Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Photonics Research

Experimental demonstration of full-field quantum optical coherence tomography

Zeferino Ibarra-Borja, Carlos Sevilla-Gutiérrez, Roberto Ramírez-Alarcón, Héctor Cruz-Ramírez, Alfred B. U’Ren

Published Dec 19, 2019• 39 citations
Publisher

Abstract

We present, to the best of our knowledge, the first implementation of full-field quantum optical coherence tomography (FF-QOCT). In our system, we are able to obtain full three-dimensional (3D) information about the internal structure of a sample under study by relying on transversely resolved Hong–Ou–Mandel (HOM) interferometry with the help of an intensified CCD (ICCD) camera. Our system requires a single axial scan, obtaining full-field transverse single-photon intensity in coincidence with the detection of the sibling photon for each value of the signal-idler temporal delay. We believe that this capability constitutes a significant step forward toward the implementation of QOCT as a practical biomedical imaging technique.

DOI
10.1364/prj.8.000051

Related papers

Quantum Optical Coherence Microscopy for Bioimaging Applications

Pablo Yepiz-Graciano, Zeferino Ibarra-Borja, Roberto Ramírez-Alarcón +4 more

Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of entangled photon pairs in the well-known Hong-Ou-Mandel interferometer. Despite its promise, the technique is far from being competitive with current classical OCT devices due to the long required acquisition times, derived from the low photon-pair emission rates. In this work, we, on the one hand, demonstrate a quantum optical coherence microscopy technique, based on full-field QOCT, which employs entangled collinear photon pairs in a Linnik interferometer designed to overcome some of the limitations of previous QOCT implementations, and, on the other hand, test it on representative samples, including glass layers with manufactured transverse patterns and metal-coated biological specimens. In our setup, while the idler photon is collected with a multimode fiber, the signal photon is detected by an intensified charge-coupled device camera, leading to full-field transverse reconstruction through a single-axial acquisition sequence. Interestingly, our setup permits concurrent OCT and QOCT trace acquisition, the former with greater counts and the latter with the benefit of quantum-conferred advantages. We hope that our current results will represent a significant step forward towards the actual applicability of QOCT, e.g., in clinical settings.

arXiv:2205.01292•Physical Review Applied•Sep 22, 2022•21 citations

Spectrally-resolved Hong-Ou-Mandel interferometry for Quantum-Optical Coherence Tomography

Pablo Yepiz-Graciano, Alí Angulo, Héctor Cruz Ramírez +2 more

We present the first frequency-domain implementation of quantum optical coherence tomography, which eliminates the need for axial scanning, thus significantly speeding up data acquisition.

Quantum Information and Measurement (QIM)•Jan 1, 2021•2 citations

Quantum-optical coherence tomography with collinear entangled photons

Dorilian Lopez-Mago, Lukáš Novotný

Quantum-optical coherence tomography (QOCT) combines the principles of classical OCT with the correlation properties of entangled photon pairs [Phys. Rev. A 65, 053817 (2002)]. The standard QOCT configuration is based on the Hong-Ou-Mandel interferometer, which uses entangled photons propagating in separate interferometer arms. This noncollinear configuration imposes practical limitations, e.g., misalignment due to drift and low signal-to-noise. Here, we introduce and implement QOCT based on collinear entangled photons. It makes use of a two-photon Michelson interferometer and offers several advantages, such as simplicity, robustness, and adaptability.

Optics Letters•Sep 25, 2012•36 citations

Phase-dependent quantum optical coherence tomography

Mayte Y. Li-Gómez, Taras Hrushevskyi, Kayla McArthur +3 more

Two-photon interference is a cornerstone of quantum optics, enabling imaging, sensing, and precision measurements that surpass classical limits. By harnessing the quantum interference of photon pairs, as demonstrated by the Hong-Ou-Mandel effect, this approach offers superior axial resolution and intrinsic dispersion cancellation, along with strong noise suppression arising from the precise temporal correlations between photons. Building on these principles, we present the theoretical framework and experimental realization of phase-dependent quantum optical coherence tomography (QOCT), a technique that employs phase-modulated two-photon interference for noninvasive morphological analysis of multilayered samples. We demonstrate that introducing controlled phase shifts to photon pairs in a Hong-Ou-Mandel interferometer effectively eliminates artifacts caused by reflections at different sample layers, thereby greatly improving the accuracy and reliability of QOCT measurements. This work advances the fundamental understanding and practical deployment of two-photon interference, overcoming a key limitation in applying QOCT to real-world applications such as biomedical imaging and materials characterization.

arXiv:2503.06772•Physical Review Research•Sep 19, 2025•4 citations

Quantum optical coherence tomography using three time-energy entangled photons

Dorilian Lopez-Mago, Arturo Burguete Lopez, Eernesto Campos

Quantum Optical Coherence Tomography can achieve a greater image resolution compared to its classical counterpart, due to the entanglement of the photon pairs. Following the idea that higher the number of entangled photons, higher the resolution, we study the physical underpinnings that appear when using photon triplets. Unlike the usual Hong-Ou-Mandel interferometer used for QOCT, a much simpler implementation in the form of a Michelson interferometer is used in this work. We find that axial resolution can be improved by a factor of four. Additionally, we provide the numerical method to reconstruct the image given the triple coincidence rate.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 13, 2016•0 citations

Quantum optical coherence tomography of a biological sample

Magued B. Nasr, Darryl P. Goode, Nam Nguyen +5 more

A number of nonclassical (quantum) sources of light have come to the fore in recent years [1], but few practical applications have emerged. One such application is quantum optical coherence tomography (QOCT) [2, 3], a fourth-order interferometric optical-sectioning scheme that makes use of frequency-entangled photon pairs generated via spontaneous optical parametric down-conversion (SPDC). A particular merit of QOCT is that it is inherently immune to group-velocity dispersion (GVD) by virtue of the frequency entanglement of the photon pairs [4]-[6]. Conventional optical coherence tomography (OCT) [7], in contrast, is a second-order interferometric scheme that provides high-resolution axial sectioning by employing ultra-broadband light. Unfortunately, however, this leads to GVD, which degrades resolution. Here we present the first experimental QOCT images of a biological sample: an onion-skin tissue coated with gold nanoparticles. Three-dimensional images are displayed in the form of transverse sections at different depths. The results reveal that QOCT is a viable biological imaging technique.

IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS)•Nov 1, 2008•4 citations
We present, to the best of our knowledge, the first implementation of full-field quantum optical coherence tomography (FF-QOCT). In our system, we are able to obtain full three-dimensional (3D) information about the internal structure of a sample under study by relying on transversely resolved Hong–Ou–Mandel (HOM) interferometry with the help of an intensified CCD (ICCD) camera. Our system requires a single axial scan, obtaining full-field transverse single-photon intensity in coincidence with the detection of the sibling photon for each value of the signal-idler temporal delay. We believe that this capability constitutes a significant step forward toward the implementation of QOCT as a practical biomedical imaging technique.
Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of entangled photon pairs in the well-known Hong-Ou-Mandel interferometer. Despite its promise, the technique is far from being competitive with current classical OCT devices due to the long required acquisition times, derived from the low photon-pair emission rates. In this work, we, on the one hand, demonstrate a quantum optical coherence microscopy technique, based on full-field QOCT, which employs entangled collinear photon pairs in a Linnik interferometer designed to overcome some of the limitations of previous QOCT implementations, and, on the other hand, test it on representative samples, including glass layers with manufactured transverse patterns and metal-coated biological specimens. In our setup, while the idler photon is collected with a multimode fiber, the signal photon is detected by an intensified charge-coupled device camera, leading to full-field transverse reconstruction through a single-axial acquisition sequence. Interestingly, our setup permits concurrent OCT and QOCT trace acquisition, the former with greater counts and the latter with the benefit of quantum-conferred advantages. We hope that our current results will represent a significant step forward towards the actual applicability of QOCT, e.g., in clinical settings.
Quantum-optical coherence tomography (QOCT) combines the principles of classical OCT with the correlation properties of entangled photon pairs [Phys. Rev. A 65, 053817 (2002)]. The standard QOCT configuration is based on the Hong-Ou-Mandel interferometer, which uses entangled photons propagating in separate interferometer arms. This noncollinear configuration imposes practical limitations, e.g., misalignment due to drift and low signal-to-noise. Here, we introduce and implement QOCT based on collinear entangled photons. It makes use of a two-photon Michelson interferometer and offers several advantages, such as simplicity, robustness, and adaptability.
Two-photon interference is a cornerstone of quantum optics, enabling imaging, sensing, and precision measurements that surpass classical limits. By harnessing the quantum interference of photon pairs, as demonstrated by the Hong-Ou-Mandel effect, this approach offers superior axial resolution and intrinsic dispersion cancellation, along with strong noise suppression arising from the precise temporal correlations between photons. Building on these principles, we present the theoretical framework and experimental realization of phase-dependent quantum optical coherence tomography (QOCT), a technique that employs phase-modulated two-photon interference for noninvasive morphological analysis of multilayered samples. We demonstrate that introducing controlled phase shifts to photon pairs in a Hong-Ou-Mandel interferometer effectively eliminates artifacts caused by reflections at different sample layers, thereby greatly improving the accuracy and reliability of QOCT measurements. This work advances the fundamental understanding and practical deployment of two-photon interference, overcoming a key limitation in applying QOCT to real-world applications such as biomedical imaging and materials characterization.
Quantum Optical Coherence Tomography can achieve a greater image resolution compared to its classical counterpart, due to the entanglement of the photon pairs. Following the idea that higher the number of entangled photons, higher the resolution, we study the physical underpinnings that appear when using photon triplets. Unlike the usual Hong-Ou-Mandel interferometer used for QOCT, a much simpler implementation in the form of a Michelson interferometer is used in this work. We find that axial resolution can be improved by a factor of four. Additionally, we provide the numerical method to reconstruct the image given the triple coincidence rate.
A number of nonclassical (quantum) sources of light have come to the fore in recent years [1], but few practical applications have emerged. One such application is quantum optical coherence tomography (QOCT) [2, 3], a fourth-order interferometric optical-sectioning scheme that makes use of frequency-entangled photon pairs generated via spontaneous optical parametric down-conversion (SPDC). A particular merit of QOCT is that it is inherently immune to group-velocity dispersion (GVD) by virtue of the frequency entanglement of the photon pairs [4]-[6]. Conventional optical coherence tomography (OCT) [7], in contrast, is a second-order interferometric scheme that provides high-resolution axial sectioning by employing ultra-broadband light. Unfortunately, however, this leads to GVD, which degrades resolution. Here we present the first experimental QOCT images of a biological sample: an onion-skin tissue coated with gold nanoparticles. Three-dimensional images are displayed in the form of transverse sections at different depths. The results reveal that QOCT is a viable biological imaging technique.