Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of the IEICE General Conference

C-8-4 Double-Flux-Quantum Amplifier Excluding Magnetic Flux Bias Lines

Tomoki Watanabe, Yoshinao Mizugaki

Published Mar 1, 2016• 0 citations
OpenAlex

Related papers

Redesigned of Double-Flux-Quantum Amplifier with a Single Line for Flux Biasing

Yuma Arai, Komei Higuchi, Hiroshi Shimada +1 more

The Japan Society of Applied Physics•Jul 21, 2017•0 citations

Double-Flux-Quantum Amplifiers with magnetically-coupled parallel input terminals

Yuta Somei, Koki Yamazaki, Komei Higuchi +2 more

The Japan Society of Applied Physics•Jul 10, 2019•0 citations

Design and Operation of a Double-Flux-Quantum Amplifier Excluding Flux Bias Lines

Yoshinao Mizugaki, Tomoki Watanabe

In addition to their fast switching with low power dissipation, precise voltage generation is a unique feature of single-flux-quantum (SFQ) circuits. This feature is attractive for realizing ac voltage standards consisting of SFQ-based digital-to-analog converters (DACs). Among several key components in SFQ-based DACs, a double-flux-quantum amplifier (DFQA) is a potential candidate to amplify the output voltage. In this paper, we present a redesigned DFQA without flux bias lines. We found a parameter set that provided wide bias margins and zero-flux-bias operation. Improved bias regions were numerically demonstrated, whereas a ±20-fold DFQA excluding flux biases was fabricated using Nb integration technology and tested in a liquid helium bath.

IEEE Transactions on Applied Superconductivity•May 10, 2016•2 citations

A double-flux-quantum amplifier with a single flux-biasing line

Yuma Arai, Yoshiaki Urai, Tomoki Watanabe +3 more

A Double-Flux-Quantum (DFQ) amplifier can multiply its input voltage with quantum accuracy using DFQ generation at under-damped Josephson junctions. We conducted research on digital-to-analogue converters that were implemented using DFQ amplifiers for metrological applications. Conventional DFQ amplifiers were usually operated using two flux-biasing lines. In this study, we redesigned the circuit layout to realize operation using a single flux-biasing line. We designed a new layout of a 20-fold DFQ amplifier and fabricated it using a 2.5-kA/cm 2 Nb/AlO x /Nb process. The measurement was performed in liquid He. The Single-Flux-Quantum (SFQ) pulse train was fed using an over-biasing method, and the input-output characteristics are acquired using an oscilloscope. When the magnetic flux bias current I fb1 was not supplied, the maximum input voltage V inmax was 68 μV, which was 4.2 times larger than the value of 17 μV that was observed in our previous study. V inmax was enhanced to 120 μV when we supplied an I fb1 of 1.00 mA.

Journal of Physics Conference Series•Jul 1, 2018•2 citations

Single flux quantum voltage amplifiers

Vladimir Golomidov, V. K. Kaplunenko, M. Khabipov +2 more

Cryogenics•Jan 1, 1992•4 citations

Redesigned Double-Flux-Quantum Amplifiers Fabricated Using 10-kA/cm 2 Nb

Yuta Somei, Koki Yamazaki, Hiroshi Shimada +1 more

The Japan Society of Applied Physics•Jan 28, 2020•0 citations
In addition to their fast switching with low power dissipation, precise voltage generation is a unique feature of single-flux-quantum (SFQ) circuits. This feature is attractive for realizing ac voltage standards consisting of SFQ-based digital-to-analog converters (DACs). Among several key components in SFQ-based DACs, a double-flux-quantum amplifier (DFQA) is a potential candidate to amplify the output voltage. In this paper, we present a redesigned DFQA without flux bias lines. We found a parameter set that provided wide bias margins and zero-flux-bias operation. Improved bias regions were numerically demonstrated, whereas a ±20-fold DFQA excluding flux biases was fabricated using Nb integration technology and tested in a liquid helium bath.
A Double-Flux-Quantum (DFQ) amplifier can multiply its input voltage with quantum accuracy using DFQ generation at under-damped Josephson junctions. We conducted research on digital-to-analogue converters that were implemented using DFQ amplifiers for metrological applications. Conventional DFQ amplifiers were usually operated using two flux-biasing lines. In this study, we redesigned the circuit layout to realize operation using a single flux-biasing line. We designed a new layout of a 20-fold DFQ amplifier and fabricated it using a 2.5-kA/cm 2 Nb/AlO x /Nb process. The measurement was performed in liquid He. The Single-Flux-Quantum (SFQ) pulse train was fed using an over-biasing method, and the input-output characteristics are acquired using an oscilloscope. When the magnetic flux bias current I fb1 was not supplied, the maximum input voltage V inmax was 68 μV, which was 4.2 times larger than the value of 17 μV that was observed in our previous study. V inmax was enhanced to 120 μV when we supplied an I fb1 of 1.00 mA.