Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Japan Society of Applied Physics

Double-Flux-Quantum Amplifiers with magnetically-coupled parallel input terminals

Yuta Somei, Koki Yamazaki, Komei Higuchi, Hiroshi Shimada, Yoshinao Mizugaki

Published Jul 10, 2019• 0 citations
OpenAlex

Related papers

C-8-4 Double-Flux-Quantum Amplifier Excluding Magnetic Flux Bias Lines

Tomoki Watanabe, Yoshinao Mizugaki

Proceedings of the IEICE General Conference•Mar 1, 2016•0 citations

Redesigned of Double-Flux-Quantum Amplifier with a Single Line for Flux Biasing

Yuma Arai, Komei Higuchi, Hiroshi Shimada +1 more

The Japan Society of Applied Physics•Jul 21, 2017•0 citations

A double-flux-quantum amplifier with a single flux-biasing line

Yuma Arai, Yoshiaki Urai, Tomoki Watanabe +3 more

A Double-Flux-Quantum (DFQ) amplifier can multiply its input voltage with quantum accuracy using DFQ generation at under-damped Josephson junctions. We conducted research on digital-to-analogue converters that were implemented using DFQ amplifiers for metrological applications. Conventional DFQ amplifiers were usually operated using two flux-biasing lines. In this study, we redesigned the circuit layout to realize operation using a single flux-biasing line. We designed a new layout of a 20-fold DFQ amplifier and fabricated it using a 2.5-kA/cm 2 Nb/AlO x /Nb process. The measurement was performed in liquid He. The Single-Flux-Quantum (SFQ) pulse train was fed using an over-biasing method, and the input-output characteristics are acquired using an oscilloscope. When the magnetic flux bias current I fb1 was not supplied, the maximum input voltage V inmax was 68 μV, which was 4.2 times larger than the value of 17 μV that was observed in our previous study. V inmax was enhanced to 120 μV when we supplied an I fb1 of 1.00 mA.

Journal of Physics Conference Series•Jul 1, 2018•2 citations

Single flux quantum voltage amplifiers

Vladimir Golomidov, V. K. Kaplunenko, M. Khabipov +2 more

Cryogenics•Jan 1, 1992•4 citations

Enhanced operation frequencies of bipolar double-flux-quantum amplifiers fabricated using 10 kA cm −2 Nb/AlO x /Nb integration process

Yuta Somei, Hiroshi Shimada, Yoshinao Mizugaki

Abstract We have demonstrated digital-to-analog (D/A) operations using single-flux-quantum (SFQ) pulse-frequency modulation (PFM) D/A converters for future AC voltage standards. In this paper, for the improvement of SFQ-PFM D/A converters, we investigated a double-flux-quantum amplifier (DFQA) and a magnetically-coupling SFQ driver/receiver circuit (MC-SFQ-DR) fabricated using a 10 kA cm −2 Nb/AlO x /Nb integration process. The critical current density J c of 10 kA cm −2 was four times larger than that of the integration process we had used. A DFQA and an MC-SFQ-DR included unshunted Josephson junctions, and therefore, it was unclear if the high- J c process improved their performances. We measured test chips cooled in a liquid helium bath. The maximum input voltages for a +20 fold and a −20 fold DFQA were 147 and 126 μ V, for which the corresponding Josephson frequencies were 70.9 and 61.1 GHz. It was confirmed that the operation frequencies of the DFQAs and MC-SFQ-DR were improved approximately two-fold.

Japanese Journal of Applied Physics•May 24, 2021•6 citations

Quantum Amplifiers and Generators

Vitaliy V. Shtykov, Sergey M. Smolskiy

Springer eBooks•Jan 1, 2020•0 citations
A Double-Flux-Quantum (DFQ) amplifier can multiply its input voltage with quantum accuracy using DFQ generation at under-damped Josephson junctions. We conducted research on digital-to-analogue converters that were implemented using DFQ amplifiers for metrological applications. Conventional DFQ amplifiers were usually operated using two flux-biasing lines. In this study, we redesigned the circuit layout to realize operation using a single flux-biasing line. We designed a new layout of a 20-fold DFQ amplifier and fabricated it using a 2.5-kA/cm 2 Nb/AlO x /Nb process. The measurement was performed in liquid He. The Single-Flux-Quantum (SFQ) pulse train was fed using an over-biasing method, and the input-output characteristics are acquired using an oscilloscope. When the magnetic flux bias current I fb1 was not supplied, the maximum input voltage V inmax was 68 μV, which was 4.2 times larger than the value of 17 μV that was observed in our previous study. V inmax was enhanced to 120 μV when we supplied an I fb1 of 1.00 mA.
Abstract We have demonstrated digital-to-analog (D/A) operations using single-flux-quantum (SFQ) pulse-frequency modulation (PFM) D/A converters for future AC voltage standards. In this paper, for the improvement of SFQ-PFM D/A converters, we investigated a double-flux-quantum amplifier (DFQA) and a magnetically-coupling SFQ driver/receiver circuit (MC-SFQ-DR) fabricated using a 10 kA cm −2 Nb/AlO x /Nb integration process. The critical current density J c of 10 kA cm −2 was four times larger than that of the integration process we had used. A DFQA and an MC-SFQ-DR included unshunted Josephson junctions, and therefore, it was unclear if the high- J c process improved their performances. We measured test chips cooled in a liquid helium bath. The maximum input voltages for a +20 fold and a −20 fold DFQA were 147 and 126 μ V, for which the corresponding Josephson frequencies were 70.9 and 61.1 GHz. It was confirmed that the operation frequencies of the DFQAs and MC-SFQ-DR were improved approximately two-fold.