Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Absolute brightness measurements in the terahertz frequency range using vacuum and thermal fluctuations as references

G. Kh. Kitaeva, P. V. Yakunin, Vladimir V. Kornienko, Alexander N. Penin

Published Feb 5, 2014• 25 citations
Publisher
DOI
10.1007/s00340-014-5779-0

Related papers

Measurement of brightness of light fluxes using vacuum fluctuations as a reference

G. Kh. Kitaeva, Alexander N. Penin, Victor V. Fadeev +1 more

Soviet physics. Doklady•Jul 1, 1979•9 citations

Exploring quantum optics in the terahertz

Jérôme Faist

•Jun 18, 2018•0 citations

Absolute measurements of radiation sources spectral brightness and detectors quantum efficiency

Alexander N. Penin, Давид Николаевич Клышко

In this paper we present schemes of experimental setups for the radiation spectral brightness measurements in the range of 0.6 - 5 (mu) for N varying from 10-1 to 102 (if, for example, (lambda) equals 1 (mu) , this range of N corresponds to the brightness temperature range from 6 (DOT) 103 to 106 K), and for photomultipliers quantum efficiency measurements in the range of 0.4 - 5 (mu) with a dynamical range 10 - 1012 photon/sec and accuracy not worse than 1%. The new measurement methods are based on the utilization of the parametric light scattering phenomenon which is a spontaneous decay of laser pump photons in correlated photon pairs in crystals with quadratic nonlinear susceptibility. The first of two methods allows measurement of the radiation spectral brightness N in absolute units ('photons per mode') in visible and infrared range. The quantity N is related to the energetic brightness spectral density B through the equation B equals (hc2/(lambda) 5)N, where h is the Plank constant, c - the light velocity, (lambda) - the wavelength. The method is absolute and does not require any reference source or detector of radiation. Quantum noise of a parametric down-convertor, caused by the zero vacuum fluctuations with an effective brightness Nvac equals 1 photon per mode, is the reference in this case. The second method concerns the quantum efficiency of photodetectors determination, and it is based on the connection between the statistics of photocurrent and the radiation which causes it. The parametric scattering is a unique source of rather intensive and directed radiation flow consisting of photon pairs. Such a flow can be used to determine the absolute quantum efficiency of photodetectors.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 1, 1991•1 citation

A primary radiation standard based on quantum nonlinear optics

Lemieux, Samuel, Enno Giese, Robert Fickler +2 more

The black body remains the most prominent source of light for absolute radiometry. Its main alternative, synchrotron radiation, requires costly and large facilities. Quantum optics offers a new radiometric source: parametric down-conversion (PDC), a nonlinear optical process, in which pairwise photon correlations enable absolute calibration of photodetectors. Since the emission rate crucially depends on the brightness of the electromagnetic field, quantum-mechanical fluctuations of the vacuum7 can be seen as a seed of spontaneous PDC, and their amplitude is a natural radiometric standard. Thus, they allow for the calibration of the spectral radiance of light sources by measuring the ratio between seeded and unseeded PDC. Here, we directly use the frequency spectrum of the electromagnetic vacuum to trigger spontaneous PDC and employ the generated light to infer the spectral response of a spectrometer over a broad spectral range. Then, we deduce the absolute quantum efficiency from the spectral shape of PDC in the high-gain regime, without relying on a seed or reference detector. Our results compare well with the ones obtained with a reference lamp, demonstrating a promising primary radiation standard.

•Jan 1, 2019•0 citations

MEASUREMENT OF LIGHT-FLUX BRIGHTNESS USING VACUUM FLUCTUATIONS AS A REFERENCE

G. Kh. Kitaeva, A N Penin, Victor V. Fadeev +1 more

Доклады Академии наук•Jan 1, 1979•3 citations

Terahertz quantum optics with ultra-short pulses

Ileana-Cristina Benea-Chelmus

•Jan 1, 2018•0 citations
In this paper we present schemes of experimental setups for the radiation spectral brightness measurements in the range of 0.6 - 5 (mu) for N varying from 10-1 to 102 (if, for example, (lambda) equals 1 (mu) , this range of N corresponds to the brightness temperature range from 6 (DOT) 103 to 106 K), and for photomultipliers quantum efficiency measurements in the range of 0.4 - 5 (mu) with a dynamical range 10 - 1012 photon/sec and accuracy not worse than 1%. The new measurement methods are based on the utilization of the parametric light scattering phenomenon which is a spontaneous decay of laser pump photons in correlated photon pairs in crystals with quadratic nonlinear susceptibility. The first of two methods allows measurement of the radiation spectral brightness N in absolute units ('photons per mode') in visible and infrared range. The quantity N is related to the energetic brightness spectral density B through the equation B equals (hc2/(lambda) 5)N, where h is the Plank constant, c - the light velocity, (lambda) - the wavelength. The method is absolute and does not require any reference source or detector of radiation. Quantum noise of a parametric down-convertor, caused by the zero vacuum fluctuations with an effective brightness Nvac equals 1 photon per mode, is the reference in this case. The second method concerns the quantum efficiency of photodetectors determination, and it is based on the connection between the statistics of photocurrent and the radiation which causes it. The parametric scattering is a unique source of rather intensive and directed radiation flow consisting of photon pairs. Such a flow can be used to determine the absolute quantum efficiency of photodetectors.
The black body remains the most prominent source of light for absolute radiometry. Its main alternative, synchrotron radiation, requires costly and large facilities. Quantum optics offers a new radiometric source: parametric down-conversion (PDC), a nonlinear optical process, in which pairwise photon correlations enable absolute calibration of photodetectors. Since the emission rate crucially depends on the brightness of the electromagnetic field, quantum-mechanical fluctuations of the vacuum7 can be seen as a seed of spontaneous PDC, and their amplitude is a natural radiometric standard. Thus, they allow for the calibration of the spectral radiance of light sources by measuring the ratio between seeded and unseeded PDC. Here, we directly use the frequency spectrum of the electromagnetic vacuum to trigger spontaneous PDC and employ the generated light to infer the spectral response of a spectrometer over a broad spectral range. Then, we deduce the absolute quantum efficiency from the spectral shape of PDC in the high-gain regime, without relying on a seed or reference detector. Our results compare well with the ones obtained with a reference lamp, demonstrating a promising primary radiation standard.