We describe a new method to overcome the diffraction limit in astronomy, by amplification of photon wave packets. This method was demonstrated in theory, by computer simulation, and is now being experimentally tested.
In a previous article [Astron. Astrophys.561, A118 (2014)], we suggested a method to overcome the diffraction limit behind a telescope. We discuss and extend recent numerical simulations and test whether it is indeed possible to use photon amplification to enhance the angular resolution of a telescope or a microscope beyond the diffraction limit. An essential addition is the proposal to select events with an above-average ratio of stimulated to spontaneous photons. The analysis shows that the diffraction limit of a telescope is surpassed by a factor of 10 for an amplifier gain of 200, if the analysis is restricted to a tenth of the incoming astronomical photons. A gain of 70 is sufficient with a hundredth of the photons. More simulations must be performed to account for the bunching of spontaneous photons.
Heisenberg's uncertainty principle tells us that it’s impossible to determine simultaneously the position of a photon crossing a telescope's aperture as well as the angle of its momentum. A new technique suggests to overcome the diffraction limit via optical amplification. A number of entangled photons, created by amplification of a single photon, behaves as a single quantum system with respect to the uncertainty principle. Unfortunately, spontaneous emission contributes noise and negates the possible gain from this stimulated emission. The spontaneous photons guarantee the uncertainty principle. Thus the problem of low resolution is replaced by the problem of low SNR. The detection of spontaneous photons follows the same Poisson statistics in time and space. However, the stimulated photons are spatially and temporally coherent with the incoming photons. A pixel with additional hidden thermal signal will slightly modify the Poisson statistics, and only within the diffraction pattern of the photon packets. We characterise the average number of spontaneous photons in all pixels, and subtract it from the stimulated photons. This algorithm is applied on simulated detection events of an amplified signal. The reconstructed image is resolved beyond the limit of the same optical system in the absence of amplification. We produced a number of samples of a wide-band solid-state dye (DCM within PMMA), because the expected number of (stellar) photons is small, and a solid-state dye is easier to handle compared to a dye solution. Initial results with a white light source and a laser pump depict the parameters of the method.
The use of probabilistic amplification for astronomical imaging is discussed. Probabilistic single photon amplification has been theoretically proven and practically demonstrated in quantum optical laboratories. In astronomy it should allow to increase the angular resolution beyond the diffraction limit at the expense of throughput: not every amplification event is successful - unsuccessful events contain a large fraction of noise and need to be discarded. This article indicates the fundamental limit in the trade-off between gain in angular resolution and loss in throughput. The practical implementation of probabilistic amplification for astronomical imaging remains an open issue.
The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field.\n\nFor optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm.\n\nFor optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance\nfluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.