Methods for electrical quantities metrology in cryogenic environments

Paolo Panetta

Published Oct 14, 2026• 0 citations
OpenAlex

Abstract

Quantum electrical metrology relies extensively on cryogenic phenomena, most notably the Josephson and quantum Hall effects, which provide the foundations of modern voltage and resistance standards. At the same time, the rapid development of superconducting electronics and cryogenic quantum technologies has increased the demand for accurate and traceable electrical measurements performed directly at cryogenic temperatures. Limited cooling power, self-heating, imperfect thermalization, parasitic impedances, and long measurement lines make the characterization and uncertainty assessment of such measurements particularly challenging. This thesis addresses two complementary aspects of electrical metrology in cryogenic environments: the traceable determination of microwave power at the device reference plane and the characterization of both a device exhibiting quantized current through dual Shapiro steps and its measurement setup.

Related papers

Cryogenic Characterization of a Superconductor Quantum-Based Microwave Reference Source for Communications and Quantum Information

Alírio Boaventura, Justus A. Brevik, Dylan Forrest Williams +6 more

We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.

IEEE Transactions on Applied Superconductivity•Oct 13, 2021•8 citations

Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator

Paolo Panetta, Andrea Celotto, Alessandro Alocco +7 more

Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.

physics.ins-detCross-listedarXiv:2607.12751•Jul 15, 2026•0 citations

Applications: Metrology

John C. Gallop, Ling Hao, Alain Rüfenacht

Metrology is the science of precision measurement of physical quantities and has developed a close relationship with superconductivity and superconducting materials, beginning with the discoveries of magnetic flux quantization and the Josephson effects in 1961 and 1962. Programmable Josephson voltage standard systems were first proposed and developed at NIST and are nowadays fully demonstrated in numerous metrology measurements and operated in liquid-cryogen-free refrigerators. A Josephson array device with growing applications to ac voltage metrology has emerged in recent years: the pulse-driven Josephson arbitrary waveform synthesizer. The use of superconductors in solenoids allows current densities to be much higher than for conventional conductors due to zero Joule heating. The Josephson effect has been applied to temperature measurement through the detection of Johnson noise using various superconducting junction-based technologies. The most recent application of Josephson technologies to temperature metrology involves the use of quantum-based reference noise-voltage waveforms synthesized by arrays of Josephson junctions.

CRC Press eBooks•May 17, 2022•0 citations

Device-Agnostic Microwave Noise Metrology for Nonlinear Cryogenic Quantum Devices

Andrea Celotto, Alessandro Alocco, Bernardo Galvano +6 more

Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.

quant-pharXiv:2605.28808•May 28, 2026•1 citation

Electrical metrology based on quantum technology: a review of current progress

Siyun Wang, Meimei Duan, Qing Yang Xu +5 more

The development of power system has put forward higher requirements for electrical metrology. However, the traditional measurement based on artefact has encountered a bottleneck due to its instability. In order to reduce the uncertainty of measurement, metrology based on quantum technology has been wildly studied. This paper introduces the principle of quantum voltage and two types of Josephson voltage standards, programmable Josephson voltage standards and AC Josephson voltage standards. The development and current progress of quantum voltage is introduced.

IEEE International Electrical and Energy Conference (CIEEC)•May 27, 2022•0 citations

Towards a quantum ampere with dual-Shapiro steps in ultrasmall Josephson junctions

Paolo Durandetto, Luca Fasolo, P. Panetta +2 more

Microwave-driven ultrasmall Josephson junctions integrated in high-impedance environments exhibit quantized current plateaus, dual of the Shapiro steps observed in conventional Josephson junctions. Dual Shapiro steps were found to agree with the theory in parts in 103, and research is now ongoing with the aim of increasing the plateau currents and robustness, favoring the adoption of dual Josephson devices as primary quantum current standards. This work presents the development of an experimental setup optimized to achieve accurate quantum current plateaus. The setup includes a dry dilution refrigerator equipped with properly filtered DC and microwave lines for the minimization of noise and interferences, targeting the traceable characterization of dual Shapiro steps with uncertainties down to the 10−6level.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations
Quantum electrical metrology relies extensively on cryogenic phenomena, most notably the Josephson and quantum Hall effects, which provide the foundations of modern voltage and resistance standards. At the same time, the rapid development of superconducting electronics and cryogenic quantum technologies has increased the demand for accurate and traceable electrical measurements performed directly at cryogenic temperatures. Limited cooling power, self-heating, imperfect thermalization, parasitic impedances, and long measurement lines make the characterization and uncertainty assessment of such measurements particularly challenging. This thesis addresses two complementary aspects of electrical metrology in cryogenic environments: the traceable determination of microwave power at the device reference plane and the characterization of both a device exhibiting quantized current through dual Shapiro steps and its measurement setup.
We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.
Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.
Metrology is the science of precision measurement of physical quantities and has developed a close relationship with superconductivity and superconducting materials, beginning with the discoveries of magnetic flux quantization and the Josephson effects in 1961 and 1962. Programmable Josephson voltage standard systems were first proposed and developed at NIST and are nowadays fully demonstrated in numerous metrology measurements and operated in liquid-cryogen-free refrigerators. A Josephson array device with growing applications to ac voltage metrology has emerged in recent years: the pulse-driven Josephson arbitrary waveform synthesizer. The use of superconductors in solenoids allows current densities to be much higher than for conventional conductors due to zero Joule heating. The Josephson effect has been applied to temperature measurement through the detection of Johnson noise using various superconducting junction-based technologies. The most recent application of Josephson technologies to temperature metrology involves the use of quantum-based reference noise-voltage waveforms synthesized by arrays of Josephson junctions.
Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.
The development of power system has put forward higher requirements for electrical metrology. However, the traditional measurement based on artefact has encountered a bottleneck due to its instability. In order to reduce the uncertainty of measurement, metrology based on quantum technology has been wildly studied. This paper introduces the principle of quantum voltage and two types of Josephson voltage standards, programmable Josephson voltage standards and AC Josephson voltage standards. The development and current progress of quantum voltage is introduced.
Microwave-driven ultrasmall Josephson junctions integrated in high-impedance environments exhibit quantized current plateaus, dual of the Shapiro steps observed in conventional Josephson junctions. Dual Shapiro steps were found to agree with the theory in parts in 103, and research is now ongoing with the aim of increasing the plateau currents and robustness, favoring the adoption of dual Josephson devices as primary quantum current standards. This work presents the development of an experimental setup optimized to achieve accurate quantum current plateaus. The setup includes a dry dilution refrigerator equipped with properly filtered DC and microwave lines for the minimization of noise and interferences, targeting the traceable characterization of dual Shapiro steps with uncertainties down to the 10−6level.