Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Soviet physics. Doklady

Measurement of brightness of light fluxes using vacuum fluctuations as a reference

G. Kh. Kitaeva, Alexander N. Penin, Victor V. Fadeev, Yu. A. Yanait

Published Jul 1, 1979• 9 citations
OpenAlex

Related papers

Effective brightness of zero-point fluctuations of the electromagnetic vacuum accompanying parametric scattering of light

O. N. Abroskina, G. K. Kitayeva, Alexander N. Penin

RpPhM•Jun 1, 1985•0 citations

Absolute brightness measurements in the terahertz frequency range using vacuum and thermal fluctuations as references

G. Kh. Kitaeva, P. V. Yakunin, Vladimir V. Kornienko +1 more

Applied Physics B•Feb 5, 2014•25 citations

Absolute measurements of radiation sources spectral brightness and detectors quantum efficiency

Alexander N. Penin, Давид Николаевич Клышко

In this paper we present schemes of experimental setups for the radiation spectral brightness measurements in the range of 0.6 - 5 (mu) for N varying from 10-1 to 102 (if, for example, (lambda) equals 1 (mu) , this range of N corresponds to the brightness temperature range from 6 (DOT) 103 to 106 K), and for photomultipliers quantum efficiency measurements in the range of 0.4 - 5 (mu) with a dynamical range 10 - 1012 photon/sec and accuracy not worse than 1%. The new measurement methods are based on the utilization of the parametric light scattering phenomenon which is a spontaneous decay of laser pump photons in correlated photon pairs in crystals with quadratic nonlinear susceptibility. The first of two methods allows measurement of the radiation spectral brightness N in absolute units ('photons per mode') in visible and infrared range. The quantity N is related to the energetic brightness spectral density B through the equation B equals (hc2/(lambda) 5)N, where h is the Plank constant, c - the light velocity, (lambda) - the wavelength. The method is absolute and does not require any reference source or detector of radiation. Quantum noise of a parametric down-convertor, caused by the zero vacuum fluctuations with an effective brightness Nvac equals 1 photon per mode, is the reference in this case. The second method concerns the quantum efficiency of photodetectors determination, and it is based on the connection between the statistics of photocurrent and the radiation which causes it. The parametric scattering is a unique source of rather intensive and directed radiation flow consisting of photon pairs. Such a flow can be used to determine the absolute quantum efficiency of photodetectors.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 1, 1991•1 citation

MEASUREMENT OF LIGHT-FLUX BRIGHTNESS USING VACUUM FLUCTUATIONS AS A REFERENCE

G. Kh. Kitaeva, A N Penin, Victor V. Fadeev +1 more

Доклады Академии наук•Jan 1, 1979•3 citations

V Fluctuations of Light Beams

L. Mandeļ

Progress in optics•Jan 1, 1963•121 citations

Ghost infrared spectroscopy with bright twin beams

Akira Kawai, Makoto Shoshin, Kazuki Hashimoto +1 more

Frequency-correlated light offers a route to mid-infrared (MIR) spectroscopy without direct spectral detection in the MIR. Previous MIR ghost spectroscopy has mainly relied on low-gain spontaneous parametric down-conversion (SPDC) and photon-pair coincidence measurements, where the limited photon flux has restricted acquisition times to longer than one minute. Here, we demonstrate ghost infrared spectroscopy using bright twin beams generated by high-gain parametric down-conversion (PDC). High-gain PDC amplifies vacuum fluctuations, producing a different pair of frequency-correlated random spectra in each pump pulse. This pulse-resolved stochastic emission is naturally matched to time-stretch detection, which records the spectrum of the correlated near-infrared telecom signal for every pulse, while the MIR idler is measured by bucket detection. Consequently, each pump pulse yields one paired projection measurement comprising a spectrally resolved reference and the corresponding bucket value. We reconstruct the transmission spectrum of a structured optical filter and the molecular vibrational absorption spectrum of liquid benzene near 3.3 um with millisecond-scale acquisition, in good agreement with Fourier-transform infrared spectroscopy. This reduces the acquisition time by four to five orders of magnitude compared with previous MIR ghost spectroscopy demonstrations. These results transform ghost spectroscopy from coincidence-based photon counting to high-flux analog correlation spectroscopy, establishing a practical architecture for high-speed computational infrared spectroscopy driven by a narrowband semiconductor laser.

arXiv:2608.30460•Aug 31, 2026•0 citations
In this paper we present schemes of experimental setups for the radiation spectral brightness measurements in the range of 0.6 - 5 (mu) for N varying from 10-1 to 102 (if, for example, (lambda) equals 1 (mu) , this range of N corresponds to the brightness temperature range from 6 (DOT) 103 to 106 K), and for photomultipliers quantum efficiency measurements in the range of 0.4 - 5 (mu) with a dynamical range 10 - 1012 photon/sec and accuracy not worse than 1%. The new measurement methods are based on the utilization of the parametric light scattering phenomenon which is a spontaneous decay of laser pump photons in correlated photon pairs in crystals with quadratic nonlinear susceptibility. The first of two methods allows measurement of the radiation spectral brightness N in absolute units ('photons per mode') in visible and infrared range. The quantity N is related to the energetic brightness spectral density B through the equation B equals (hc2/(lambda) 5)N, where h is the Plank constant, c - the light velocity, (lambda) - the wavelength. The method is absolute and does not require any reference source or detector of radiation. Quantum noise of a parametric down-convertor, caused by the zero vacuum fluctuations with an effective brightness Nvac equals 1 photon per mode, is the reference in this case. The second method concerns the quantum efficiency of photodetectors determination, and it is based on the connection between the statistics of photocurrent and the radiation which causes it. The parametric scattering is a unique source of rather intensive and directed radiation flow consisting of photon pairs. Such a flow can be used to determine the absolute quantum efficiency of photodetectors.
Frequency-correlated light offers a route to mid-infrared (MIR) spectroscopy without direct spectral detection in the MIR. Previous MIR ghost spectroscopy has mainly relied on low-gain spontaneous parametric down-conversion (SPDC) and photon-pair coincidence measurements, where the limited photon flux has restricted acquisition times to longer than one minute. Here, we demonstrate ghost infrared spectroscopy using bright twin beams generated by high-gain parametric down-conversion (PDC). High-gain PDC amplifies vacuum fluctuations, producing a different pair of frequency-correlated random spectra in each pump pulse. This pulse-resolved stochastic emission is naturally matched to time-stretch detection, which records the spectrum of the correlated near-infrared telecom signal for every pulse, while the MIR idler is measured by bucket detection. Consequently, each pump pulse yields one paired projection measurement comprising a spectrally resolved reference and the corresponding bucket value. We reconstruct the transmission spectrum of a structured optical filter and the molecular vibrational absorption spectrum of liquid benzene near 3.3 um with millisecond-scale acquisition, in good agreement with Fourier-transform infrared spectroscopy. This reduces the acquisition time by four to five orders of magnitude compared with previous MIR ghost spectroscopy demonstrations. These results transform ghost spectroscopy from coincidence-based photon counting to high-flux analog correlation spectroscopy, establishing a practical architecture for high-speed computational infrared spectroscopy driven by a narrowband semiconductor laser.