhibiting quantized current through dual Shapiro steps and its measurement setup.

•Oct 14, 2026•0 citations

Influence of the Josephson junction on the impedance and noise of a resistive superconductive quantum interference device

Robert J. Soulen, William E. Fogle, Jack H. Colwell +2 more

The impedance and noise of a resistive superconductive quantum interference device (R-SQUID) have been measured as a function of the dc and rf currents applied to it. The Josephson junction was adjustable so that data were also taken for several values of the junction critical current. The results were compared with the predictions of a resistively shunted junction (RSJ) model which takes into account the influence of the Josephson junction on the impedance and noise. The agreement was found to be quite good and demonstrates that the noise in the circuit is well understood. Use of the R-SQUID as a noise thermometer below 1 K is assessed in terms of corrections due to the RSJ model. It is demonstrated how the dc and rf currents may be adjusted so that the total noise of the R-SQUID is reduced to within 0.1% of the Johnson noise generated by the resistor alone. Under these conditions, the R-SQUID may be used as a noise thermometer to determine thermodynamic temperature to this inaccuracy from 6 to 700 mK.

Journal of Applied Physics•Oct 15, 1993•4 citations

Quantum Metrology and Quantum Sensors

WORLD SCIENTIFIC eBooks•Jul 9, 2024•0 citations

Fast Josephson Arrays for Voltage and Impedance Metrology

Juha Hassel, Leif Grönberg, P. Helistö +3 more

We introduce an optimized Josephson double array generating two independent voltages up to 1.5V using only one microwave input. Such an array, combined with the quantum Hall resistance, can provide the basic traceability for an electricity metrology laboratory from DC voltage to capacitance. We describe the array and present preliminary experimental results from DC measurements. Extending the output voltage up to 10V is discussed

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•4 citations

Quantum-Enhanced Metrology and Sensing

David S. Simon

Undergraduate texts in physics•Jan 1, 2025•0 citations
Quantum electrical metrology relies extensively on cryogenic phenomena, most notably the Josephson and quantum Hall effects, which provide the foundations of modern voltage and resistance standards. At the same time, the rapid development of superconducting electronics and cryogenic quantum technologies has increased the demand for accurate and traceable electrical measurements performed directly at cryogenic temperatures. Limited cooling power, self-heating, imperfect thermalization, parasitic impedances, and long measurement lines make the characterization and uncertainty assessment of such measurements particularly challenging. This thesis addresses two complementary aspects of electrical metrology in cryogenic environments: the traceable determination of microwave power at the device reference plane and the characterization of both a device exhibiting quantized current through dual Shapiro steps and its measurement setup.
The impedance and noise of a resistive superconductive quantum interference device (R-SQUID) have been measured as a function of the dc and rf currents applied to it. The Josephson junction was adjustable so that data were also taken for several values of the junction critical current. The results were compared with the predictions of a resistively shunted junction (RSJ) model which takes into account the influence of the Josephson junction on the impedance and noise. The agreement was found to be quite good and demonstrates that the noise in the circuit is well understood. Use of the R-SQUID as a noise thermometer below 1 K is assessed in terms of corrections due to the RSJ model. It is demonstrated how the dc and rf currents may be adjusted so that the total noise of the R-SQUID is reduced to within 0.1% of the Johnson noise generated by the resistor alone. Under these conditions, the R-SQUID may be used as a noise thermometer to determine thermodynamic temperature to this inaccuracy from 6 to 700 mK.