Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2205.01292 · Physical Review Applied

Quantum Optical Coherence Microscopy for Bioimaging Applications

Pablo Yepiz-Graciano, Zeferino Ibarra-Borja, Roberto Ramírez-Alarcón, Gerardo Gutierrez-Torres, Héctor Cruz-Ramírez, Dorilian Lopez-Mago, Alfred B. U’Ren

Published Sep 22, 2022• 21 citations
arXivHTMLPDF

Abstract

Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of entangled photon pairs in the well-known Hong-Ou-Mandel interferometer. Despite its promise, the technique is far from being competitive with current classical OCT devices due to the long required acquisition times, derived from the low photon-pair emission rates. In this work, we, on the one hand, demonstrate a quantum optical coherence microscopy technique, based on full-field QOCT, which employs entangled collinear photon pairs in a Linnik interferometer designed to overcome some of the limitations of previous QOCT implementations, and, on the other hand, test it on representative samples, including glass layers with manufactured transverse patterns and metal-coated biological specimens. In our setup, while the idler photon is collected with a multimode fiber, the signal photon is detected by an intensified charge-coupled device camera, leading to full-field transverse reconstruction through a single-axial acquisition sequence. Interestingly, our setup permits concurrent OCT and QOCT trace acquisition, the former with greater counts and the latter with the benefit of quantum-conferred advantages. We hope that our current results will represent a significant step forward towards the actual applicability of QOCT, e.g., in clinical settings.

DOI
10.1103/physrevapplied.18.034060

Related papers

Experimental demonstration of full-field quantum optical coherence tomography

Zeferino Ibarra-Borja, Carlos Sevilla-Gutiérrez, Roberto Ramírez-Alarcón +2 more

We present, to the best of our knowledge, the first implementation of full-field quantum optical coherence tomography (FF-QOCT). In our system, we are able to obtain full three-dimensional (3D) information about the internal structure of a sample under study by relying on transversely resolved Hong–Ou–Mandel (HOM) interferometry with the help of an intensified CCD (ICCD) camera. Our system requires a single axial scan, obtaining full-field transverse single-photon intensity in coincidence with the detection of the sibling photon for each value of the signal-idler temporal delay. We believe that this capability constitutes a significant step forward toward the implementation of QOCT as a practical biomedical imaging technique.

Photonics Research•Dec 19, 2019•39 citations

Quantum-optical coherence tomography with collinear entangled photons

Dorilian Lopez-Mago, Lukáš Novotný

Quantum-optical coherence tomography (QOCT) combines the principles of classical OCT with the correlation properties of entangled photon pairs [Phys. Rev. A 65, 053817 (2002)]. The standard QOCT configuration is based on the Hong-Ou-Mandel interferometer, which uses entangled photons propagating in separate interferometer arms. This noncollinear configuration imposes practical limitations, e.g., misalignment due to drift and low signal-to-noise. Here, we introduce and implement QOCT based on collinear entangled photons. It makes use of a two-photon Michelson interferometer and offers several advantages, such as simplicity, robustness, and adaptability.

Optics Letters•Sep 25, 2012•36 citations

Quantum optical coherence tomography of a biological sample

Magued B. Nasr, Darryl P. Goode, Nam Nguyen +5 more

A number of nonclassical (quantum) sources of light have come to the fore in recent years [1], but few practical applications have emerged. One such application is quantum optical coherence tomography (QOCT) [2, 3], a fourth-order interferometric optical-sectioning scheme that makes use of frequency-entangled photon pairs generated via spontaneous optical parametric down-conversion (SPDC). A particular merit of QOCT is that it is inherently immune to group-velocity dispersion (GVD) by virtue of the frequency entanglement of the photon pairs [4]-[6]. Conventional optical coherence tomography (OCT) [7], in contrast, is a second-order interferometric scheme that provides high-resolution axial sectioning by employing ultra-broadband light. Unfortunately, however, this leads to GVD, which degrades resolution. Here we present the first experimental QOCT images of a biological sample: an onion-skin tissue coated with gold nanoparticles. Three-dimensional images are displayed in the form of transverse sections at different depths. The results reveal that QOCT is a viable biological imaging technique.

IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS)•Nov 1, 2008•4 citations

Phase-dependent quantum optical coherence tomography

Mayte Y. Li-Gómez, Taras Hrushevskyi, Kayla McArthur +3 more

Two-photon interference is a cornerstone of quantum optics, enabling imaging, sensing, and precision measurements that surpass classical limits. By harnessing the quantum interference of photon pairs, as demonstrated by the Hong-Ou-Mandel effect, this approach offers superior axial resolution and intrinsic dispersion cancellation, along with strong noise suppression arising from the precise temporal correlations between photons. Building on these principles, we present the theoretical framework and experimental realization of phase-dependent quantum optical coherence tomography (QOCT), a technique that employs phase-modulated two-photon interference for noninvasive morphological analysis of multilayered samples. We demonstrate that introducing controlled phase shifts to photon pairs in a Hong-Ou-Mandel interferometer effectively eliminates artifacts caused by reflections at different sample layers, thereby greatly improving the accuracy and reliability of QOCT measurements. This work advances the fundamental understanding and practical deployment of two-photon interference, overcoming a key limitation in applying QOCT to real-world applications such as biomedical imaging and materials characterization.

arXiv:2503.06772•Physical Review Research•Sep 19, 2025•4 citations

Ultrahigh-Resolution Optical Coherence Tomography Using Quantum Entangled Photon Pairs

Masayuki Okano, Ryo Okamoto, Shigeki Takeuchi

Quantum technologies harness the intrinsic nature of quantum physics to beat limitations of classical methods. Recently, the application of quantum entanglement to metrology has attracted much attention. Quantum optical coherence tomography (QOCT) using two-photon interference between entangled photon pairs can overcome certain problems with classical optical coherence tomography (OCT). As the resolution of OCT becomes higher, degradation of the resolution due to dispersion becomes more critical. Here we show our work on the realization of 0.54 μm resolution two-photon interference, which surpasses the current record resolution 0.75 μm for OCT. In addition, the resolution for QOCT showed almost no change even when a 1-mm-thick water was inserted in the path of the interferometer. The results presented here represent a breakthrough for the realization of ultrahigh-resolution quantum metrology. Our work will open up possibilities for medical and biological applications.

The Review of Laser Engineering•Jan 1, 2016•0 citations

Cross-correlation scheme for quantum optical coherence tomography based on Michelson interferometer

Anna Romanova, Vadim Rodimin, Konstantin Katamadze

Quantum optical coherence tomography (QOCT) offers a simple way to cancel dispersion broadening in a sample while also providing twice the resolution compared to classical OCT. However, to achieve these advantages, a bright and broadband source of entangled photon pairs is required. A simple implementation uses collinear spontaneous parametric down-conversion in a Michelson interferometer (MI), yet this autocorrelation scheme suffers from parasitic terms and sensitivity to phase noise. Here, we introduce a cross-correlation MI-based QOCT that overcomes these drawbacks, significantly advancing QOCT toward practical applications.

arXiv:2505.08095•Physical Review Applied•Nov 24, 2025•1 citation
Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of entangled photon pairs in the well-known Hong-Ou-Mandel interferometer. Despite its promise, the technique is far from being competitive with current classical OCT devices due to the long required acquisition times, derived from the low photon-pair emission rates. In this work, we, on the one hand, demonstrate a quantum optical coherence microscopy technique, based on full-field QOCT, which employs entangled collinear photon pairs in a Linnik interferometer designed to overcome some of the limitations of previous QOCT implementations, and, on the other hand, test it on representative samples, including glass layers with manufactured transverse patterns and metal-coated biological specimens. In our setup, while the idler photon is collected with a multimode fiber, the signal photon is detected by an intensified charge-coupled device camera, leading to full-field transverse reconstruction through a single-axial acquisition sequence. Interestingly, our setup permits concurrent OCT and QOCT trace acquisition, the former with greater counts and the latter with the benefit of quantum-conferred advantages. We hope that our current results will represent a significant step forward towards the actual applicability of QOCT, e.g., in clinical settings.
We present, to the best of our knowledge, the first implementation of full-field quantum optical coherence tomography (FF-QOCT). In our system, we are able to obtain full three-dimensional (3D) information about the internal structure of a sample under study by relying on transversely resolved Hong–Ou–Mandel (HOM) interferometry with the help of an intensified CCD (ICCD) camera. Our system requires a single axial scan, obtaining full-field transverse single-photon intensity in coincidence with the detection of the sibling photon for each value of the signal-idler temporal delay. We believe that this capability constitutes a significant step forward toward the implementation of QOCT as a practical biomedical imaging technique.
Quantum-optical coherence tomography (QOCT) combines the principles of classical OCT with the correlation properties of entangled photon pairs [Phys. Rev. A 65, 053817 (2002)]. The standard QOCT configuration is based on the Hong-Ou-Mandel interferometer, which uses entangled photons propagating in separate interferometer arms. This noncollinear configuration imposes practical limitations, e.g., misalignment due to drift and low signal-to-noise. Here, we introduce and implement QOCT based on collinear entangled photons. It makes use of a two-photon Michelson interferometer and offers several advantages, such as simplicity, robustness, and adaptability.
A number of nonclassical (quantum) sources of light have come to the fore in recent years [1], but few practical applications have emerged. One such application is quantum optical coherence tomography (QOCT) [2, 3], a fourth-order interferometric optical-sectioning scheme that makes use of frequency-entangled photon pairs generated via spontaneous optical parametric down-conversion (SPDC). A particular merit of QOCT is that it is inherently immune to group-velocity dispersion (GVD) by virtue of the frequency entanglement of the photon pairs [4]-[6]. Conventional optical coherence tomography (OCT) [7], in contrast, is a second-order interferometric scheme that provides high-resolution axial sectioning by employing ultra-broadband light. Unfortunately, however, this leads to GVD, which degrades resolution. Here we present the first experimental QOCT images of a biological sample: an onion-skin tissue coated with gold nanoparticles. Three-dimensional images are displayed in the form of transverse sections at different depths. The results reveal that QOCT is a viable biological imaging technique.
Two-photon interference is a cornerstone of quantum optics, enabling imaging, sensing, and precision measurements that surpass classical limits. By harnessing the quantum interference of photon pairs, as demonstrated by the Hong-Ou-Mandel effect, this approach offers superior axial resolution and intrinsic dispersion cancellation, along with strong noise suppression arising from the precise temporal correlations between photons. Building on these principles, we present the theoretical framework and experimental realization of phase-dependent quantum optical coherence tomography (QOCT), a technique that employs phase-modulated two-photon interference for noninvasive morphological analysis of multilayered samples. We demonstrate that introducing controlled phase shifts to photon pairs in a Hong-Ou-Mandel interferometer effectively eliminates artifacts caused by reflections at different sample layers, thereby greatly improving the accuracy and reliability of QOCT measurements. This work advances the fundamental understanding and practical deployment of two-photon interference, overcoming a key limitation in applying QOCT to real-world applications such as biomedical imaging and materials characterization.
Quantum technologies harness the intrinsic nature of quantum physics to beat limitations of classical methods. Recently, the application of quantum entanglement to metrology has attracted much attention. Quantum optical coherence tomography (QOCT) using two-photon interference between entangled photon pairs can overcome certain problems with classical optical coherence tomography (OCT). As the resolution of OCT becomes higher, degradation of the resolution due to dispersion becomes more critical. Here we show our work on the realization of 0.54 μm resolution two-photon interference, which surpasses the current record resolution 0.75 μm for OCT. In addition, the resolution for QOCT showed almost no change even when a 1-mm-thick water was inserted in the path of the interferometer. The results presented here represent a breakthrough for the realization of ultrahigh-resolution quantum metrology. Our work will open up possibilities for medical and biological applications.
Quantum optical coherence tomography (QOCT) offers a simple way to cancel dispersion broadening in a sample while also providing twice the resolution compared to classical OCT. However, to achieve these advantages, a bright and broadband source of entangled photon pairs is required. A simple implementation uses collinear spontaneous parametric down-conversion in a Michelson interferometer (MI), yet this autocorrelation scheme suffers from parasitic terms and sensitivity to phase noise. Here, we introduce a cross-correlation MI-based QOCT that overcomes these drawbacks, significantly advancing QOCT toward practical applications.