Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Communications in Theoretical Physics

The Phase Sensitivities for Different Phase-Shift Configurations in an SU(1,1) Interferometer*

Fan Wang, Wei Zhong, Lan 澜 Zhou 周, Yu‐Bo Sheng

Published Dec 1, 2019• 1 citation
Publisher

Abstract

Abstract We theoretically study the phase sensitivities of two different phase-shift configurations in an SU(1,1) interferometer with coherent ⊗ squeezed vacuum states. According to quantum Cramér-Rao theorem, we analytically obtain the ultimate phase sensitivities for two types of phase shift accumulating in one- and two-arm. Compared with the case of one-arm phase shift, the model with phase shift encoding in both arms may provide a better sensitivity when the strength of squeezed vacuum state is large enough. Furthermore, we discuss the achievable sensitivities with the homodyne measurement by invoking of error-propagation formula. In addition, we study the effect of internal and outernal photon losses on the phase sensitivity of the SU(1,1) interferometer and find that the unbalanced interferometer is helpful to improve precision even with high external losses .

DOI
10.1088/0253-6102/71/12/1435

Related papers

Phase estimation of phase shifts in two arms for an SU(1,1) interferometer with coherent and squeezed vacuum states

Qian-Kun Gong, Dong Li, Chun-Hua Yuan +2 more

We theoretically present the quantum Cramér-Rao bounds (QCRB) of an SU(1,1) interferometer for Gaussian states input with and without the internal photonic losses. The phase shifts in the single arm and in the double arms are studied and the corresponding analytical expressions of quantum Fisher information with Gaussian input states are presented. Different from the traditional Mach-Zehnder interferometer, the QCRB of single arm case is slightly higher or lower than that of double arms case depending on the input states. With a fixed mean photon number and for pure Gaussian state input, the optimal sensitivity is achieved with a squeezed vacuum input in one mode and the vacuum input in the other. We compare the QCRB with the standard quantum limit and Heisenberg limit. In the case of small internal losses the QCRB can beat the standard quantum limit.

arXiv:1608.00389•Chinese Physics B•Aug 1, 2017•32 citations

Improving the phase sensitivity of an SU(1,1) interferometer with photon-added squeezed vacuum light

Lili Guo, Ya‐Fei Yu, Zhi‐Ming Zhang

We study the phase sensitivity of an SU(1,1) interferometer from two aspects, i.e., the phase estimation determined by the error propagation formula and that by the quantum Cramér-Rao bound (QCRB). The results show that the phase sensitivity by using the intensity detection reaches the sub-shot-noise limit with a coherent state and an m-photon-added squeezed vacuum state (m-PA-SVS) as inputs. The phase sensitivity gradually approaches the Heisenberg limit for increasing m, and the ultimate phase precision improves with the increase of m. In addition, the QCRB can be saturated by the intensity detection with inputting the m-PA-SVS.

Optics Express•Oct 24, 2018•49 citations

Enhancing phase sensitivity in a Mach-Zehnder interferometer with various detection schemes using SU(1,1) coherent states

Nour-Eddine Abouelkhir, Abdallah Slaoui, El Hassan Saidi +2 more

Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.

arXiv:2406.08007•Journal of the Optical Society of America B•Dec 23, 2024•18 citations

The Super Phase Sensitivity of an SU(1,1) Interferometer with a Two-Mode Squeezed Coherent State via Balanced Homodyne and Intensity Detection

Changlan Xu, Lei Wang, Shaoqiu Ke +2 more

We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.

Photonics•Mar 23, 2026•1 citation

Quantum optical metrology in the lossy SU(2) and SU(1,1) interferometers

Yang Gao

We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.

arXiv:1606.08966•Physical Review A•Aug 18, 2016•25 citations

Phase estimation via multi-photon subtraction inside the SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Youke Xu +3 more

Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.

arXiv:2311.14612•Physica Scripta•Jul 4, 2024•9 citations
Abstract We theoretically study the phase sensitivities of two different phase-shift configurations in an SU(1,1) interferometer with coherent ⊗ squeezed vacuum states. According to quantum Cramér-Rao theorem, we analytically obtain the ultimate phase sensitivities for two types of phase shift accumulating in one- and two-arm. Compared with the case of one-arm phase shift, the model with phase shift encoding in both arms may provide a better sensitivity when the strength of squeezed vacuum state is large enough. Furthermore, we discuss the achievable sensitivities with the homodyne measurement by invoking of error-propagation formula. In addition, we study the effect of internal and outernal photon losses on the phase sensitivity of the SU(1,1) interferometer and find that the unbalanced interferometer is helpful to improve precision even with high external losses .
We theoretically present the quantum Cramér-Rao bounds (QCRB) of an SU(1,1) interferometer for Gaussian states input with and without the internal photonic losses. The phase shifts in the single arm and in the double arms are studied and the corresponding analytical expressions of quantum Fisher information with Gaussian input states are presented. Different from the traditional Mach-Zehnder interferometer, the QCRB of single arm case is slightly higher or lower than that of double arms case depending on the input states. With a fixed mean photon number and for pure Gaussian state input, the optimal sensitivity is achieved with a squeezed vacuum input in one mode and the vacuum input in the other. We compare the QCRB with the standard quantum limit and Heisenberg limit. In the case of small internal losses the QCRB can beat the standard quantum limit.
We study the phase sensitivity of an SU(1,1) interferometer from two aspects, i.e., the phase estimation determined by the error propagation formula and that by the quantum Cramér-Rao bound (QCRB). The results show that the phase sensitivity by using the intensity detection reaches the sub-shot-noise limit with a coherent state and an m-photon-added squeezed vacuum state (m-PA-SVS) as inputs. The phase sensitivity gradually approaches the Heisenberg limit for increasing m, and the ultimate phase precision improves with the increase of m. In addition, the QCRB can be saturated by the intensity detection with inputting the m-PA-SVS.
Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.
We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.
We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.
Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.