Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Journal of Lasers

Design of Microwave Cavity for in Situ Atom Detection Used in Space Cold Atom Clock

王新文 Xinwen Wang, Yuanci Gao, 赵剑波 Jianbo Zhao, 彭向凯 Xiangkai Peng, 任伟 Wei Ren, Jingfeng Xiang, 张镇 Zhen Zhang, Gongxun Dong, 刘亢亢 Kangkang Liu, Qiuzhi Qu, 刘亮 Liang Liu, 吕德胜 Lü Desheng

Published Jan 1, 2019• 0 citations
Publisher
DOI
10.3788/cjl201946.0901006

Related papers

Performance Analysis of Space Cold Atomic Clock Based on In-Situ Atomic Detection

彭向凯 Peng Xiangkai, 任伟 Ren Wei, 项静峰 Xiang Jingfeng +3 more

Acta Optica Sinica•Jan 1, 2019•1 citation

Design of the cold atom PHARAO space clock and initial test results

Philippe Laurent, Michel Abgrall, Ch. Jentsch +17 more

Applied Physics B•Aug 30, 2006•110 citations

New design of the compact cold atoms clock HORACE

François-Xavier Esnault, Sean Perrin, S. Trémine +5 more

In the compact cold atoms clock HORACE caesium atoms are successively laser cooled, submitted to a Ramsey microwave interrogation scheme and then detected by linear absorption directly inside the microwave cavity. The whole physics package and optical bench have been entirely redesigned to optimize such an in-situ detection and to perform a normalization scheme. Main efforts have been concentrated on technical issues such as magnetic shielding, microwave cavity polishing and tuning, use of fast mechanical switches to realize the optical sequence.

•Jan 1, 2006•6 citations

Development of a compact cold atom clock with a cylindrical cavity

Liang Liu, Hua-Dong Cheng, Peng Liu +5 more

Bulletin of the American Physical Society•Jun 9, 2015•0 citations

Cold atom microwave clock based on intracavity cooling in China space station

Siminda Deng, Wei Ren, Jingfeng Xiang +9 more

Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.

npj Microgravity•Jun 6, 2024•12 citations

Scheme for a compact cold-atom clock based on diffuse laser cooling in a cylindrical cavity

Peng Liu, Yan-Ling Meng, Jinyin Wan +5 more

We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of $24.5$ Hz with a contrast of $95.6%$ when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.

arXiv:1509.07650•Physical Review A•Dec 3, 2015•42 citations
In the compact cold atoms clock HORACE caesium atoms are successively laser cooled, submitted to a Ramsey microwave interrogation scheme and then detected by linear absorption directly inside the microwave cavity. The whole physics package and optical bench have been entirely redesigned to optimize such an in-situ detection and to perform a normalization scheme. Main efforts have been concentrated on technical issues such as magnetic shielding, microwave cavity polishing and tuning, use of fast mechanical switches to realize the optical sequence.
Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of 24.524.524.5 Hz with a contrast of 95.695.6%95.6 when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.